OVERHEAD ARM INSTALLATION 01/20/16 pjm
OVERHEAD ARM INSTALLATION
Page 3 of 4
OVERHEAD ARM INSTALLATION
MOUNT WALL PLATE TO WALL
MAXIMUM LOAD CAPACITY:
28 LBS (12.7 KG)
CENTER MOUNTED ON ONE STUD (16” or 24” spaced studs)
Locate a stud in the wall where wall plate will be mounted, determine desired height,
and mark the top (center) hole.
For wood studs:
• Drill 11/64” pilot hole and insert #14 wood screw (provided), tighten slightly.
• Using a level, mark the remaining 3 holes in the center of the plate and one hole in
each edge of the plate. Remove the plate and pilot each hole.
• Following the Snaptoggle installation instructions on next page, install Snaptoggles
inthetwoedgeholes.Replaceplateusing4#14screwsand2¼-20x2-1/4”at
Phillips head machine screws. Check level and tighten all 6 screws.
For steel studs:
• Drill 11/64” pilot hole, then follow Snaptoggle installation instructions on next page.
• Attachplateusing¼-20x2-1/4”atPhillipsheadmachinescrew,tightenslightly.
• Using a level, mark the remaining 3 holes in the center of the plate and one hole in
each edge of the plate.
• Remove the plate, pilot, and install Snaptoggles in all 5 holes.
• Replaceplateusing6¼-20x2-1/4”atPhillipsheadmachinescrews.Checklevel
and tighten all 6 screws.
SPANNING TWO STUDS (16” spaced studs only)
Locate two studs in the wall where wall plate will be mounted, determine desired
height, using a level, mark the top hole in each edge of the plate.
For wood studs:
• Drill 11/64” pilot holes and insert 2 #14 wood screws (provided), tighten slightly.
Using a level; pilot the remaining 4 holes in the edges of the plate and insert #14
screws. Check level and tighten all 6 screws.
For steel studs:
• Drill 11/64” pilot holes then follow Snaptoggle installation instructions on next page,
attachplateusing2¼-20x2-1/4”atPhillipsheadmachinescrews,tightenslightly.
Using a level; mark the remaining 4 holes in the edges of the plate.
• Remove the plate, pilot, and install Snaptoggles in all 4 holes.
• Replaceplateusing6¼-20x2-1/4”atPhillipsheadmachinescrews.Checklevel
and tighten all 6 screws.
UL182-OHAP