manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IBM
  6. •
  7. Server
  8. •
  9. IBM 8639 - PC Server 325 Owner's manual

IBM 8639 - PC Server 325 Owner's manual

S84H-3049-00
IBM PC Servers
PC Server 325 - Type 8639
Hardware Maintenance
Manual Supplement
November 1996
Use this supplement with
the PC Servers
Hardware Maintenance Manual
IBM
Note
Before using this information and the product it
supports, be sure to read the general information
under “Notices” on page 139.
First (November 1996)
The following paragraph does not apply to the United
Kingdom or any country where such provisions are
inconsistent with local law: INTERNATIONAL
BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Some states do not allow disclaimer of
express or implied warranties in certain transactions,
therefore, this statement may not apply to you.
This publication could include technical inaccuracies or
typographical errors. Changes are periodically made to
the information herein; these changes will be incorporated
in new editions of the publication. IBM may make
improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time.
It is possible that this publication may contain reference to,
or information about, IBM products (machines and
programs), programming, or services that are not
announced in your country. Such references or
information must not be construed to mean that IBM
intends to announce such IBM products, programming, or
services in your country.
Requests for technical information about IBM products
should be made to your IBM reseller or IBM marketing
representative.
 Copyright International Business Machines
Corporation 1996. All rights reserved.
Note to U.S. Government users–Documentation related to
Restricted rights–Use, duplication, or disclosure is subject
to restrictions set forth in GSA ADP Schedule Contract
with IBM Corp.
ii PC Server HMM
About This Supplement
This supplement contains diagnostic information,
Symptom-to-FRU Index, service information, error codes,
error messages, and configuration information for the PC
Server 325 Type 8639.
This supplement should be used with the advanced
diagnostic tests and the information in the IBM
Personal
System/2 Hardware Maintenance Manual
(part number
83G8990, form number S52G-9971) and
IBM PC Servers
Hardware Maintenance Manual
(part number 70H0751,
form number S30H-2501 to troubleshoot problems
effectively.
Important
This manual is intended for trained servicers who are
familiar with IBM PC Server products.
Before servicing an IBM product, be sure to review
“Safety Information” on page 126.
iii
Related Publications
The following publications are available for IBM products.
For more information, contact IBM or an IBM Authorized
Dealer.
For Information About See Publication
PC Servers IBM PC Servers Hardware
Maintenance Manual
(S30H-2501)
PS/2 Computers IBM Personal System/2
Hardware Maintenance
Manual (S52G-9971)
PS/ValuePoint Computers IBM PS/ValuePoint
Hardware Maintenance
Service and Reference
(S61G-1423)
Laptop, Notebook, Portable,
and ThinkPad Computers
(L40, CL57, N45, N51,
P70/P75, ThinkPad 300,
350, 500, 510, 710T,
Expansion Unit, Dock I,
Dock II)
IBM Mobile Systems
Hardware Maintenance
Manual Volume 1
(S82G-1501)
ThinkPad Computers
(ThinkPad 340, 355, 360,
370, 700, 701, 720, 750,
755)
IBM Mobile Systems
Hardware Maintenance
Manual Volume 2
(S82G-1502)
ThinkPad Computers
(ThinkPad 365, 560, 760,
SelectaDock)
IBM Mobile Systems
Hardware Maintenance
Manual Volume 3
(S82G-1503)
Monitors (Displays)
(February 1993) IBM PS/2 Display HMM
Volume 1 (SA38-0053)
Monitors
(December 1993) IBM Color Monitor HMM
Volume 2 (S71G-4197)
IBM Monitors (P/G Series)
(July 1996) IBM Monitor HMM
Volume 3 (S52H-3679)
IBM 2248 Monitor
(February 1996) IBM Monitor HMM
Volume 4 (S52H-3739)
Disk Array technology
overview and using the IBM
RAID Configuration Program
Configuring Your Disk Array
booklet (S82G-1506)
Installation Planning for
Personal System/2
computers
Personal System/2
Installation Planning and
Beyond (G41G-2927)
Installation Planning for
Advanced Personal
System/2 Servers
Advanced PS/2 Servers
Planning and Selection
Guide (GG24-3927)
iv PC Server HMM
Contents
About This Supplement .............. iii
Related Publications . . . . . . . . . . . . . . . iv
General Checkout/Diagnostics QAPlus/PRO ... 1
General Checkout . . . . . . . . . . . . . . . . . 2
Diagnostics . . . . . . . . . . . . . . . . . . . . 3
PC Server 325 - Type 8639 ............ 13
Features . . . . . . . . . . . . . . . . . . . . . 16
Additional Service Information ........... 18
Locations . . . . . . . . . . . . . . . . . . . . . 88
Symptom-to-FRU Index . . . . . . . . . . . . . 107
Parts Listings . . . . . . . . . . . . . . . . . . 115
Parts Listing (PC Server Advanced Systems
Management Adapter) . . . . . . . . . . . . . 123
Related Service Information .......... 125
Safety Information . . . . . . . . . . . . . . . 126
Battery Notice . . . . . . . . . . . . . . . . . 131
Laser Compliance Statement .......... 132
Software/Hardware Mismatch Problems ..... 133
Undetermined Problems . . . . . . . . . . . . . 135
Problem Determination Tips ........... 136
Phone Numbers, U.S. and Canada ........ 137
Notices . . . . . . . . . . . . . . . . . . . . . 139
 Copyright IBM Corp. 1996 v
General Checkout/Diagnostics
QAPlus/PRO
General Checkout . . . . . . . . . . . . . . . . . 2
Diagnostics . . . . . . . . . . . . . . . . . . . . 3
Power-On Self-Test (POST) .......... 3
POST Beep Codes .............. 3
Test Programs . . . . . . . . . . . . . . . . . 3
Error Messages . . . . . . . . . . . . . . . . 4
Return Codes . . . . . . . . . . . . . . . . . 5
Using the Test Programs ............ 6
Program Navigation . . . . . . . . . . . . . 6
Intruder Alert . . . . . . . . . . . . . . . . 6
Using the First Letter of a Menu Choice . . 6
Using the Function Keys ......... 6
Command Line Options ......... 7
Viewing the Test Groups .......... 8
Scripting . . . . . . . . . . . . . . . . . . 8
Changing Logical Unit Numbers ....... 8
Test Group Specifications .......... 9
Starting the QAPlus/PRO Diagnostics Diskette 9
Module Testing Mode .......... 9
Running Selected Module Tests ..... 10
Running All Selected Modules ...... 10
Changing Selected Tests in Test Groups . 10
Running an Individual Test ........ 10
Stopping the Tests ............. 11
QAPlus/PRO Diagnostics Control Keys . . . 11
The following Maintenance Analysis Procedure (MAP) and
diagnostic information should be used to isolate problems
on servers that are supported by the QAPlus/PRO
Diagnostics test.
 Copyright IBM Corp. 1996 1
General Checkout
This general checkout procedure is for computers that are
supported by the QAPlus/PRO Diagnostics test.
Diagnostic error messages appear when a test program
finds a problem with a hardware option. For the test
programs to properly determine if a test
Passed
,
Failed
, or
Aborted
, the test programs check the error-return code at
test completion. (See “Return Codes” on page 5.)
General error messages appear if a problem or conflict is
found by an application program, the operating system, or
both. For an explanation of these messages, refer to the
information supplied with that software package.
Notes
1. If multiple error codes are displayed, diagnose
the first error code displayed.
2. If the computer reports a POST error, go to the
“Symptom-to-FRU Index” on page 107.
3. If the computer hangs and no error is displayed,
go to “Undetermined Problems” on page 135.
4. If a device cannot be selected from the Module
Test menu, that device might be defective.
001
– Power-off the computer and all external devices.
– Check all cables and power cords.
– Set all display controls to the middle position.
– Insert the QAPlus/PRO Diagnostics diskette into drive A.
– Power-on all external devices.
– Power-on the computer.
– Check for the following responses.
1. One beep.
2. Readable instructions or the Main Menu.
DID YOU RECEIVE THE CORRECT RESPONSES?
Yes No
002
Find the failure symptom in the “Symptom-to-FRU
Index” on page 107.
003
Run the Advanced Diagnostics Test. If necessary, refer to
“Diagnostics” on page 3.
If you receive an error, go to the“Symptom-to-FRU Index”
on page 107 .
2PC Server HMM
Diagnostics
The following tools are available to help identify and
resolve hardware-related problems:
Power-on self-test (POST)
POST Beep Codes
Test programs
Error messages
Diagnostics Diskette
Power-On Self-Test (POST)
Each time you power-on the system, it performs a series of
tests that check the operation of the system and some
options. This series of tests is called the
power-on
self-test
, or
POST
. POST does the following:
Checks some basic system-board operations
Checks the memory operation
Starts the video operation
Verifies that the diskette drives are working
Verifies that the hard disk drive is working
If the POST finishes without detecting any problems, a
single beep sounds and the first screen of the operating
system or application program appears.
If the POST detects a problem, an error message appears
on the screen. A single problem can cause several error
messages to appear. When you correct the cause of the
first error message, the other error messages probably will
not appear on the screen the next time you power-on the
system.
POST Beep Codes
The Power On Self-Test generates a beeping sound to
indicate successful completion of POST or to indicate that
the tests detect an error.
One beep and the appearance of text on the display
indicates successful completion of the POST. More than
one beep indicates that the POST detects an error.
Test Programs
The QAPlus/PRO test programs on the PC Server System
Board Diagnostic Diskette, developed by DiagSoft for
IBM, are the primary method of testing the PC Server. You
can use them to test the IBM components of the system
and some external devices. The amount of time required
to test all components depends on the number of
components. The more optional adapters and devices you
have attached to the system, the longer the testing takes.
Diagnostic programs from the QAPlus/PRO Main Menu
include the following features.
General Checkout/Diagnostics QAPlus/PRO 3
Feature Description
Quick
Check Identifies most problems associated with the
following major components:
System board
Hard disk drives
Diskette drives
CD-ROM drives
RAM
Serial and parallel ports
Video adapter
Printer
Keyboard
Mouse
Module
Test Allows you to:
Run groups of tests in batch
Specify parameters to use for each test
(for example, video modes, disk
cylinders, port addresses, and so on)
Specify the number of passes you want
to run (one to continuous)
Log the test results to a text or dBase
Format (DBF) file
Save all test settings for future use
View System Information
View the server's configuration
information. (For example, you can view
the IRQ/DMA assignments, memory
usage, device drivers, and so on.)
Select System Utilities
Format a diskette
Error Messages
Messages generated by the software—the operating
system or application programs—generally are text
messages, but they also can be numeric. Basically, there
are five types of error messages.
POST error messages
Diagnostic error messages
POST beep codes
Software generated messages.
Multiple messages
Error
Message Description
POST
Error
Messages
Displayed when POST finds problems with
the hardware or detects a change in the
hardware configuration.
POST
Beep
Codes
Sounds emitted from the speaker if POST
finds a problem. One beep indicates POST
completed successfully. Multiple beeps
indicate a problem was found by the POST.
Diagnostic
Error
Messages
Displayed when a test program finds a
problem with a hardware option.
4PC Server HMM
Error
Message Description
Software
Generated
Error
Messages
Displayed if a problem or conflict is found by
an application program, the operating system,
or both. For an explanation of these
messages, refer to the information supplied
with that software package.
Multiple
Messages The first error that occurs can cause
additional errors. Follow the suggested
action of the first error displayed. In this
case, the system displays more than one
error message. Always follow the suggested
action instructions for the
first
error message
displayed.
Return Codes
For the test programs to properly determine if a test
Passed
,
Failed
, or
Aborted
, the test programs check the
error-return code at test completion. To register the test
properly in the test log, the test programs must generate
one of the following return codes:
Return
Code Description
0 Indicates that the device passed its test.
1 Indicated that the device failed its test.
2 or
greater Indicates that the test stopped or was
aborted.
General Checkout/Diagnostics QAPlus/PRO 5
Using the Test Programs
The test programs provide advanced functions and utilities
for service or support professionals to troubleshoot even
the most difficult problems.
Program Navigation:
You can maneuver within the test programs by typing the
first letter of a menu choice, using the function keys, or
using command-line options.
Intruder Alert:
When you load QAPlus/PRO diagnostics, Intruder Alert
checks for damage to the Diagnostic Diskette. If a virus or
program alteration is detected, the diagnostic programs do
not load.
To suspend Intruder Alert and continue loading the
diagnostic programs, press Esc.
Using the First Letter of a Menu Choice
Throughout the test programs, pressing the first letter of an
option on a menu is the same as moving to that item with
the cursor and pressing Enter; however, this function is
not enabled on Test Group Screens.
Using the Function Keys
Use the following keys to maneuver throughout the test
programs:
Additional functions are available in the Test Module
Selection screen and the Test Group screen using the
following keys:
Keys Action
Enter Select an item, run the test module, or run
the test
Down
Arrow (↓)Moves the cursor down
Up Arrow
(↑)Moves the cursor up
F1 Calls up the appropriate Help information.
Use the up arrow key (↑) or the down arrow
key (↓) to scroll through the information.
Pressing F1 from within a Help screen
provides a help index from which you can
select different categories. One of the
important help categories is function key
usage. Pressing Esc exits Help and returns
to where you left off.
Esc Go back to the previous menu
Keys Action
Tab Move to test group (or move to parameters)
6PC Server HMM
Command Line Options
The following Command Line Options are available when
initially loading the diagnostic program from within its
directory of a DOS operating system. Loading
QAPlus/PRO from a DOS system command line allows
selected tests and options to run with minimum memory.
At a DOS operating system prompt, where the
QAPlus/PRO files reside, type QAPLPRO /XXX (where
XXX represents one or more of the following from the list
below) then, press Enter.
Keys Action
Spacebar Toggle modules on/off (or toggle tests on/off)
F2 View test results log
F10 Local menu
+Next logical unit number (for example, LUN 1,
LUN 2, and so on)
−Previous logical unit number
Command Action
/B&W The /B&W command line option forces the
program to load in Black and White
(Monochrome) mode, which is often more
readable on laptop computers.
/LOG=file The /LOG=file command line option directs
the test programs to start using a specified
Error Log file.
/INT10 The /INT10 command line option forces the
test programs to use the BIOS for screen
writes.
/OXXX The /OXXX command line option, where
XXX=test group (for example, MBD, MEM,
VID, HDU, FDU, KBD, COM, LPT, and so
on), omits the designated test group from
loading.
/OALL The /OALL command line option omits all
test groups from loading. This command
can be used in conjunction with the /IXXX
command.
/IXXX The /IXXX command line option, where
XXX=test group (for example, MBD, MEM,
VID, HDU, FDU, KBD, COM, LPT, and so
on), loads the designated test group for
testing. This option is helpful if you have
insufficient memory available to load all of
the test programs simultaneously.
/USRCONFIG
=file The /USERCONFIG=file command line
option tells the test programs to look for a
user diagnostic configuration file other than
the default USERDIAG.CFG.
General Checkout/Diagnostics QAPlus/PRO 7
Viewing the Test Groups
As you move the cursor bar up or down in the Test Module
Selection window, the right hand screen changes to show
the attributes, parameters, and the selected tests of the
corresponding Test Group. The diamond “♦” mark
indicates a module selected for testing.
The indicated attributes are characteristics of the selected
test module that are used by the test programs to
determine which tests to run or how to run selected tests.
Attributes are also used to limit the allowable range of
parameters (for example, – ending cylinder).
Parameters are values you select to establish the scope of
tests. For example, you can select Extended Memory
testing parameters and limit the testing to a specific range
of test blocks by specifying the starting and ending
memory block. This might be appropriate if prior
experience indicates that problems are likely to exist in a
specific area of memory. By selecting these limiting
parameters, you reduce memory testing time.
Scripting
Scripting allows you to select specific groups of tests,
testing parameters, and options. Your selection is saved
for later use as a test
Script
. To set up a test script, first
select all the appropriate test groups and specific tests you
want to run from the Module Testing section under
Diagnostics. You should also select appropriate testing
parameters and options. See “Program Navigation” on
page 6, for instructions to save a test script.
Changing Logical Unit Numbers
In some instances, you can have more than one logical
unit number (LUN) for a particular module. LUNs
represent individual devices within a test group or module.
For example, you might have two diskette drives or two
hard disk drives; or, you might have base and extended
memory installed in the computer. This configuration might
result in as many as two or three different LUNs in the
Memory Test Group.
Command Action
/SCRIPT
=file[,R] The /SCRIPT=file[,R] command line option
with the “,R” runs the selected script.
Please see “Scripting” on page 8 for a
description of scripting.
Note
You can use a “–” instead of a “/” as
the command line switch.
8PC Server HMM
From either the Module Test Menu or the Test Group
window, you can change to a different LUN (where
applicable) by pressing the plus (+) key (next LUN), or the
minus (−) key (previous LUN).
Test Group Specifications
In the upper-right-hand portion of the testing screen (or just
the upper portion if you switched to an individual test group
screen) are the specifications for the related test group.
Starting the QAPlus/PRO Diagnostics
Diskette
Note
The “PC Server System Board Diagnostic Diskette”
contains the QAPlus/PRO diagnostics for the PC
Server 325 Type 8639.
1. Insert the QAPlus/PRO Diagnostics Diskette into drive
A.
2. Power-on the computer.
3. When the QAPlus/PRO Diagnostics Main Menu is
displayed, press Ctrl+A.
4. Select Diagnostics; then, press Enter.
5. Follow the instructions that appear on the screen. If
an error is displayed, go to the “Symptom-to-FRU
Index” on page 107.
Module Testing Mode
If the test programs do not find a problem, or you want to
perform in-depth testing, the Module Testing mode
provides a method to run individual tests on a single
module. For example, you can run an individual test for
the diskette drive, or you can run groups of tests for
several modules.
In the Module Testing mode, you can define how many
times each test should run and how the test program
should log the errors.
To start the Module Testing mode:
1. Start the diagnostics diskette. See “Starting the
QAPlus/PRO Diagnostics Diskette.”
2. Select Diagnostic from the Main Menu.
3. Select Module Tests from the next menu.
4. Use the up and down arrow keys (↑ and ↓) to move
the highlight bar from one selection to the next.
5. Follow the instructions on the screen.
General Checkout/Diagnostics QAPlus/PRO 9
Note
As you scroll down the selection menu, the Test
Group window to the right changes to correspond to
the highlighted Module.
Running Selected Module Tests
To run all selected tests for a test group:
1. Use the up and down arrow keys (↑ and ↓) to move
the cursor to your selection.
2. Press Enter.
Note
A “♦” appears next to your selection.
Running All Selected Modules
To run all selected test modules:
1. Use the down arrow key (↓) to move the cursor to the
last choice, Run All Selected Modules.
2. Press Enter.
Note
A “♦” appears next to your selection.
Changing Selected Tests in Test Groups
To change selected tests in a Test Group:
1. In the Module Tests Menu, use the up and down
arrow keys (↑ and ↓) to move the cursor to your
selection.
2. Press Tab to move into the expanded Test Group
window.
3. Scroll to the test you want to select or deselect.
Attention
Items indicated by a directly adjacent “*” (red text
on color screens) are destructive tests.
4. Press the spacebar at the highlighted test to toggle
between select (indicated by a “♦”) and deselect.
Note
Pressing the first letter of a test does not activate
the test, unlike menu operation.
5. Press Esc to return to the Test Group.
6. Press Enter to run the selected tests.
Running an Individual Test
To run an individual test:
10 PC Server HMM
1. From the expanded Test Group, use the up and down
arrow keys (↑ and ↓) to move to the highlighted bar
to the test you want to run.
2. Press Enter to run the test.
Note
The results of the test appear in the
lower-right-hand Test Log window. Also, if you
enabled Test Logging, the results are recorded in
the Test Log.
3. When the test completes, press Esc to return to the
Test Group Menu.
Stopping the Tests
To stop running a specific test or stop testing after you
have started a test, press Esc while the test is running.
The test pauses at the first possible opportunity, and the
Skip/Abort Test Menu appears with the following options:
QAPlus/PRO Diagnostics Control Keys
The following is a list of the QAPlus/PRO Diagnostics
Control Keys, when used and a description of the
diagnostics response.
Option Action
Continue The test program begins testing where it left
off.
Skip to
next test The test program skips the current test, but
remaining tests for the selected Test Module
continue.
Skip to
next group The test program skips the remaining tests in
the current test group.
Abort all
tests The test program stops and returns to the
previous menu.
Control
Keys When Used Diagnostics Response
Ctrl+A Main Menu Allows you to select test from
the sub menus that are
highlighted with red letters.
Attention
If selected, these tests
will erase the information
stored on the diskette or
hard disk drive.
Up and
Down
Arrow
Keys
Main Menu
Module Test
Menu
Test Group
Menu
Highlights an item you want to
select.
General Checkout/Diagnostics QAPlus/PRO 11
Control
Keys When Used Diagnostics Response
Space
Bar Module Test
Menu
Test Group
Menu
Adds a diamond to the left of
the highlighted test. The test
will run when Run All
Selected is highlighted and
the Enter key is pressed.
Also removes the diamond to
the left of the item. The test
will not run when Run All
Selected is highlighted and
the Enter key is pressed.
Tab
Key Main Menu
Module Test
Menu
Selects the additional test for
the menu you are in.
+/−
Keys Test Group
Menu Selects additional test. The
LUN displayed on the top right
Test Group Menu shows which
test is selected and how and
remain (example LUN 1 of 2).
12 PC Server HMM
PC Server 325 - Type 8639
Features . . . . . . . . . . . . . . . . . . . . . 16
Additional Service Information ........... 18
Checkpoint Codes . . . . . . . . . . . . . . . 18
Configuration . . . . . . . . . . . . . . . . . 22
Adapters . . . . . . . . . . . . . . . . . . 22
Adapter Considerations . . . . . . . . . 22
Assigning Interrupt Levels .......... 23
EISA Configuration Diskette ......... 23
Backing Up the EISA Configuration Diskette 24
EISA Configuration Menu Selections . . . 24
Recording EISA Configuration Settings . . 25
Starting the EISA Configuration Diskette . 25
EISA Configuration Advanced Function . . 26
EISA, ISA, and PCI Adapters ........ 26
EISA or ISA Features and Options ...... 27
Files . . . . . . . . . . . . . . . . . . 27
Device Drivers . . . . . . . . . . . . . 29
Sample Applications . . . . . . . . . . . 29
Memory . . . . . . . . . . . . . . . . . . 29
PCI Features and Options .......... 30
Configuration Conflicts . . . . . . . . . . . . . 30
Changing the Software Configuration .... 31
Resolving Hardware Configuration Conflicts . 31
Resolving Software Configuration Conflicts . . 32
Configuration/Setup Utility Program ....... 33
Advanced Setup . . . . . . . . . . . . . . 33
Cache Control . . . . . . . . . . . . . . 34
ROM Shadowing . . . . . . . . . . . . 34
PCI Bus Control ............. 34
Devices and I/O Ports ........... 35
Diagnostic Programs . . . . . . . . . . . . . . 36
Option Diskettes . . . . . . . . . . . . . . 36
Installing Additional Test Programs ..... 36
USERDIAG.CFG Example . . . . . . . . . 38
Ethernet Controller . . . . . . . . . . . . . . . 39
Ethernet Controller Messages ......... 39
Novell NetWare Server ODI Driver Messages 40
Novell NetWare DOS ODI Driver Messages . 46
Novell NetWare OS/2 ODI Driver Messages . 52
NDIS 2.01 Driver Messages ......... 54
NDIS 3.0 Driver Messages ......... 57
Packet Driver Messages .......... 59
UNIX Messages . . . . . . . . . . . . . . 62
Ethernet Device Drivers ............ 66
Ethernet Diagnostics . . . . . . . . . . . . . . 67
Backing Up the Ethernet Diagnostic Diskette . 67
Starting the Ethernet Diagnostics ...... 67
Ethernet Ports . . . . . . . . . . . . . . . . . 67
Password . . . . . . . . . . . . . . . . . . . 68
Alarm/Wakeup Settings . . . . . . . . . . . 68
 Copyright IBM Corp. 1996 13
PC Server Advanced Systems Management
Adapter (FRU No. 76H3240) ......... 69
Installation Requirements . . . . . . . . . . 69
Resetting the Adapter and Clearing the
Configuration . . . . . . . . . . . . . . . 69
System and Adapter Configuration ...... 70
Configuration Considerations: . . . . . . 70
EISA Configuration Utility: ........ 71
Configuration/Setup Utility ISA Legacy
Resources: . . . . . . . . . . . . . . 71
Manual I/O Address and Interrupt
Assignment . . . . . . . . . . . . . . 72
Adapter Configuration: . . . . . . . . . 72
Device Driver Installation .......... 74
OS/2 Device Driver Installation ...... 74
Windows NT Device Driver Installation . . 74
Novell NetWare Device Driver Installation . 75
Adapter Cable to System Board Connections . 76
PC Server 325 ............... 76
PC Server 330 ............... 76
PC Server 704 ............... 77
External Power Control Unit Operation and
Indicators . . . . . . . . . . . . . . . . . 78
Power Supply . . . . . . . . . . . . . . . . . 80
SCSI Drives . . . . . . . . . . . . . . . . . . 82
Setting SCSI IDs .............. 82
Termination Requirements . . . . . . . . . 82
SCSISelect Utility Program ........... 83
Starting the SCSISelect Utility Program . . . 83
SCSISelect Utility Program Options ..... 83
Configure/View Host Adapter Settings .... 84
SCSI Disk Utilities ............. 84
Low-Level Format Program ......... 84
Starting the Low-Level Format Program . . 85
Specifications (PC Server 325 - Type 8639) . . . 86
System/Processor Board Replacement ..... 87
Symmetric Multiprocessors/Multiprocessing . . . 87
Locations . . . . . . . . . . . . . . . . . . . . . 88
Bezels . . . . . . . . . . . . . . . . . . . . 88
Controls and Status Indicators ......... 89
Covers . . . . . . . . . . . . . . . . . . . . 91
Doors . . . . . . . . . . . . . . . . . . . . . 91
Drawer Model Rails .............. 92
Drives . . . . . . . . . . . . . . . . . . . . . 92
Expansion Slots . . . . . . . . . . . . . . . . 93
Input/Output Connectors . . . . . . . . . . . . 94
Internal Drive Bays .............. 95
Keylock Assembly Exploded View ....... 96
Operator Panel and Cable ........... 97
Operator Panel Status Indicators ........ 98
Optional Microprocessor . . . . . . . . . . . 100
Processor Board . . . . . . . . . . . . . . . 101
Processor Board Jumpers ......... 102
System Board . . . . . . . . . . . . . . . . 103
14 PC Server HMM
System Board Jumpers .......... 105
U-Bolt Security (Option) ........... 106
Symptom-to-FRU Index . . . . . . . . . . . . . 107
No Beep Symptoms ............. 107
Beep Symptoms . . . . . . . . . . . . . . . 107
Error Codes . . . . . . . . . . . . . . . . . 111
Parts Listings . . . . . . . . . . . . . . . . . . 115
System . . . . . . . . . . . . . . . . . . . 117
Cables . . . . . . . . . . . . . . . . . . . 120
Keyboards (101/102 Key) .......... 121
Power Cords . . . . . . . . . . . . . . . . 122
Parts Listing (PC Server Advanced Systems
Management Adapter) . . . . . . . . . . . . . 123
Cables . . . . . . . . . . . . . . . . . . . 123
PC Server 325 - Type 8639 15

This manual suits for next models

1

Other IBM Server manuals

IBM Netfinity 7600 User manual

IBM

IBM Netfinity 7600 User manual

IBM 86473AX User manual

IBM

IBM 86473AX User manual

IBM Power 755 Owner's manual

IBM

IBM Power 755 Owner's manual

IBM pSeries 670 User manual

IBM

IBM pSeries 670 User manual

IBM Flex System p270 Compute Node Installation and maintenance instructions

IBM

IBM Flex System p270 Compute Node Installation and maintenance instructions

IBM 87401RU User manual

IBM

IBM 87401RU User manual

IBM System x3530 M4 User manual

IBM

IBM System x3530 M4 User manual

IBM 8203-E4A User manual

IBM

IBM 8203-E4A User manual

IBM X3850 X6 Installation and maintenance instructions

IBM

IBM X3850 X6 Installation and maintenance instructions

IBM Redbooks x3850 X5 User manual

IBM

IBM Redbooks x3850 X5 User manual

IBM System x3690 X5 User manual

IBM

IBM System x3690 X5 User manual

IBM 7327E1U User manual

IBM

IBM 7327E1U User manual

IBM RS/6000 44P Series 270 User manual

IBM

IBM RS/6000 44P Series 270 User manual

IBM 79463AU User manual

IBM

IBM 79463AU User manual

IBM 8676G1X User manual

IBM

IBM 8676G1X User manual

IBM E Server i Series User manual

IBM

IBM E Server i Series User manual

IBM 7944E2U User manual

IBM

IBM 7944E2U User manual

IBM System p5 505 User manual

IBM

IBM System p5 505 User manual

IBM 79784AU User manual

IBM

IBM 79784AU User manual

IBM eServer BladeCenter HS20Type 8832 Operating instructions

IBM

IBM eServer BladeCenter HS20Type 8832 Operating instructions

IBM eServer xSeries 235 Type 8671 User manual

IBM

IBM eServer xSeries 235 Type 8671 User manual

IBM pseries 655 User manual

IBM

IBM pseries 655 User manual

IBM xSeries 342 2RX User manual

IBM

IBM xSeries 342 2RX User manual

IBM 8687 - Eserver xSeries 440 Technical manual

IBM

IBM 8687 - Eserver xSeries 440 Technical manual

Popular Server manuals by other brands

Premio OSS212L-UN quick start guide

Premio

Premio OSS212L-UN quick start guide

SystemBase WiComm Installation and user guide

SystemBase

SystemBase WiComm Installation and user guide

QAT MS5 user manual

QAT

QAT MS5 user manual

Qsonix Q100 User guide addendum

Qsonix

Qsonix Q100 User guide addendum

Supermicro A+ Server 2123BT-HTR user manual

Supermicro

Supermicro A+ Server 2123BT-HTR user manual

Rasilient AI72 user manual

Rasilient

Rasilient AI72 user manual

Supermicro SuperServer SYS-621C-TN12R user manual

Supermicro

Supermicro SuperServer SYS-621C-TN12R user manual

Intel MFSYS25V2 specification

Intel

Intel MFSYS25V2 specification

MAXDATA PLATINUM 400IR M6 user manual

MAXDATA

MAXDATA PLATINUM 400IR M6 user manual

Sun Oracle Sun Ray 3i Client Getting started guide

Sun Oracle

Sun Oracle Sun Ray 3i Client Getting started guide

Fiery KM-C3130 User software installation guide

Fiery

Fiery KM-C3130 User software installation guide

Asus TS300-E5 user manual

Asus

Asus TS300-E5 user manual

Lantronix UDS200 user guide

Lantronix

Lantronix UDS200 user guide

Supermicro AS -1024US-TRT user manual

Supermicro

Supermicro AS -1024US-TRT user manual

Lantronix XPortPro user guide

Lantronix

Lantronix XPortPro user guide

Lenovo SE350 manual

Lenovo

Lenovo SE350 manual

TYAN Transport GX18 Quick installation guide