ID Lock 101 series Quick start guide

Monteringsveiviser
101-serien
V5.0 NO · 02.03.2015
Operational Manual for
ID Lock 101 with
Z-Wave Module 01A

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
Operational Manual - Z-Wave module board 01A -
For ID Lock -101 series Doorlocks
v1.2 English released - 01.09.2016
Getting started…
IMPORTANT: Batteries must be removed prior to removing or
inserting the interface module.
Inclusion – (Puts your device in inclusion mode)
• Push and hold button until all LEDs on keypad
activates. (with ID Lock in an unlocked state)
• Release button and press “8” on keypad.
Inclusion mode starts immediately. LED indicator below logo
signals this by flashing blue.
Exclusion – (Puts your device in exclusion mode)
• Push and hold button until all LEDs on keypad
activates. (with ID Lock in an unlocked state)
• Release button and press “8” on keypad.
Exclusion mode starts immediately. LED indicator below
logo signals this by flashing blue.
Device reset – (This will reset RF interface module to factory default
settings)
Warning: Please do only proceed with the following reset procedure,
if primary network controller is missing or otherwise inoperable.
• Push and hold button until all LEDs on keypad
activates. (with ID Lock in an unlocked state)
• Release button and press “0” on keypad.
Exclusion mode starts immediately. LED indicator below
logo signals this by flashing blue.

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
SUPPORTED COMMAND CLASSES
Non Secure mode
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
5E
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
72
COMMAND_CLASS_SECURITY_V1
98
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
5A
COMMAND_CLASS_BATTERY_V1
80
COMMAND_CLASS_POWERLEVEL_V1
73
COMMAND_CLASS_CONFIGURATION_V1
70
Secure Mode
COMMAND_CLASS_VERSION_V2
86
COMMAND_CLASS_DOOR_LOCK_V2
62
COMMAND_CLASS_USER_CODE_V1
63
COMMAND_CLASS_ASSOCIATION_V2
85
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
59
COMMAND_CLASS_NOTIFICATION_V4
71
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
7A
CONFIGURATON PARAMETER
These configuration parameter number and values are specific for application.
COMMAND_CLASS_CONFIGURATION
Name
Parameter
Number
Size
Description
Configuration
Set parameter
1
1
Door Lock Mode
2
2
RFID Registration Mode
3
1
Door Hinge Position Mode
4 ~ 9
Reserved ( For later use )
Door Lock Mode(s):
Autolock Mode, Manuallock mode, Activate Away Mode, Deactivate Away Mode
Default Value : 1 ( Disable Away / Auto Lock Mode )
Name
Parameter
Number
Size
Value
Description
Door Lock
Mode
1
1
0
Disable Away
Manual Lock
1
1
1
Disable Away
Auto Lock
1
1
2
Enable Away
Manual Lock
1
1
3
Enable Away
Auto Lock

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
RFID Registration Configuration:
ID Lock can use up to 50 RFID cards. In order to use a RFID, RFID has to be registered by Z-
Wave configuration command class.
Configuration Set in case of starting to register from backend side ( Ex. App)
Name
Parameter
Number
Size
Value1
Value2
Description
RFID Register
2
2
0x01
0x00
Begin RFID Registering mode on the
door lock
2
2
0x07
0x00
RFID Database clear
2
2
0x08
0x00
RFID Registering mode stop
l Configuration Report regarding Configuration Set
According to the process of registration RFID, these configuration reports are transmitted to
the gateway.
Name
Parameter
Number
Size
Value1
Value2
Description
RFID Register
Mode
2
2
0x02
0x00
Fail
Registration new RFID was fail
2
2
0x03
RFID
Index
Number
Success
Registration new RFID was
Successful
RFID Index : 10 ~ 59
2
2
0x04
0x00
Finished
Registration mode finished and
end
2
2
0x05
0x00
Not In Progress
RFID Registration mode not in
progress
2
2
0x06
0x00
In Progress
RFID Registration mode in progress

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
RETRIVE RFID INFORMATION:
Configuration Get (for retrieving RFID information)
Name
Parameter
Number
Description
Get RFID
Infomation
10 ~ 59
RFID Information registered
Parameter Number means RFID index.
10 = RFID index 1
....
59 = RFID index 50
Configuration Report for retriving the RFID information
For example : RFID index is 1 and information is 0xFDBEC2DE
Name
Parameter
Number
Size
Para1
Para2
Para3
Para4
Get RFID
Infomation
10
4
0xFD
0xBE
0xC2
0xD2
NOTIFICATION PARAMETERS
These Notification parameters ( types and levels) are specific for application.
ID Lock supports the Notification Class(V4) to report events of ID Lock.
The type and event are specific for IDLock and defines are as below.
COMMAND_CLASS_NOTIFICATION(V4):
Notification Type
Event
Event
Parameter
Description
Access Control
(0x06)
Manual Lock Operation
(0x01)
Manual Unlock Operation (0x02)
RF Unlock Operation
(0x04)
RFID Index Info.
Unlock by RFID
Keypad UnLock Operation
User ID of User
User ID = 1 (Master

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
(0x06)
Code Report
PIN)
User ID =2 ( Service
PIN)
User ID =0 ( Remote
Unlock)
Unlock By RF with invalid user
code (0x14)
Unknown
Credential
Infomation
Unknown PIN Code
Or
Unknown RFID
Home Security(0x07)
Tampering,
Product covering Removed
(0x03)
Door Forced Open
Emergency (0x0A)
Contact Fire Service (0x2)
Fire Sensor
Use Case of Manual Lock Notification
Example : Lock the door by Maual or RFID / Keypad
Notification
Type
Notification
Event
Para
Length
0x06
0x01
0
Use Case of Manual Unlock Notification
Example : Unlock the door by thumbturn switch or open/close button
Notification
Type
Notification
Event
Para
Length
0x06
0x02
0
Use case of RF Unlock Operation
Example : Unlock the door by RFID Card ( Ex. RFID Index is 10 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x04
0x01
0x0A
Use case of Keypad Unlock Operation
Example : Unlock the door by Keypad using PIN Code
The vaule of para1 means User ID of Master PIN ( User ID = 1 )

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x01
The vaule of para1 means User ID of Service PIN ( User ID = 2 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x02
If the door is unlocked by remote side from mobile Application, in order to know the status,
the value of para1 means remote User ID ( application specific value = 0 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x00
Use case of Unlock by RF with invalid user code
Example : Invalid PIN code Notification Report
PIN Type is 1 value and Invalid PIN code is 785469
Notification
Type
Notification
Event
Para
Length
Para1
Para2
Para3
Para4
0x06
0x14
4
0x01
0x78
0x54
0x69
Example : Invalid PIN code Notification Report
RFID Type is 2 value and Invalid RFID is 0x89AE939C
Notification
Type
Notification
Event
Para
Length
Para1
Para2
Para3
Para4
Para4
0x06
0x14
5
0x02
0x89
0xAE
0x93
0x9C
Use case of Tampering ( Door Forced Open)
Example : When the door is opened forcely (Alarm )
Notification
Type
Notification
Event
Para
Length

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
0x07
0x03
0x00
Use case of Emergency ( Fire Sensor )
Example : The fire is detected by fire sensor of door lock
Notification
Type
Notification
Event
Para
Length
0x0A
0x02
0x00
Manufacture Parameter
ID Lock supports the Manufacture Specific Command Class with following parameters.
COMMAND_CLASS_MANUFACTURE_SPECIFIC_V2
Name
Value
Description
Manufacture ID
0x0230
Product Type ID
0x03
PRODUCT_TYPE_ID_ZWAVE_PLUS
Product ID
0x01
PRODUCT_ID_DoorLockKeyPad
ID Lock supports the Door Lock Command Class Version 2 by the following parameters.
COMMAND_CLASS_VERSION_V2
Name
Value
Z-Wave Protocol Library Type
0x03
Z-Wave Protocol Version
0x04
Z-Wave Protocol Sub version
0x05
Firmware 0 Version
0x01
Firmware 0 Sub Version
0x00
Hardware Vesion
0x01

!
ID!Lock!AS!–!Stasjonsveien!46,!4460!Moi,!Norway!
Association & Association Group Parameter
ID Lock supports 1 association group with 5 devices.
Notification Reports are sent out unsolicated to device included in the association group.
○Grouping identifier : 1
○Name : Lifeline
User Code Parameter
ID Lock have 2 pin codes(Master PIN and Service PIN ) that are 4 -10 digit in lengh.
○Master PIN : User Identifier 1
○Service PIN: User Identifier 2
Table of contents
Other ID Lock Door Lock manuals
Popular Door Lock manuals by other brands

Allegion
Allegion FALCON 24-C installation instructions

Zebratti
Zebratti LCS Series Installation instruction

CODELOCKS
CODELOCKS GLASS DOOR LOCK installation instructions

Kaba
Kaba PowerLever 1550 installation guide

SAFE TRON
SAFE TRON SAFETRON 5000 Series manual

Assa Abloy
Assa Abloy Pemko 4131RL installation instructions