򔻐򗗠򙳰 Rack Installation Instructions
For 1500 VA, 2200 VA, and 3000 VA uninterruptible power
supplies and 2200 VA and 3000 VA extended battery modules
Use the instructions in this document to install the 1500 VA, 2200 VA, and 3000 VA uninterruptible power
supplies and 2200 VA and 3000 VA extended battery modules in a rack cabinet.
Review the documentation that comes with your rack cabinet for safety and cabling information.
When you install the uninterruptible power supply or extended battery module in a rack cabinet, observe
the following precautions:
vThe extended battery module and uninterruptible power supply internal battery and chassis are heavy.
Make sure that you have the minimum number of persons required to lift the components. See Table 1
on page 6 and Table 2 on page 7.
vMake sure that the room air temperature is below 35°C (95°F).
vDo not block any air vents; usually 15 cm (6 in.) of air space provides proper airflow.
vPlan the device installation starting from the bottom of the rack cabinet.
vInstall the heaviest device in the bottom of the rack cabinet.
vDo not extend more than one device out of the rack cabinet at the same time.
vConnect all power cords to properly wired and grounded electrical outlets.
vDo not overload the power outlet when you install multiple devices in the rack cabinet.
You will need a Phillips screwdriver to install the uninterruptible power supply or extended battery
module in a rack cabinet.
Note: The illustrations in this document might differ slightly from your hardware.
The following parts come with the rack mounting kit:
vOne right adjustable rail
vOne left adjustable rail
vFour adapter plates with adhesive (for round hole racks)
vSixteen M5 x 16 mm Phillips screws
Note: Removing the rack doors and side panels might make installation easier. See the rack cabinet
documentation for more information.
DANGER
Electrical voltage and current from power, telephone, and communication cables are hazardous.
To avoid a shock hazard:
vDo not connect or disconnect any cables or perform installation, maintenance, or reconfiguration
of this product during an electrical storm.
vConnect all power cords to a properly wired and grounded electrical outlet. Ensure outlet
supplies proper voltage and phase rotation according to the system rating plate.
vConnect any equipment that will be attached to this product to properly wired outlets.
vWhen possible, use one hand only to connect or disconnect signal cables.
vNever turn on any equipment when there is evidence of fire, water, or structural damage.
vDisconnect the attached power cords, telecommunications systems, networks, and modems before
you open the device covers, unless instructed otherwise in the installation and configuration
procedures.
vConnect and disconnect cables as described below when installing, moving, or opening covers on
this product or attached devices.
To Disconnect:
1. Turn everything OFF (unless instructed otherwise).
2. Remove power cords from the outlet.
3. Remove the signal cables from connectors.
4. Remove all cables from devices.
To Connect:
1. Turn everything OFF (unless instructed otherwise).
2. Attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach the power cords to outlets.
5. Turn device ON.
(D005)
CAUTION:
or
>18 kg (39.7 lb)
or 18-32 kg (39.7-70.5 lb)
The weight of this part or unit is between 18 and 32 kg (39.7 and 70.5 lb). It takes two persons to
safely lift this part or unit. (C009)
2
CAUTION:
or
>32 kg (70.5 lb)
or 32-55 kg (70.5-121.2 lb)
The weight of this part or unit is between 32 and 55 kg (70.5 and 121.2 lb). It takes three persons to
safely lift this part or unit. (C010)
Installing an uninterruptible power supply or extended battery module
in the rack cabinet
To install an uninterruptible power supply or extended battery module in the rack cabinet, complete the
following steps:
1. For racks with round holes only: Install one adapter plate on each of the ends of the right and left
rails:
a. Locate the four adapter plates that come in the rail kit.
b. Peel off the covering that protects the adhesive side of the adapter plate.
c. Align the adapter plate holes with the holes on one end of a rail.
d. Press firmly to adhere the adapter plate to the end of the rail.
e. Repeat step 1b to step 1d to attach the other adapter plates to the ends of the rails.
3
2. Loosen the rail adjustment screw and adjust the left and right rail length to the depth of the rack
cabinet.
3. Select a location in the bottom of the rack cabinet for the uninterruptible power supply or extended
battery module.
4. Secure each rail to the front of the rack with two M5 x 16 mm screws. Make sure that the rails are on
the inside of the rack-cabinet mounting flanges, and the letter on each rail faces inside the rack.
5. Secure each rail to the rear of the rack with four M5 x 16 mm screws.
6. Tighten the rail adjustment screws in the middle of each rail.
4
7. For uninterruptible power supply installation only: To reduce the weight of the uninterruptible
power supply, remove the internal battery module:
a. Loosen the thumbscrew on the metal battery cover 1, slide the cover to the right 2, and open
the cover 3.
b. Using the plastic tabs, pull the battery module partially out of the bay.
OK
OK
100%
6
min
1500
VA
208
V
/60hz
UPSON
OK
100%
6
min
1500
VA
208
V
/60hz
UPS ON
5
c. See the following table to determine how many people are required to lift the internal battery
module. Some battery modules might require two people to lift it.
Table 1. Internal battery module handling requirements
Battery description Weight Handling requirement
1500 VA internal battery module 8 kg (18 lb) One person
2200 VA internal battery module 16.3 kg (36 lb) One person
3000 VA internal battery module 21.3 kg (47 lb) Two persons
d. With two hands pull the battery module fully out of the bay and place it on a sturdy, flat surface.
Note: The 3000 VA battery module requires two persons to handle it.
e. Close the metal battery cover 1, then slide the cover slightly to the right and then to the left
2. Tighten the thumbscrew 3.
If you are installing another uninterruptible power supply, repeat step 7 on page 5.
6
8. The uninterruptible power supply and extended battery module are very heavy. See the following
table to determine the number of people that are required to install these devices.
Table 2. Uninterruptible power supply and extended battery module handling requirements
Machine
type-model or
part number Product description Weight Handling requirement
5395-1AX 1500 VA 2U rack
uninterruptible power supply
10.2 kg (22.6 lb) (chassis only) One person
5395-1KX 1500 VA 2U rack
uninterruptible power supply
11.3 kg (25 lb) (chassis only) One person
5395-2AX 2200 VA 2U rack
uninterruptible power supply
14.2 kg (31.3 lb) (chassis only) One person
5395-2KX 2200 VA 2U rack
uninterruptible power supply
14.4 kg (31.7 lb) (chassis only) One person
5395-3AX 3000 VA 3U rack
uninterruptible power supply
17.2 kg (37.9 lb) (chassis only) One person
5395-3JX 3000 VA 3U rack
uninterruptible power supply
17.9 kg (39.4 lb) (chassis only) Two persons
5395-3KX 3000 VA 3U rack
uninterruptible power supply
19.6 kg (43.2 lb) (chassis only) Two persons
46M4108 Extended battery module for
2200 VA 2U uninterruptible
power supply
41.2 kg (90.8 lb) Three persons
69Y1982 Extended battery module for
3000 VA 3U uninterruptible
power supply
52.2 kg (115.1 lb) Three persons
9. Align the rear hold down brackets on the sides of the uninterruptible power supply or extended
battery module with the inner rails. Carefully slide the uninterruptible power supply or extended
battery module into the rack cabinet.
10. Secure the front of the uninterruptible power supply or extended battery module to the rack cabinet
with four M5 x 16 mm screws.
7
11. For uninterruptible power supply installation only: To reinstall the battery module, complete the
following steps:
a. Loosen the thumbscrew on the metal battery cover 1, slide the cover to the right 2, and open
the cover 3.
8
b. With two hands (four hands for a 3000 VA battery module), carefully slide the battery module
into the uninterruptible power supply 1. For the number of people required to handle the
battery module, see the following table.
Table 3. Internal battery module handling requirements
Battery description Weight Handling requirement
1500 VA internal battery module 8 kg (18 lb) One person
2200 VA internal battery module 16.3 kg (36 lb) One person
3000 VA internal battery module 21.3 kg (47 lb) Two persons
OK
OK
100%
6
min
1500
VA
208
V
/60hz
UPSON
OK
OK
100%
6
min
1500
VA
208
V
/60hz
UPS ON
Internal battery
connector
c. Remove the internal battery connector from the holder on the metal battery cover; then, connect
the internal battery connector 2.
Note: A small amount of arcing might occur when you connect the batteries. This is normal and
does not damage the unit or present any safety concern.
9
d. Close the metal battery cover 1, then slide the cover slightly to the right and then to the left
2. Tighten the thumbscrew 3.
12. Locate the bezel that comes with the uninterruptible power supply or extended battery module.
Press the two side latches toward each other, align the bezel with the uninterruptible power supply
or extended battery module, and snap it into place.
OK
OK
100%
6
min
1500
VA
208
V
/60hz
UPSON
10
13. Remove the clear protective film that covers the liquid crystal display (LCD) on the front of the
uninterruptible power supply.
For more information about installing and operating the uninterruptible power supply and extended
battery module, see the Installation and Maintenance Guide that comes with the uninterruptible power
supply.
Store this information with your uninterruptible power supply documentation for future use.
11
Second Edition (May 2011)
IBM is a trademark of International Business Machines Corporation in the United States, other countries, or both.
Printed in USA
© Copyright IBM Corporation 2010, 2011.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
(1P) P/N: 60Y1453

Other manuals for 1500VA

2

This manual suits for next models

2

Other IBM UPS manuals

IBM SurePOS 500 User manual

IBM

IBM SurePOS 500 User manual

IBM 1000VA Product manual

IBM

IBM 1000VA Product manual

IBM UPS3000 LV Product manual

IBM

IBM UPS3000 LV Product manual

IBM 1000VA User manual

IBM

IBM 1000VA User manual

IBM 6000 VA LCD 4U User manual

IBM

IBM 6000 VA LCD 4U User manual

IBM 3000XLV User manual

IBM

IBM 3000XLV User manual

IBM 2145UPS-1U Manual

IBM

IBM 2145UPS-1U Manual

IBM UPS1000THV User manual

IBM

IBM UPS1000THV User manual

IBM 6000 VA LCD 4U Product manual

IBM

IBM 6000 VA LCD 4U Product manual

IBM 3000XLV User manual

IBM

IBM 3000XLV User manual

IBM 11000 VA LCD 5U User manual

IBM

IBM 11000 VA LCD 5U User manual

IBM 9910-E36 User manual

IBM

IBM 9910-E36 User manual

IBM 1000VA User manual

IBM

IBM 1000VA User manual

IBM 2200VA LCD 2U User manual

IBM

IBM 2200VA LCD 2U User manual

IBM 5000XHV User manual

IBM

IBM 5000XHV User manual

IBM 5594-1AX User manual

IBM

IBM 5594-1AX User manual

IBM UPS 7500XHV User manual

IBM

IBM UPS 7500XHV User manual

IBM System Storage TS3100 Manual

IBM

IBM System Storage TS3100 Manual

IBM 700 RM UPS User manual

IBM

IBM 700 RM UPS User manual

IBM 11000 VA LCD 5U Product manual

IBM

IBM 11000 VA LCD 5U Product manual

IBM 1500VA Use and care manual

IBM

IBM 1500VA Use and care manual

IBM 5595-1AX User manual

IBM

IBM 5595-1AX User manual

Popular UPS manuals by other brands

socomec ITYS Installation and operating manual

socomec

socomec ITYS Installation and operating manual

CyberPower PR1000LCDRT2U user manual

CyberPower

CyberPower PR1000LCDRT2U user manual

Riello MST 30 Installation and use manual

Riello

Riello MST 30 Installation and use manual

Riello Dialog Plus user manual

Riello

Riello Dialog Plus user manual

CyberPower CST135UC2 Setup guide

CyberPower

CyberPower CST135UC2 Setup guide

Eaton Eaton 5PX manual

Eaton

Eaton Eaton 5PX manual

Schrack Technik AVARA USMPXPW130 user manual

Schrack Technik

Schrack Technik AVARA USMPXPW130 user manual

Manhattan 168229 Features & specifications

Manhattan

Manhattan 168229 Features & specifications

Trust 17238 Quick installation guide

Trust

Trust 17238 Quick installation guide

Tecnoware EXA 2.6 user manual

Tecnoware

Tecnoware EXA 2.6 user manual

ARTronic T6K manual

ARTronic

ARTronic T6K manual

LEGRAND MIDDLE ATLANTIC NEXSYS UPX-EXPANRUN-10-15 user manual

LEGRAND

LEGRAND MIDDLE ATLANTIC NEXSYS UPX-EXPANRUN-10-15 user manual

Vertiv NetSure 48 Series Installation and user manual

Vertiv

Vertiv NetSure 48 Series Installation and user manual

Huawei UPS5000-E Series quick guide

Huawei

Huawei UPS5000-E Series quick guide

Alpha Technologies Sentra 1000 user manual

Alpha Technologies

Alpha Technologies Sentra 1000 user manual

CyberPower EC550G user manual

CyberPower

CyberPower EC550G user manual

Huawei SmartLi 2.0 user manual

Huawei

Huawei SmartLi 2.0 user manual

Eaton 9PX 1000i Installation and user manual

Eaton

Eaton 9PX 1000i Installation and user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.