Intratone EEN-PIVIV3 Guide

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 1 / 12
INSTALLATION AND CONNECTION OF THE
BUILT-IN Visio call panel
General points
The built-in Visio call panel (ref.: EEN-PIVIV3) a multifunctional call panel which transmits
an image of the visitor to the resident's telephone.
This call panel is available in a "Stainless-steel" coloured finish and is flush-mounted. It
is configured using the following website: www.intratone.com in the "management
website" tab
It must be connected to the following "real-time" central units:
2 to 4 doors (ref.: EEN-CEN12)
1 door (ref.: EEN- CIC12)
Ideal for installation near an entrance gate; four opening methods are possible:
By using an authorised badge
By typing in a specific code
By calling a resident using the call panel, who then opens the cabinet using a key on
his/her telephone
Using a "mobilekey".
Product description:
The Visio telephone intercom with scrolling name-display consists of:
A 12-key keypad and backlit LCD screen
Two scrolling keys and one call button
A proximity reader.
A miniature camera for use in video calls
Built-in speech synthesiser: "Call in progress"; "Door open", etc.
+
Screws
X 6
+
LCD display
Proximity reader
Keys on Keypad
Scrolling keys
Call buttons
Built-in wall
box

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 2 / 12
Contents
GENERAL POINTS-----------------------------------------1
CONTENTS---------------------------------------------------2
DIMENSIONS AND ASSEMBLY------------------------3
A) DIMENSIONS OF CALL PANEL ---------------------------------------------------------3
B) BUILT-IN BOX DIMENSIONS------------------------------------------------------------4
CABLING------------------------------------------------------5
A) GENERAL POINTS ---------------------------------------------------------------------- 5
B) FOR USE IN AUDIOCALLS ONLY ---------------------------------------------------- 5
C) FOR USE IN VIDEO CALLS------------------------------------------------------------5
D) SCENARIO OF CONNECTING AN ENTRANCE GATE WITH THE 2TYPES OF
CENTRAL UNITS--------------------------------------------------------------------------------6
E) SCENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING -------------6
EQUIPMENT CONFIGURATION------------------------7
A) GENERAL POINTS ----------------------------------------------------------------------7
B) CONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT,EEN-CEN12----------7
C) CONFIGURATION WITH AN INTRACODE EEN-CIC12 CENTRAL UNIT ------------8
POST-FITTING CHECK -----------------------------------9
D) ON THE PANEL ------------------------------------------------------------------------- 9
E) DOOR CONNECTION-------------------------------------------------------------------- 9
F) CALLS------------------------------------------------------------------------------------9
G) IN THE CASE OF A FITTING WITH A 3G UNIT -----------------------------------------9
H) IN THE CASE OF A FITTING WITH AN EEN-CIC12 CENTRAL UNIT ----------------9
DIAGNOSIS IN THE EVENT OF A FAULT---------10
CERTIFICATE OF CONFORMITY--------------------11
A) STANDARDS:-------------------------------------------------------------------------- 11
B) CERTIFICATE:------------------------------------------------------------------------- 12

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 3 / 12
Dimensions and assembly
A) Dimensions of call panel

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 4 / 12
B) Built-in box dimensions

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 5 / 12
CABLING
See EEN-CIC12 guide : V233 - 5002 - XX
See EEN-CEN12 guide: V233-5001-XX
A) General points
POWER SUPPLY : The central unit supplies power to the call panel via the + / - terminals.
CABLING : Twisted pairs –Diameter: 0.8 –Max. distance 100 metres.
Important note:
- The video function will only work if the call panel is installed with a 3G unit.
- If the call panel is installed with a PSTN line, only audio will work.
AUDIO
++ or
VIDEO
++ or
B) For use in AUDIO calls only
Connect the following terminals up to the central unit:
Terminal
Detail
NB pair
+ / -
Power supply
1
D-+ / D-
Data
1
A+ / A-
Audio
1
C) For use in VIDEO calls
Also connect the following terminals up to the V+ / V- (VIDEO 1) terminals on the
3G unit:
Terminal
Detail
NB pair
V+ / V-
Video
1
EEN-CIC12
EEN-
M3G
EEN-M3G
EEN-M3G
EEN-PVICBV3
EEN-PVICBV3
THE CENTRAL UNITS
THE CENTRAL UNITS
+
-
D+
D-
+ - D+ D-
V+
V-
A+
A-
Power supply: 12 / 24 V –2 to 4 A
Not supplied
+ - D+ D- A+A-
V+
V-
EEN-
M3G
EEN-CEN12
+
-
D+
D-
A+
A-
Twisted pair MANDATORY
for video
Twisted pair recommended

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 6 / 12
D) Scenario of connecting an entrance gate with the 2 types of central units
Connections in red refer to video (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
E) Scenario of connecting an entrance gate plus a building
It is mandatory to use an EEN-CEN12 central unit with, in this example, an extension board.
Scenario:
"Audio and Video" calls from the entrance gate
Only "Audio" calls can be made from the building entrance.
/ 4
/2
/ 6
/ 6
/ 6
Add an extension board - doors 3
and 4
/ 6
/ 6
/ 2
/ 2
/ 2
In this example, door 4 remains available
[41 49 and CRT]
Connections in red refer to Visio (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
Extension board
Entrance
gate
Building

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 7 / 12
Equipment configuration
A) General points
INTRATONE call panels are mainly configured on the www.intratone.com website in
the "management website" tab.
Nevertheless, some settings can be changed on-site:
- Configuration of the push button.
- Configuration of the door-opening time.
- Panel sound volume
B) Configuration with a Residential central unit, EEN-CEN12
(See central unit guide EEN-CEN12 V233-5001-XX)
With regard to the push button and of the door-opening time, see the "Door settings"
menu on the central unit.
With regard to the volume level, you have 2 options in the "Panel volume" menu:
- "Direct selection of volume":
Enter a value between 1 and 4 corresponding to the sound level.
- "Settings on the Panels":
This menu starts a 15-minute timer. During this time, you can move between the call
panel or panels connected to this central unit in order to adjust the sound level.
Step 1:
Type in the keypad
code: "12345678"
Step 2:
The call panel automatically
starts
« sound level adjustment"
which continues repeatedly.
step 3 :
Validate
the chosen level
by pressing the
call button
on the call panel
This procedure is valid for 15 minutes per the timer. To exit from this procedure, wait until the
timer finishes or exit from the "Settings on the panels" menu.
Sound level
adjustment

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 8 / 12
C) Configuration with an Intracode EEN-CIC12 central unit
- How do I enter settings mode?
oCheck that the welcome message is scrolling on the LCD
oPress the key until the "Enter password" menu appears.
oType the serial number of the EEN-CIC12 central unit (7xxxxxx3).
oValidate with the key. « You are in menu settings mode"
- To exit settings mode:
oPress the arrow key several times until you return to the scrolling message.
Menu options in settings mode:
Setting
the clock
Date: 28/01/13
Day: Monday
Numeric keys for date entry
Keyto select day
|
|
|
Time: 09:15
Type: winter
Numeric keys for time entry
Key to select summer/winter season
|
|
|
Accept remote
time: YES
Keyto select YES or NO
Door
settings
Door settings
PB:NO Opening time:
05s
Keyto select: NO or NC
Numeric keys for door-opening time entry
|
|
|
or
Key to Exit
Key to Validate
Volume of
call panels
Direct selection
of the volume
Enables direct input via the keypad of the
volume of the call panel connected
INTERNET Update
Request
Request an Update?
Key to Validate
Check fitting
Test number:
Enables direct input of the telephone number
via the keypad to call for test purposes.
|
|
Start test procedure
Warning: the "door settings" menu will appear only if switches 4 / 5 / 6 on the EEN-
CIC12 central unit are set to OFF.
Entering numbers
Exit from menus or
Return to scrolling menu
Go into menus or Make a
selection
Validation
"Save changes"

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 9 / 12
Post-fitting check
Before leaving the fitting, the following points should be checked:
D) On the Panel
- Display shows the welcome message
- Check that the keypad keys (0, 1, 2 9, * and #) work.
Procedure:
oPress #; the display shows "Call number"
oThe numeric keys must be displayed correctly
oFinish using the * key; the display should return to the welcome message.
- Check that the keypad keys are backlit.
E) Door connection
- Check door opening with the push button
- Check door opening using a badge
(See Test Procedure in the central unit guide)
F) Calls
- Check the quality of a call by a visitor to a resident:
oAudio Call
oVideo Call
- Check that, during the call, the resident can open the door by pressing the * key on
his/her telephone
(See Test Procedure in the central unit guide)
G) In the case of a fitting with a 3G unit
If you use a 3G unit with your call panel, you can see the signal reception level for the unit
by pressing the 2 scrolling arrow keys on the display.
Depending on the situation, you will see:
"3G NET Lev 17 3" or "GSM NET Lev 17 3»
- NET : shows that the network has been found by the unit (3G or GSM)
- Lev : shows the level out of 30 (here,17 / 30) and the connection on a scale of 5
(here 3/ 5)
Press one of the arrow keys to exit from this menu.
H) In the case of a fitting with an EEN-CIC12 central unit
Remember to make a note of the serial number (7XXXXXX3) of the central unit.
You will need this to go back into the installation and configure these settings on the
keypad outside.

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 10 / 12
diagnosis in the event of a fault
What is the fault?
What is causing the
fault?
How to fix the fault!
Message on the display:
« Communication error»
Incorrect cabling on the
D+ and/or D- terminals
- Check cabling between the 3G
unit, the call panel and the
central unit: D+ and or D-.
- The display should show the
welcome message.
Keys and display
not backlit
- Incorrect cabling on the
+ and/or - terminals
- Equipment fault
- Check cabling on the + and/or -
terminals
- Contact our technical support
department
Keys backlit but not
display (or the reverse)
Contact our technical support department
The LCD screen does not
come on
Incorrect cabling on the +
and/or - terminals
Check cabling between the
central unit and the call panel: + /
-
When swiping a badge, the
green LED on the reader
lights up but the door does
not open.
- Relay on the central unit
not working.
- Cable to the door
- Check if relay sticks
- Check cabling between the
central unit and the door
If the call panel says "Call
in progress" but the
resident cannot hear the
visitor
Incorrect cabling on the
A+ and/or A- terminals
Check A+ / A- cabling
The call panel says
"Unable to call" with no dial
tone
Telephone network not
available
Check cabling to the GSM unit
and LED levels
The resident cannot see
the visitor on his/her
telephone
- Incorrect V+ / V- cabling
- Call panel not a Visio
panel
- The unit is not a 3G unit
- The telephone does not
support video
- Check V+ / V- cabling
- Install an EEN-PICVIV1 call panel
instead of an EEN-PIC
- Install a 3G unit instead of a GSM
one.
Contact our technical support department (+33 (0)251 655 529)

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 11 / 12
CERTIFICATE OF CONFORMITY
A) Standards:
EC standards:
The central unit complies with the R&TTE Directive 1999/5/EC: electrical safety
standard EN 60950(2001) applied, EMC standard EN 301 489-3 (2002) applied, radio
standard EN 300 330-2 (2001) applied
The central unit complies with the telephone network standards TS-103 021 and TR-
103 000.
Cabling:
The cables connected to the central unit must not be placed in the vicinity of other
sources of electrical power (e.g. mains power supply).
Operating warranty:
The call panel is guaranteed for a temperature range of between -20°C and +70°C and
for relative humidity not exceeding 70%.
End of life product recycling:
The panel and its accessories must not be disposed of with unsorted municipal
waste but must be follow the WEEE (Waste Electrical and Electronic Equipment
Directive) collection and recycling channel.

EN-V233 –5005 –AA Installation and use of built-in Visio call panel EEN-PIVIV3
Page 12 / 12
B) Certificate:
Table of contents
Other Intratone Intercom System manuals

Intratone
Intratone SPECIAL RENOVATION Guide

Intratone
Intratone Intracall 14-0144 Quick start guide

Intratone
Intratone 32-0003 User manual

Intratone
Intratone 02-0154-EN Guide

Intratone
Intratone 02-0126 User manual

Intratone
Intratone 02-0182 User manual

Intratone
Intratone Visio 02-0166-EN Guide

Intratone
Intratone SC-01 User manual

Intratone
Intratone LABEL MODULE User manual

Intratone
Intratone 02-0182 User manual