ISHIDA IWX-150/30 User manual

Manual No. 0149A
・Do not carry out installation, operation, service or mainte-
nance until thoroughly understanding the contents of this
manual.
・Keep this manual available at all times for installation, oper-
ation, service, and maintenance. ISHIDA CO., LTD.

IWX Operation Manual Kg Version Manual No. 0149A
You can help improve this manual by call-
ing attention to errors and by recommend-
ing improvements.
Please convey your comments to the near-
est Ishida Company regional representa-
tive.
Thank you!
Copyright c 2001 by Ishida Co., Ltd. All Rights Reserved.
No part of this manual may be reproduced in any form, by mimeograph or any
other means, without written permission of the publisher.

Manual No. 0149A IWX Operation Manual Kg Version
SAFETY CONSIDERATIONS
To ensure the safe operation of this machine, the general safety considerations below must be followed:
Grounding
This instrument is a Class 1 device which requires protective grounding for safe operation.
To avoid potential shock hazards, a protective grounding conductor for the instrument must be securely connected
to the main grounding provision by qualified service personnel.
Do not remove covers or enclosures.
To avoid personal injury and shock, do not open or remove any covers or enclosures of the instrument unless
specified in the manual.
Do not perform unspecified maintenance.
For your own personal safety, do not perform any maintenance procedures which are not specified in the manual.
Diconnect the power supply before servicing.
To ensure your personal safety, disconnect the power supply before servicing.
Power supply to the machine is disconnected only when the electrical
plug is removed from the electrical outlet. For safe operation of this
machine, connect the plug to the nearest and most accessible outlet.
The following symbols are used to alert service personnel of potential danger or
special circumstances related to the safe and proper servicing of this machine:
Precautions which must be followed to prevent the possibility of death or
serious injury.
Precautions which must be followed to prevent the possibility of light or
moderately severe injury to personnel or damage to the equipment.
Important information for the operation of the machine.

IWX Operation Manual Kg Version Manual No. 0149A
1) Always operate the scale with the same rated AC power supply shown
on the specification plate.
2) To disconnect the power supply, remove the electrical plug from the
electrical outlet.
CAUTIONS FOR USE
Always operate the scale on a level surface.
Do not drop or apply a strong shock to the
scale.
Do not expose the scale to direct sunlight for
long period.
Do not disassemble the scale.
When cleaning the scale, only use a soft dry
cloth wetted with a neutral cleanser. Never
use thinner or other volatile liquids.
Do not allow any liquids to come into contact
with the scale.

Manual No. 0149A IWX Operation Manual Kg Version
Avoid Locating the Scale in the Following Places:
A place of low temperature, high temperature or high humidity
A place exposed to direct sunlight
A place frequently exposed to vibration
On an unstable floor or table.
A place directly exposed to wind, cold air, or hot air.
A place directly exposed to cold air from a cooler or refrigerator. A place exposed to hot air from an air condi-
tioner or heater. A place exposed to wind from a fan or other pneumatic device.
A dusty place
A place provided with fluctuating power supply voltage
Use of an electrical outlet also being used for a vibrator, radio, or other noise sources may affect the performance
of the scale. Be sure to provide an outlet exclusively for use by the scale. Also avoid putting many loads on one
electrical outlet.
Power Supply
Use a power supply that conforms to product specifications.
Provide a power line to be exclusively used for the scale.
If the power supply voltage fluctuates, the scale may malfunction.
Do not tread on or place a heavy load on the power cable.
The cable will be damaged. Continued use of the cable under such conditions may lead to an accident or prob-
lems with the scale.
Be sure to ground the scale to avoid electrical leakage and malfunction.

Manual No. 0149A IWX Operation Manual Kg Version
1. Before Using Your Scale . . . . . . . . . . . . . . . . . . . . 7
1-1 Cautions for Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2. Name and Function of Each Component . . . . . . . 8
2-1 External View of the Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2-2 Function of Each Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3. Preparing the Scale . . . . . . . . . . . . . . . . . . . . . . . . 9
3-1 Fitting the Display Pole and Setting Up the Scale . . . . . . . . . . 9
3-2 Vertical Adjustment of the Display Unit . . . . . . . . . . . . . . . . . . 12
4. Weighing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5. Tare Key-in Mode . . . . . . . . . . . . . . . . . . . . . . . . . 15
6. Confirming the Tare . . . . . . . . . . . . . . . . . . . . . . . 17
7. Using the Preset Function . . . . . . . . . . . . . . . . . . 18
7-1 Presetting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7-2 Calling the Preset Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. Setting Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8-1 Setting Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8-2 Set Values List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9. Routing Servicing and Cleaning . . . . . . . . . . . . . 29
9-1 Routine Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
9-2 Cleaning Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10. Troubleshooting Guide . . . . . . . . . . . . . . . . . . . 30
11. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table of Contents

Manual No. 0149A IWXOperation Manual Kg Version 7
• Do not disassemble or reconstruct
your scale.
Incorrect disassembly may lead to scale failure.
Reconstructing the scale, disassembling part(s), or
fitting unspecified part(s) may cause serious acci-
dents or personal injuries. If disassembled or recon-
structed the scale may not be allowed to be reused as
an approved scale.
• Do not use your scale in abnormal
conditions.
If smoke, disgusting smell, or any other abnormality
is detected from the scale, immediately disconnect
the power supply cable plug from the outlet and con-
tact the nearest ISHIDA regional representative for
repair. Continued use of the scale under such abnor-
mal conditions may cause a fire or electric shock.
For your personal safety, never repair the scale by
yourself.
• Your scale is a precision machine. Do
not give the scale any shock.
The scale may be impaired or its weighing perfor-
mance may be deteriorated.
• Do not insert/remove the plug in/from
the outlet with wet or dirty fingers.
An electric shock or short-circuit may occur.
• Do not remake the electrical plug or
power cable.
A fire or electric shock may occur.
• Do not pull strongly, break, or remake
the power cable.
The core wires may be cut and cause a fire, electric
shock, or defective functioning of the scale.
• Be sure to insert the load cell into the
display pole.
• Do not pour an excessive amount of
water or high pressure water on the
scale.
• Do not leave any items on the weigh-
ing platter.
• Before using the scale, be sure to
level the scale body.
Otherwise, the scale may malfunction.
• Never use thinner or other volatile
agent for servicing the scale.
Discoloration may result. Wipe the scale body gen-
tly with a soft dry cloth, or use a neutral detergent.
• When carrying the scale, be sure to
hold it at the bottom.
Do not move the scale by holding only the display
unit or display pole.
• Never peel off the seal affixed to the
scale body.
1. Before Using Your Scale
1-1 Cautions for Handling

8IWX Operation Manual Kg Version Manual No. 0149A
2-1 External View of the Scale
Used to turn ON/OFF display function of scale.
The key turns ON or OFF the display function of the scale. Power to the scale is
still active even when the key is switched OFF. When moving the scale or leaving it
for a long period without use, be sure to disconnect the power by removing the electri-
cal plug from the outlet.
(1) Used for zero adjustment to reset weight indicator to zero.
(2) Used to switch numeric values to the positive side when registering and setting them.
(1) Used to set tare weight.
(2) Used to switch numeric values to the negative side when registering and setting them.
(1) Used to conform and display the tare weight.
(2) Used to print out the subtotal when a printer is connected.
(3) Used to shift the flashing digit during registration and setting.
(1) Used to print out the weight when a printer is connected.
(2) Used to conform and display the data being called in the preset mode.
(3) Used to call the registered tare weight and its upper and lower limits.
2-2 Function of Each Key
2. Name and Function of Each Component

Manual No. 0149A IWX Operation Manual Kg Version 9
3-1 Fitting the Display Pole and Setting Up the Scale
The display unit and display pole are fitted together with a tightening knob. The display pole
and the bracket pipe base are separated.
1. Remove the Bracket Pipe.
Remove the bracket pipe from the bracket pipe base (by loosening the four hex head
screws).
2. Pass the Load Cell Cable through the Display Pole.
Push the extra length of cable protruding from the bracket pipe base into the display pole.
Do not pull strongly on the load cell cable
when pushing it into the display pole. Other-
wise, it may be cut.
If the cable covering material is scratched,
water may penetrate into the cable and cause
unreliable weighing, or the core material may
corrode and cause the scale to fail.
3. Stand the Display Pole against the Bracket Pipe Base.
Stand the display pole against the bracket pipe base by fitting it at its load cell cable side into
the tongue of the bracket pipe base.
3. Preparing the Scale
The following describes the procedure for preparing the scale before operation.

10 IWX Operation Manual Kg Version Manual No. 0149A
4. Fix the Display Pole with the Bracket Pipe.
After confirming the screw holes are aligned, fix the display pole to the scale body with the
bracket pipe (at four points with plain washers and hex head screws).
Fit the bracket pipe with its larger radius cor-
ners facing upward. Securely tighten the
screws until the display pole becomes steady.
5. Store the Load Cell Cable inside the Display Pole.
Fold up the extra length of load cell cable and store it inside the display pole.
Push the load cell cable deeply into the dis-
play pole at least 15 mm away from the pole
end.
6. Install the Weighing Platter.
Make sure that nothing has been placed on the
weighing platter.

Manual No. 0149A IWX Operation Manual Kg Version 11
7. Level the Scale.
Adjust the level adjustable feet until the air bubble inside the level remains at the center of
the circle.
8. Supply the Power
Insert the power supply plug into the outlet. Ground the plug if the scale will be used in a
place with a chance of electrical leakage or static electricity or in such an area exposed to
electrical noise as the vicinity of an electric motor.
To disconnect the power supply, remove the
electrical plug from the electrical outlet.
9. Turn on the Power Switch.
With nothing placed on the weighing platter, press the key.
The display unit will turn on.
Make sure that display indicates all "0"s.

12 IWX Operation Manual Kg Version Manual No. 0149A
10. Adjust the Zero Point.
When no zero-point mark ( ) is displayed, press the key.
3-2 Vertical Adjustment of the Display Unit
After loosening the display unit tightening knob, adjust the unit at an easy-to-see angle.
Then, retighten the knob.

Manual No. 0149A IWX Operation Manual Kg Version 13
1. Turn ON the Power Switch.
With nothing placed on the weighing platter, press the key.
The display unit will turn on.
Make sure that the display
indicates all "0"s.
2. Subtract the Tare.
After placing a tare container on the weighing platter, press the key.
The tare can also be sub-
tracted by the following
procedure.
- Call the preset value.
- Set the tare to the tare
key-in mode.
4. Weighing

14 IWX Operation Manual Kg Version Manual No. 0149A
3. Weigh an Item.
Place the item to be weighed on the weighing platter together with the tare weight.
* When the upper and lower limit values have been set, the following will be displayed.
Weighing
result Weighing condition Indication on scale (When the built-in buzzer is set to distin-
guish between the upper and lower limits)
Over Weight > upper limit weight (beep, beep, beep,---)
Accept Lower limit weight ≤ weight
≤upper limit weight (beep-----)
Under Weight < lower limit weight (beep---, beep---, beep---)

Manual No. 0149A IWX Operation Manual Kg Version 15
1. Switch to the Tare Key-in Mode.
After confirming the scale is in a stable condition with nothing on the platter, press the
key for two seconds.
2. Set the Tare.
Move the flashing digit by pressing the key, and press the key or key
to key in the tare.
- For a tare of 0.8 kg:
×3 ×2
5. Tare Key-in Mode

16 IWX Operation Manual Kg Version Manual No. 0149A
3. Press the Key.
The tare will be set.

Manual No. 0149A IWX Operation Manual Kg Version 17
1. Confirm the Tare during Weighing Operation.
To confirm the preset tare, press the key.
- For a tare of 0.08 kg:
6. Confirming the Tare

18 IWX Operation Manual Kg Version Manual No. 0149A
7-1 Presetting
1. With the Power Supply Turned OFF, Press the Key.
Then Press the Key.
Preset No. 1 will be displayed.
Press the key while all
displays are ON (while the
buzzer is sounding).
2. Select the Preset No. to Set.
To select the preset No., press the key or key.
Press the key.
The tare for weighing range A of the preset No. will be displayed.
Pressing the key will increase the preset No., while pressing the key will
decrease it.
7. Using the Preset Function

Manual No. 0149A IWX Operation Manual Kg Version 19
3. Set the Tare for Weighing Range A.
Move the flashing digit by pressing the key. Then key in the tare for weighing range
A by pressing the key or key.
- For a tare of 0.25 kg:
×3 ×2
×1 ×5
Press the key.

20 IWX Operation Manual Kg Version Manual No. 0149A
4. Set the Tare for Weighing Range B.
Move the flashing digit by pressing the key. Then key in the tare for weighing range
B by pressing the key or key.
- For a tare of 0.3 kg:
×4 ×3
Press the key.
The flashing digit will be
displayed at the position
where the key is
pressed for setting the tare
for weighing range A.
5. Set the Upper Limit Value.
Move the flashing digit by pressing the key. Then key in the upper limit value by
pressing the key or key.
- For an upper limit value of 1 kg:
×4 ×1
Press the key.
If the lower limit value has
already been preset, only
values equal to or larger
than this limit value can be
set.
The flashing digit is dis-
played at the position
where the key is
pressed for setting the tare
in the weighing range B.
Other manuals for IWX-150/30
1
Table of contents
Other ISHIDA Scale manuals

ISHIDA
ISHIDA IGB Series User manual

ISHIDA
ISHIDA SR-2000 alpha User manual

ISHIDA
ISHIDA iwq-150/30 User manual

ISHIDA
ISHIDA Uni-5 User manual

ISHIDA
ISHIDA BC-4000 User manual

ISHIDA
ISHIDA MTE-300 User manual

ISHIDA
ISHIDA IWQ-150 User manual

ISHIDA
ISHIDA INS-100 User manual

ISHIDA
ISHIDA AC-4000H User manual

ISHIDA
ISHIDA AC-4000 Series User manual

ISHIDA
ISHIDA IP-EMZ User manual

ISHIDA
ISHIDA SR-2000a Manual

ISHIDA
ISHIDA SR-2000 alpha Manual

ISHIDA
ISHIDA IPC-WP User manual

ISHIDA
ISHIDA IGX Series User manual

ISHIDA
ISHIDA IP-EMZ User manual

ISHIDA
ISHIDA Uni-3 User manual

ISHIDA
ISHIDA UNI-7 User manual

ISHIDA
ISHIDA Astra User manual

ISHIDA
ISHIDA IPC 3kg User manual