IRT DVA-3004 User manual

3004-dva.ib.doc Page 1 of 9 16/07/2002
IRT Eurocard Type
DVA-3004
Serial Digital Distribution Amplifier
Designed and manufactured in Australia
IRT can be found on the Internet at:
http://www.irtelectronics.com
I R T Electronics Pty Ltd A.B.N. 35 000 832 575
26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA
National: Phone: (02) 9439 3744 Fax: (02) 9439 7439
International: +61 2 9439 3744 +61 2 9439 7439
Email: sales@irtelectronics.com
Web: www.irtelectronics.com
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 2 of 9 16/07/2002
DVA-3004
Serial Digital Distribution Amplifier
Instruction Manual
Table of Contents
Section Page
Operational Safety 2
General Description 3
Functional Block Diagram 3
Applications 3
Specifications 4
Cicuit Description 5
Installation 6
Front & rear panel diagrams 7
Maintenance & Storage 8
Warranty and Service 8
Equipment return Error! Bookmark not defined.
Drawing List Index 9
This instruction manual applies to DVA-3004 assembly 804413 units later than S/N 0203001
Operational Safety:
WARNING
Operation of electronic equipment involves the use of voltages and currents that may
be dangerous to human life. Note that under certain conditions dangerous potentials
may exist in some circuits when power controls are in the OFF position.
Maintenance personnel should observe all safety regulations.
Do not make any adjustments inside equipment with power ON unless proper
precautions are observed. All internal adjustments should only be made by suitably
qualified personnel. All operational adjustments are available externally without the
need for removing covers or use of extender cards.
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 3 of 9 16/07/2002
General Description
The IRT DVA-3004 is a one in six out reclocking distribution amplifiers for SMPTE/EBU and ASI serial digital
video signals with all output signals in phase with the input signal, an added feature is a bypass circuit which will
switch the input circuit to output connector number 1 when the power supply of the unit is not present.
The units feature an input circuit with automatic cable equalisation for Belden 8281 or PFS1/2 coaxial cable and
cable driver circuits for seven individually sourced outputs, six to the rear connector panel and one for monitoring on
the front panel.
In addition the DVA-3004 allows the signal to be inverted if required by operation of a front panel slide switch to
select an inverted signal in the signal path from the input equaliser circuit.
Alarm circuits are provided which will provide remote monitoring of loss of the signal or the power supply via a
grounding relay contact, and a indication of the operation of the signal inversion circuit by means of a grounding
open collector transistor circuit.
The DVA-3004 is built in 3U extended Eurocard 220 mm x 100 mm module designed to mount in the IRT FRU-
3000 and FRU-1030 family of Eurocard frames.
Functional Block Diagram
Applications
The DVA-3004 is intended to be used where ASI or SDI serial digital signals may be present and multiple signal
outputs are required from equipment with only one output and to provide input cable equalisation for devices not
having this feature as most unequalised inputs will only support short input signal cable lengths.
In 270 Mb/s ASI signal circuits the DVA-3004 will provide the required in phase outputs needed to preserve the ASI
signal and provide the means of inverting the signal if other equipment in the line cause a inversion of the signal. The
input connector to output connector 1 bypass feature can preserve one main signal path in the event of power failure.
Alarm circuits are provided for external monitoring of the state of the signal inversion circuit and the power
fail/signal present circuit.
O/P 1
O/P 2
O/P 3
O/P 4
O/P 5
O/P 6
MON O/P
OUTPUTS
RL1-2
RELAY
RECLOCKING
EQUALISER DATA
RECOVERY
DATA FAIL
DETECTION
RL1-1
RELAY
INPUT
+V
INVERT
SIGNAL
Relay RL 1 = Power Fail Bypass
RelayRL 2 = Output Alarm
ALARM O/P
LINK
RL 2
BLOCK DIAGRAM DVA-3004 SIGNAL PATH
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 4 of 9 16/07/2002
Technical specifications
DVA-3004
Input:
Number 1.
Impedance 75 Ohm.
Return loss >15 dB 5 MHz to 360 MHz.
Outputs:
Number 7.
Signal level 800 mV ± 10%
Impedance 75 Ohm.
Return loss >15 dB 5 MHz to 360 MHz.
DC offset Nil.
Performance:
Cable compensation Automatic, better than 300 metres at 270 Mb/s
for Belden 8281 or equivalent cable.
Output rise time <1 ns, (700ps typically).
Connectors: BNC.
Indicators:
Power LED (green) DC.
Signal Present LED (green) SIG
270 Mb/s lock selected LED (green) 270
360 Mb/s lock selected LED (yellow) 360
Inverted signal LED (yellow) INV
Power requirement:
Voltage 28 Vac CT (14-0-14 Vac) or ±16 Vdc.
Consumption 2.5 VA (<80 mA).
General:
Temperature range 0 - 50° C ambient
Mechanical Suitable for mounting in IRT 19" rack chassis
types FRU-3000 & FRU-1030 with input, output and
power connections to the rear.
Size 6 HP x 3U Extended Eurocard (220 mm x 100 mm).
Weight With rear assembly 330g.
Finish:
Front panel Grey enamel, silk screened black lettering
& red IRT logo.
Rear assembly Detachable silk screened PCB with direct mount
connectors to Eurocard and external signals.
Standard accessories: Rear connector assembly (supplied with module).
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 5 of 9 16/07/2002
Circuit Description
The input circuit again consists of U1 a CLC014 adaptive cable equaliser IC, which automatically adapts to equalise
any cable length from zero metres to lengths that attenuate the signal by 40dB at 200MHz. This corresponds to 300
metres of Belden 8281 cable. A carrier detect and output mute circuit in the CLC014 is used to mute the output when
no signal is present. The CLC014 is insensitive to the pathological patterns that can be present in the serial digital
video signal.
The output of the CLC014 input stage is coupled to U2 a ECL multiplexer which can be switched to select a normal
or inverted signal stream to U3 a CLC016 data re-timing PLL with automatic rate selection. The CLC016 is set up
for manual rate selection of the serial data rates of 270 and 360 Mb/s using links LK3 and LK4. As with (the
CLC014 input stage) the carrier detect and mute circuit of U2 is used to mute the output when no signal is present.
U3 the CLC016 has a low residual output jitter of less than 170 ps p-p at 270 Mb/s and is insensitive to the
pathological patterns that can be present in the serial digital video signal.
The output of the CLC016 re-timing stage is coupled to CLC007 cable driver circuits U4,U5,U6 and U7 to provide
the seven isolated outputs from the DVA-3004. A relay RL1 wired in a change-over configuration is wired in the
input signal path and the signal path to output 1 on the rear panel, with this relay energised by the +5 volts supply the
input and output circuits are completed to provide normal operation of the DVA-3004. When +5 volts supply is not
present the relay will switch the input signal to output 1 on the rear panel to provide a fail safe circuit for the signal.
Note the cable driver outputs are wired so that all outputs are in phase with the input signal of the DVA-3004 when
the front panel slide switch is in the NORMAL position.
IC U8 provides the necessary LED drivers and logic to decode the rate detection indications from U3. LED LD5 is
used to indicate the state of the carrier detect circuit, indicating the presence of signal to the re-timing IC U3, and
LED’s LD3 and LD2 are used to indicate PLL rate of 270 Mb/s or 360 Mb/s signal by U3.
Monitoring circuits are provided to indicate loss of signal or power to the unit and the state of the signal inversion
circuit of the DVA-3004. Monitoring of loss of signal or power this is done by a relay RL2 which is energised when
signal is detected by the reclocking IC U3, the relay contact is set by LK2 to provide a contact closure to ground on
failure. The state of the front panel switch is monitored by U9 a opto-isolator circuit whose output is a npn transistor
with the emitter grounded, this transistor will be switched to ground when the signal inversion switch is switched to
INVERT.
The dual AC inputs are rectified by D1 to D4, and then regulated in a LM2575-5 switch mode regulator circuit U10
to provide the +5V operating voltage for the unit.
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 6 of 9 16/07/2002
Installation
Pre-installation:
Handling:
This equipment may contain or be connected to static sensitive devices and proper static free handling precautions
should be observed.
Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures
should be followed when inserting or removing cards from these bags.
Power:
AC mains supply: Ensure that operating voltage of unit and local supply voltage match and that
correct rating fuse is installed for local supply.
DC supply: Ensure that the correct polarity is observed and that DC supply voltage is maintained
within the operating range specified.
Earthing:
The earth path is dependent on the type of frame selected. In every case particular care should be taken to ensure that
the frame is connected to earth for safety reasons. See frame manual for details.
Signal earth: For safety reasons a connection is made between signal earth and chassis earth. No attempt should be
made to break this connection.
Installation in frame or chassis:
See details in separate manual for selected frame type.
Ensure that the front panel slide switch is in the NORMAL position for correct operation with ASI signals.
LK3 and LK4 set the PLL lock frequency of U3. LK3 is used to switch between 270 Mb/s (link closed) and 360
Mb/s (link open). LK4 is not fitted, it may be fitted if operation at 143 Mb/s or 177 Mb/s if desired.
LK3 LK4 RATE SELECTED
Closed Open 270 Mb/s
Open Open 360 Mb/s
Closed Closed 143 Mb/s
Open Closed 177 Mb/s
Link LK2 sets the operation of RL2 contact set, the position closest to the board edge is the normally closed position
which will give a contact closure to ground on a signal or power failure, this is the preferred position for common
alarm circuits from a number of units.
The presence of the internal +5 Vdc supply is indicated by the front panel LED (green).
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 7 of 9 16/07/2002
Front & rear panel diagrams
The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of
connectors, indicators and controls only.
DC
360 INV
270 SIG
DVA-3004
N140
OUTPUT MON
INVERT
NORMAL
J1
SK8
BYPASS ON POWER FAIL
O/P5
O/P3
O/P1
O/P6
OUTPUTS
OUTPUTS
1
2
1=GND
2=SIGNAL/POWER LOSS
3
3=SIGNAL INVERSION
O/P2
DVA-3004
INPUT
O/P4
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 8 of 9 16/07/2002
Maintenance & storage
Maintenance:
No regular maintenance is required.
Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind.
This is especially important in fibre optic equipment where cleanliness of optical connections is critical to
performance.
Storage:
If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed
plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be
included to deter corrosion.
Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures
should be followed when inserting or removing cards from these bags.
Warranty & service
Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary
conditions apply under a particular contract of supply. For situations when “No Fault Found” for repairs, a
minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not.
Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on
components shall be extended by IRT only to the extent obtainable from the component supplier.
Equipment return:
Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If
possible, confirm this by substitution.
Before returning equipment contact should be made with IRT or your local agent to determine whether the
equipment can be serviced in the field or should be returned for repair.
The equipment should be properly packed for return observing antistatic procedures.
The following information should accompany the unit to be returned:
1. A fault report should be included indicating the nature of the fault
2. The operating conditions under which the fault initially occurred.
3. Any additional information which may be of assistance in fault location and remedy.
4. A contact name and telephone and fax numbers.
5. Details of payment method for items not covered by warranty.
6. Full return address.
7. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether
the equipment is within the warranty period or not.
Please note that all freight charges are the responsibility of the customer.
The equipment should be returned to the agent who originally supplied the equipment or, where this is not
possible, to IRT direct as follows.
Equipment Service
IRT Electronics Pty Ltd
26 Hotham Parade
ARTARMON
N.S.W. 2064
AUSTRALIA
Phone: 61 2 9439 3744 Fax: 61 2 9439 7439
IRT Communications
www.irtcommunications.com

3004-dva.ib.doc Page 9 of 9 16/07/2002
Drawing List Index
Drawing # Sheet # Description
804413 1 DVA-3004 serial digital VDA schematic diagram.
804413 2 DVA-3004 serial digital VDA schematic diagram.
804413 3 DVA-3004 serial digital VDA schematic diagram.
IRT Communications
www.irtcommunications.com

Title
SCALE
SIZE
Sheet
DRAWN
CHECKED
ENG. APP.
Revision:
DO NOT COPY NOR
DISCLOSE TO ANY
THIRD PARTY
WITHOUT WRITTEN
CONSENT
of1
IRT Electronics Pty. Ltd.
Drawing No.
COPYRIGHT
ARTARMON NSW AUSTRALIA 2064
A3
N.T.S. 3
DVA-3004
804413
Date: 6
4-Apr-2002
RECLOCKING SERIAL D.A.
K.N.
1 23-03-00
+5V
+5V
+5V
(OUTPUTS)
PCB 804414
GND
+5V
SDO
SDODDI
DDI
ALARM
INV
Reclocking circuit
804413s2.sch
+5V
INPUT
J2/RA optional power in
(used when fitted to FRU-1030 frame)
C3
100nF
C1
100nF
C2
100nF
C4
100pF
C7 100nF
C8 4u7
L2
470nH
C37 4u7
21 D6
BAS32
2 1
R30 75
2 1
R31 75
C33 100nF
Q0 1
VCC
8
Q1 4
Q1 3
Q0 2
VEE
5
IN-
6
IN+
7
U4
CLC007AJE
21
R2
100
21
R1
71R5
VCC
1DO 14
AEC-
7
AEC+
6
CD
5
VCC
4
OEM
3
VCC
2
DI 8
DI 9
VEE 10
VEE 11
MUTE 12
DO 13
U1
CLC014AJE
2 1
R23 100
2 1
R22 100
2 1
R29 100
2 1
R28 100
21
R3
120 Q0 1
VCC
8
Q1 4
Q1 3
Q0 2
VEE
5
IN-
6
IN+
7
U6
CLC007AJE
C38 4u7
C40 4u7
C41 4u7
C43 4u7
C45
4u7
2 1
R34
68
2 1
R35
68
2 1
R37
68
2 1
R38
68
2 1
R40
68
21 R42
66R5
C31
4u7
2 1
R26
100
2 1
R27
100
2 1
R32
68
C27
4u7
C28
10nF
Q0
1VCC 8
Q1
4
Q1
3
Q0
2
VEE 5
IN- 6
IN+ 7
U7
CLC007AJE
L1/RA
L2/RA
1
2
3SK8
1
2
3
J2
21 R33
150
Q0 1
VCC
8
Q1 4
Q1 3
Q0 2
VEE
5
IN-
6
IN+
7
U5
CLC007AJE
21 R2/RA
L3/RA
21 R3/RA
L5/RA
21 R5/RA
L4/RA
21 R4/RA
L7/RA
21 R7/RA
L6/RA
21 R6/RA
1
2
3
4
5
6
7
8
9
10 13
14
15
16
17
18
19
20
21
22
RL1
G5Y-254P 5V
2 1
R25 100
2 1
R24 100
C34 100nF
C35 100nF
C32
100nF
21
R1/RA
2 1
D7
BAS32
+5V C29
100pF
C5
100pF
C6
100pF
2 1
R36
150
C39 10nF
2 1
R39
150
C42 10nF
2 1
R41
150
C44
10nF
C30 100nF
21
JP2 0R0
SW1
INVERT
SIGNAL
21
R50
10R
+5V
21
LD4
yell
21 R46
470
12
65
7
U9
IL207 L6
BEAD C47
10nF
C50
10nF
21 R51
470
INVERT
2 1
D9
BAS32
L1
15nH
L1-7/RA = 15nH
R1-7/RA = 68R
2 13-07-00 ECR1109
3 13-09-00 ECR1127
5 8-03-01 ECR1188
4 4-12-00 ECR1152
6 16-10-01 ECR1273
PLL set to manual rate sel.
1A
1B
2A
2B
3A
3B
4A
4B
5A
6A
6B
7A
7B
8A
8B
10A
10B
5B
11A
11B
12A
12B
13A
13B
14A
15A
15B
17A
17B
18A
18B
9A
9B
20A
20B
14B
21A
21B
22A
22B
23A
24B
24A
25B
26A
27A
27B
28A
23B
19A
19B
30A
30B
26B
31A
31B
32A
32B
25A
16A
16B
28B
29A
29B
P1
DIN64RA
1A
1B
2A
2B
3A
3B
4A
4B
5A
6A
6B
7A
7B
8A
8B
10A
10B
5B
11A
11B
12A
12B
13A
13B
14A
15A
15B
17A
17B
18A
18B
9A
9B
20A
20B
14B
21A
21B
22A
22B
23A
24B
24A
25B
26A
27A
27B
28A
23B
19A
19B
30A
30B
26B
31A
31B
32A
32B
25A
16A
16B
28B
29A
29B
J1
DIN64
AC1
AC2
AC3
AC4
+5V
GND
Power Supply Circuit
804413s3.sch
+5V
2 1
JP1
0R0
+5V
O/P5
O/P6
O/P3
O/P4
O/P2
O/P1
SK9
MON. O/P
IRT Communications
www.irtcommunications.com

Title
SCALE
SIZE
Sheet
DRAWN
CHECKED
ENG. APP.
Revision:
DO NOT COPY NOR
DISCLOSE TO ANY
THIRD PARTY
WITHOUT WRITTEN
CONSENT
of2
IRT Electronics Pty. Ltd.
Drawing No.
COPYRIGHT
ARTARMON NSW AUSTRALIA 2064
A3
N.T.S. 3
DVA-3004
804413
Date: 6
4-Apr-2002
RECLOCKING SERIAL D.A.
K.N.
1 23-03-00
DDI
DDI
SDO
SDO
GND
+5V
+5V
+5V
SIGNAL
+5V
+5V
+VA
+5V
+5V
ALARM
PRESENT
270 Mb/s
360 Mb/s
21 R45
820
21 R48
820
21 R47
820
1
32
Q2
BC846
21
R10
10K
C23
100nF
21
R4
82
21 D5
BAS32
21
R5
82
C25
100pF
L4
470nH
21 R17
510
C20 82pF
C21
100nF
DDI
5SDO 25
DDI
6
SCO 22
SCO 23
SDO 24
VCC 7
VCC 26
R0 13
R3 17
VEE
11
VEE
1
VEE
27
VEE
3
VC
12
FD
10
VC
9
R1 14
R2 15
RTN 18
RD1 21
RD0 20
CD
19
MUTE
28
CARS
2
SER
4
ACQ/WR
8
AUTO
16
U3
CLC016A
21 R19 5K49
21 R18 6K81
21 R20 3600
21 R21 2K55
2 1
R12
22K
21
LK1
2 1
R13
220K
C12
100nF
31
2
LK2
2 1
D8
BAS32 C10
4u7
1
32
Q1
BC846
4
5
6
U8B
74HC00
1
2
3
U8A
74HC00
12
13
11
U8D
74HC00
9
10
8
U8C
74HC00
21
LD3
grn
21
LD5
grn
21 JP3 0R0
21
JP4 0R0
+5V
INV
C14
100nF
C18
10nF
C24
100pF
2 1
R14
470
2 1
R15
470
21
LD2
yell
L5
BEAD
C46
10nF
C48
10nF
2 1
R11
560
21
R8
1K2
2 1
R7
4K7
21
R9
1K2
C11
100nF
1
32
Q3
BC846
+5V +5V
C49
10nF
C16
100pF C26
100nF
2 13-07-00 ECR1109
D0
2
D1
3
D1
4
D2
5
D2
6
D3
7
D3
8VEE 9
VBB2 10
VBB1 11
Q12
Q13
SEL1 14
SEL0 15
VCC 16
D0
1U2
MC100EL57D
C13
4u7
3 13-09-00 ECR1127
4 4-12-00 ECR1152
21
R52
100R
5 8-03-01 ECR1182
+VA 21 R54 10K
21
R53 10K
2 1
LK4
2 1
LK3
+5V
6 16-10-01 ECR1273
PLL set to manual rate sel.
closed R2 = 270 Mb/s
open R3 = 360 Mb/s
open
open
Rate SelectedLK3 LK4
38
RL2A
V23026
10
15
RL2B
VCC
Reclocking Circuit
21
3Q4
BAV70
(A4)
(1B) (1B)
(1B)
IRT Communications
www.irtcommunications.com

Title
SCALE
SIZE
Sheet
DRAWN
CHECKED
ENG. APP.
Revision:
DO NOT COPY NOR
DISCLOSE TO ANY
THIRD PARTY
WITHOUT WRITTEN
CONSENT
of3
IRT Electronics Pty. Ltd.
Drawing No.
COPYRIGHT
ARTARMON NSW AUSTRALIA 2064
A3
N.T.S. 3
DVA-3004
804413
Date: 6
4-Apr-2002
RECLOCKING SERIAL D.A.
K.N.
1 23-03-00
AC1
AC2
AC3
AC4
+5V
2 1
D10
1N5822 C53
220uF
I
1F4
O2
EN
5
G
3
U10
LM2575-5.0
21 F1
4R7
21 F2
4R7
21 F3
4R7
21 F4
4R7
2 1
D1
S1B
2 1
D2
S1B
2 1
D3
S1B
2 1
D4
S1B
C51
1000uF C52
100uF C54
220uF
L9
22uH
L8
470uH
1 3
2
FL1
1 3
2
FL2
1 3
2
FL3
1 3
2
FL4
L7
22uH
C9
100nF
2 13-07-00 ECR1109
3 13-09-00 ECR1127
5 8-03-01 ECR1188
4 4-12-00 ECR1152
6 16-10-01 ECR1273
PLL set to manual rate sel.
Power Supply Circuit
'DC'
grn
21
R49
820
21
LD1
+5V
+5V
GND
+5V
6G
IRT Communications
www.irtcommunications.com
Table of contents