8
9 Technical data
Setting range
- SBU323 [l/min] ....................................................................................................... 0.3...25
- SBU324 [l/min] ....................................................................................................... 0.3...50
- SBU325 [l/min] ....................................................................................................... 0.3...75
Operating voltage [V]....................................................................... 24 DC (-15 % / +10 %)
Current rating [mA] ......................................................................................................... 100
Protected against short circuits, reverse polarity and overload
Voltage drop [V].............................................................................................................< 2.5
Current consumption [mA]..............................................................................................< 15
Hysteresis
- SBU323 [l/min] ...................................................................................................... 0.1...1.0
- SBU324 [l/min] ...................................................................................................... 0.1...1.5
- SBU325 [l/min] ...................................................................................................... 0.2...2.0
Repeatability [% of value of measuring range]....................................................................1
Accuracy [% of value of measuring range].......................................................................± 5
Response time [s]........................................................................................................< 0.01
Materials (wetted parts).......................... stainless steel 316 / 1.4401; aluminium anodised;
PEEK; O-ring: FPM (Viton)
Housing materials....................................................................... aluminium anodised; steel
Protection ............................................................................................................... IP 67 III
Switching cycles min. ........................................................................................... 10 million
Medium temperature [°C] ........................................................................................... 0...60
Operating temperature [°C] ........................................................................................ 0...60
Pressure resistance [bar]................................................................................................ 200
Temperature changes affect the specified standard settings for coolants.
For oils, the settings are influenced by temperature and viscosity.
More information at www.ifm.com