manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICW
  6. •
  7. Rack & Stand
  8. •
  9. ICW MD ARM User manual

ICW MD ARM User manual

Other ICW Rack & Stand manuals

ICW Ultra 110 Series User manual

ICW

ICW Ultra 110 Series User manual

ICW ELITE DOUBLE ARM User manual

ICW

ICW ELITE DOUBLE ARM User manual

ICW TITAN ELITE T2EQ-C8X5 User manual

ICW

ICW TITAN ELITE T2EQ-C8X5 User manual

ICW Elite User manual

ICW

ICW Elite User manual

ICW ELITE 5220 User manual

ICW

ICW ELITE 5220 User manual

ICW PRO SLIDE User manual

ICW

ICW PRO SLIDE User manual

ICW ELITE 5220 User manual

ICW

ICW ELITE 5220 User manual

ICW TITAN ELITE T2E12P-WT2-KUB User manual

ICW

ICW TITAN ELITE T2E12P-WT2-KUB User manual

ICW EV65 User manual

ICW

ICW EV65 User manual

ICW TITAN 2020 User manual

ICW

ICW TITAN 2020 User manual

ICW Elite User manual

ICW

ICW Elite User manual

ICW ULTRA User manual

ICW

ICW ULTRA User manual

ICW Elite ELP5220 User manual

ICW

ICW Elite ELP5220 User manual

ICW ULTRA 180 User manual

ICW

ICW ULTRA 180 User manual

ICW UL182 OHAP User manual

ICW

ICW UL182 OHAP User manual

ICW MD User manual

ICW

ICW MD User manual

ICW EV65 User manual

ICW

ICW EV65 User manual

ICW T2P2020 User manual

ICW

ICW T2P2020 User manual

ICW SINGLE ARM ELITE User manual

ICW

ICW SINGLE ARM ELITE User manual

ICW LTU-W3-A2 User manual

ICW

ICW LTU-W3-A2 User manual

ICW W2 User manual

ICW

ICW W2 User manual

ICW T2 User manual

ICW

ICW T2 User manual

ICW Titan Elite User manual

ICW

ICW Titan Elite User manual

ICW Elite User manual

ICW

ICW Elite User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MD ARM INSTALLATION INSTRUCTIONS
MD ARM INSTALLATION - 12/3/19
Page 1 of 2
MAXIMUM LOAD CAPACITY:
35 LBS (15.9 KG)
If Mounting Directly To Wall
ATTACH WALL PLATE TO WALL
Locate a stud in the wall
where the arm will be
mounted. Mark the top hole
and drill a 11/64 pilot hole.
Insert a provided #14 screw
and tighten slightly. Using
a level, mark the two lower
holes and drill pilot holes.
Insert #14 screws and, with
the mount level, tighten all
screws securely.
If Mounting To Wall Track
Lift the wall mount up to the
bottom of the TMD track,
or lower over the top of
the track if it’s easier. Slide
the clamp plates into the
groove in the TMD track.
Clamp
screws
ATTACH WALL PLATE TO TRACK
Once the wall plate is
at the desired height,
lock into place by
turning the 3 clamping
screws clockwise with
provided 5/32 hex key.
Track
clamp
plates
Cable Management
REMOVE COVERS FROM ARM
Using a Phillips head screwdriver, remove 3 screws
and slide front cover forward. Remove 4 screws from
the upper cover, and lift it o󰀨.
Remove the lower cover by lowering the arm into the
down position, removing the screws and sliding the
cover forward o󰀨 of the arm.
WARNING - PINCH POINT:
Keep ngers away from the inner arm area where
the gas spring is located.
Front
cover Lower
cover
Upper
cover
RUN WIRES & REATTACH ARM COVERS
Run monitor wires through top channel.
Run keyboard
wire through
lower channel
Snap black plastic bushing around exiting wires and
push bushing rmly into end cover port.
Replace upper and lower covers on the arm. DO NOT
use a power tool to tighten screws.
Slip wires from lower channel through
end cover port, then reattach cover to
the front of the arm. DO NOT use a
power tool to tighten screws.
MD ARM INSTALLATION INSTRUCTIONS
MD ARM INSTALLATION - 12/3/19
Page 2 of 2
ADJUST ARM RESISTANCE
Using the 3/16” T-handle hex
wrench provided, turn the
screw in the MD arm clockwise
to lighten the arm’s load
resistance, or counter-clockwise
to increase the load resistance.
MONITOR TILT, ROTATION & ADJUST MONITOR DEPTH
MONITOR TILT
& ROTATE
Gently hold sides
of monitor. Tilt and
rotate to desired
position with ball
VESA.
ADJUST
MONITOR
DEPTH
Loosen the
adjustment
knob, move
the Paralink
forward or
back, then
re-tighten
the knob.
Adjustment
Knob
ADJUST BALL VESA TENSION & HEIGHT
Pivot tension
adjustment screws
Use the slider knob to
loosen the slider to adjust
the height of the monitor
on the Paralink.
Adjust the pivot tension
of the ball by gently and
evenly tightening or
loosening the four
screws on the back
of the ball VESA.
Slider knob
If Using Ultra Keyboard Tray
ATTACH FLIP UP KEYBOARD TRAY
Remove screws from the drop
extension using 5/32” hex key.
Align holes in keyboard tray
with screw holes in drop
extension.
Attach keyboard tray using
the provided screws.
If Using Paralink Keyboard Tray
ATTACH PARALINK KEYBOARD TRAY
Attach the Paralink
keyboard tray to
the arm by using
the 3/8-16 screw
and lock washer
provided.
Attach the THBV handle to the
back of the VESA plate using
provided screws.
ATTACH THBV HANDLE
ATTACH VESA
Attach VESA to monitor using four
M4 screws in the hardware bag.
Mount the VESA assembly
by screwing the knob through
the rail into the VESA.
NOTICE: ICWUSA.COM, Inc. provides the appropriate hardware fasteners to
match the majority if not all standard monitors and devices. It is the responsibility
of the installer / integrator to ensure that the screws and fasteners have the
adequate thread engagement. The rule of thumb is that the thread depth is
greater than the diameter of the hole or 4 full turns of 360 degrees of thread
engagement. It is also the responsibility of the installer / integrator to ensure that
they do not damage the monitor or device by using a screw or fastener that is too
long for hole and therefore damaging the unit by inserting too far.
When cleaning your ICW mounting unit please follow the points below. Proper cleaning
of the mounting device will help assure proper function and extend the life of the unit.
1. Any general cleaner is acceptable except degreasers are not recommended near the
bearing entrances.
2. Spray cleaner or water on a soft cloth or paper towel and then wipe down
the mounts.
3. Do not spray directly at the bearing seams (located at all swivel points) as this could reduce
the life of the bearings.
CLEANING OF THE ICW MOUNTING DEVICE