ISHIDA IGX Series User manual

Platform Scale
IGX/IGB Series
Asia/Oceania/EU Specification
Operation Manual
IGX Series IGB Series
IMPORTANT
•Do not carry out installation, operation, service, or
maintenance until thoroughly understanding the
contents of this manual.
•Keep this manual available at all times for installation,
operation, service, and maintenance.
Manual No. 0203A

PREFACE
Thank you for purchasing an Ishida IGX/IGB Series.
The IGX/IGB Series is a high-performance Platform Scale that weighs items precisely.
This manual explains the operation procedures, cautions for use, etc. of the IGX/IGB Series.
Please read this manual fully so that you can use the IGX/IGB Series safely and effectively.
Failure to follow the instructions in this manual may result in loss or serious injury, damage to the
machine or faulty operation.
NOTE This product cannot be used for certifying weight transactions.
yNo part of this manual may be reproduced in any form, by mimeograph or any other means,
without written permission of the publisher.
yDesign and specifications are subject to change without notice.
yThere may be cases where the contents of this manual may not conform to the actual operations
due to modifications to the machine or other reasons.
yPlease convey your comments to your nearest Ishida dealer should you notice any errors or
discrepancies in the contents of this manual.
Copyright ©2003 by Ishida Co., Ltd. All Rights Reserved.
No part of this manual may be reproduced in any form, by mimeograph or any other means, without
written permission of the publisher.
IGX/IGB Series Operation Manual No. 0203A

CONTENTS
Chapter 1 BEFORE OPERATING MACHINE................................................... 1
1.1 Caution for Handling............................................................................ 2
1.2 Name and Function of Each Part........................................................ 4
1.3 Installation........................................................................................... 5
1.4 Start and Stop of Operation................................................................. 7
1.5 Daily Care............................................................................................ 8
Chapter 2 PRESET FUNCTION........................................................................ 9
2.1 Presetting the Values......................................................................... 10
2.2 Calling Up the Preset Values............................................................. 14
Chapter 3 WEIGHING ..................................................................................... 17
3.1 Weighing Non-PLUs.......................................................................... 18
3.2 Weighing PLUs.................................................................................. 19
Chapter 4 SETTING MODE............................................................................. 23
4.1 Setting Method .................................................................................. 24
4.2 Set Values List................................................................................... 26
Chapter 5 BATTERY CHECK.......................................................................... 29
5.1 Checking Battery Voltage.................................................................. 30
Chapter 6 APPENDIX ..................................................................................... 33
6.1 Troubleshooting................................................................................. 34
6.2 Specifications .................................................................................... 35
IGX/IGB Series Operation Manual No. 0203A page i

1
BEFORE OPERATING MACHINE
BEFORE
OPERATING
MACHINE
1
IGX/IGB Series Operation Manual No. 0203A page 1

1.1 Caution for Handling
1.1 CAUTION FOR HANDLING
Safety Considerations
To ensure the safe operation of this machine, the general safety considerations below must be
followed:
Grounding
To avoid potential shock hazards, a protective grounding conductor for the machine must be
securely connected.
Do not disassemble or modify the machine
Doing so may result in physical injury or damage to the machine.
Do not remove covers or housing
To avoid personal injury and shock, do not open or remove any covers or casing of the machine
unless specified in this manual.
Do not perform unspecified maintenance
For your own personal safety, do not perform any maintenance procedures which are not specified
in this manual.
Disconnect the power supply before servicing
To ensure your safety, disconnect the power supply before servicing.
Symbols Used in This Manual
This manual uses the following symbols to emphasize important information. Fully understanding
the meaning of the symbols will facilitate the use of this manual.
Symbol Meaning
Indicates information that, if not heeded, could result in faulty operation, damage to
the machine, or relatively serious injury.
Symbol Meaning
NOTE Indicates additional information of particular importance.
Indicates information to help your understanding of the related text.
Indicates a page to refer to.
page 2 IGX/IGB Series Operation Manual No. 0203A

1.1 Caution for Handling
Avoid Locating the Machine in the Following Places
1
BEFORE OPERATING MACHINE
A place subject to high temperature or high
humidity.
A place exposed to direct sunlight or direct
cold air.
A place where water or other liquids may be
spilled on the machine.
A place subject to a lot of dust or dirt.
A place subject to strong wind.
A place where the floor or ground is not level
or unstable.
Power Supply
Always operate the machine with the specified AC
voltage.
IGX/IGB Series Operation Manual No. 0203A page 3

1.2 Name and Function of Each Part
1.2 NAME AND FUNCTION OF EACH PART
Appearance
IGX Series IGB Series
Display Unit (Asia/Oceania Specification)
IGX Series IGB Series
Display Unit (EU Specification)
IGX Series IGB Series
Used to turn the power on or off.
or Used to set the scale weight to zero, or increase the value on the
display.
or Used to set the tare weight, or decrease the value on the display.
or Used to move the digit position or finish a setting procedure.
or Used to determine or call-up the setting.
page 4 IGX/IGB Series Operation Manual No. 0203A

1.3 Installation
1.3 INSTALLATION 1
BEFORE OPERATING MACHINE
Assembling the Scale
1Remove the two hex-headed bolts from the
bottom of the display pole.
2Carefully insert the bottom of the display pole
into the base bracket while pulling out the slack
in the cables.
CAUTION
If the cable insulation is damaged, water may penetrate into the cable and cause
inaccurate weighing, or the core material may corrode, causing the scale to fail.
3Tighten the two hex-headed bolts with an Allen
wrench.
4Bundle the excessive cables with a clamp so as
to prevent cable damage.
IGX/IGB Series Operation Manual No. 0203A page 5

1.3 Installation
5Carefully carry and place the Weigh Platter over
the Platter Support.
Leveling the Scale
Use the level adjuster until the air bubble inside the level is positioned in the center of the circle.
Adjusting the Display Unit Angle
After loosening the display unit tightening knob, adjust the unit to an easy-to see angle. Then
re-tighten the knob.
page 6 IGX/IGB Series Operation Manual No. 0203A

1.4 Start and Stop of Operation
1.4 START AND STOP OF OPERATION 1
BEFORE OPERATING MACHINE
This section explains how to start and stop the machine operation.
Starting Machine Operation
1 Make sure that nothing is placed on the weigh platter.
2 Press the ON/OFF key to turn on the power. Then, the self-diagnostic display appears and
all display segments are lit.
IGX Series IGB Series
Ä
M
3 ake sure that the initial display appears and the “ZERO” indicator lights.
IGX Series IGB Series
NOTE If the “ZERO” indicator is not lit, press the ZERO key.
Stopping Machine Operation
1 Press the ON/OFF key to stop the machine operation.
IGX Series IGB Series
Ä
NOTE When the scale has not been used for a long time, the scale will be automatically turned off.
IGX/IGB Series Operation Manual No. 0203A page 7

1.5 Daily Care
1.5 DAILY CARE
Daily care will ensure the long life of this machine, and can prevent potential trouble or failure. Also,
cleaning the machine after operation is recommended.
CAUTION
To ensure your personal safety, disconnect the power plug from the outlet before
any servicing or cleaning.
Clean the outer surface of the machine with a soft cloth soaked with a water-diluted neutral
detergent. Then, wipe it with a soft and dry cloth.
`
CAUTION
Do not use thinner or chemicals other than a water-diluted neutral detergent.
page 8 IGX/IGB Series Operation Manual No. 0203A

2
PRESET FUNCTION
PRESET
FUNCTION
2
IGX/IGB Series Operation Manual No. 0203A page 9

2.1 Presetting the Values
2.1 PRESETTING THE VALUES
Selecting the PLU No.
W
1 hen the power is turned OFF,
IGX Series IGB Series
press the ON/OFF key, then the self-diagnosis display appears.
IGX Series IGB Series
Ä
Im
P
2 mediately press the SET key while all display segments are lit.
LU 1 will be displayed.
IGX Series IGB Series
Ä
3Repeat to press either the ZERO (+) or TARE (-) key until the desired PLU No. appears on
the display.
[Example] Selecting PLU 2
or
or
Ä
IGX Series
IGB Series
page 10 IGX/IGB Series Operation Manual No. 0203A

2.1 Presetting the Values
2
PRESET FUNCTION
Setting the Tare Weight
4Press the SET key to display the tare weight for the selected PLU.
IGX Series IGB Series
Ä
5Move the flashing digit to the desired position by pressing the COLUMN key.
IGX Series IGB Series
Ä
6Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then,
press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Tare weight 250g
or
or
ÄÄ
IGX Series
IGB Series
IGX/IGB Series Operation Manual No. 0203A page 11

2.1 Presetting the Values
Setting the Upper Limit Value
7Press the SET key to determine the tare weight and move to the display for setting the uppe
r
limit value.
Move the flashing digit to the desired position by pressing the COLUMN key.
IGX Series IGB Series
Ä
8Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then,
press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Upper limit value 1000g
or
or
ÄÄ
IGX Series IGB Series
Setting the Lower Limit Value
9Press the SET key to determine the upper limit value and move to the display for setting the
lower limit value.
Move the flashing digit to the desired position by pressing the COLUMN key.
IGX Series IGB Series
Ä
NOTE If the lower limit value has already been preset, only a value equal to or larger than
this limit value can be set.
page 12 IGX/IGB Series Operation Manual No. 0203A

2.1 Presetting the Values
10
Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then,
press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Lower limit value 500g
or
or
ÄÄ
IGX Series IGB Series
2
PRESET FUNCTION
Setting Values for Other PLUs
11
Press the SET key to determine the lower limit value.
Repeat steps 3 through 10 above for setting the values for other PLUs.
NOTE If the upper limit value has already been preset, only a value equal to or less than this
limit value can be set.
Finishing the Setting Procedures
P
12
ress the COLUMN key to finish the setting procedure.
IGX Series IGB Series
Ä
IGX/IGB Series Operation Manual No. 0203A page 13

2.2 Calling Up the Preset Values
2.2 CALLING UP THE PRESET VALUES
1Press and hold the SET key for two seconds.
“PLU 1” will be displayed.
IGX Series IGB Series
(2 sec.)
Ä
2Press the ZERO (+) or TARE (-) key to select the desired PLU No.
or
or
Ä
IGX Series IGB Series
3Press the SET key to display the tare weight, the upper limit value, and the lower limit value.
IGX Series IGB Series
Ä
b
b
b
b
page 14 IGX/IGB Series Operation Manual No. 0203A

2.2 Calling Up the Preset Values
2
PRESET FUNCTION
NOTE If no tare weight has been set, or if neither the upper limit value nor the lower limit
value has been set, the values set before pressing the SET key will remain active.
IGX/IGB Series Operation Manual No. 0203A page 15

MEMO
page 16 IGX/IGB Series Operation Manual No. 0203A

3
WEIGHING
WEIGHING
3
IGX/IGB Series Operation Manual No. 0203A page 17
This manual suits for next models
1
Table of contents
Other ISHIDA Scale manuals

ISHIDA
ISHIDA Uni-5 User manual

ISHIDA
ISHIDA Uni-5 User manual

ISHIDA
ISHIDA IWB Series User manual

ISHIDA
ISHIDA BC-4000 User manual

ISHIDA
ISHIDA INS-100 User manual

ISHIDA
ISHIDA UNI-7 User manual

ISHIDA
ISHIDA SR-2000 alpha User manual

ISHIDA
ISHIDA IPC-WP User manual

ISHIDA
ISHIDA Uni-3 User manual

ISHIDA
ISHIDA IWQ Series User manual

ISHIDA
ISHIDA SR-2000 alpha Manual

ISHIDA
ISHIDA IWQ-150 User manual

ISHIDA
ISHIDA iwq-150/30 User manual

ISHIDA
ISHIDA MTE-300 User manual

ISHIDA
ISHIDA BC-3000 User manual

ISHIDA
ISHIDA Astra II Bench Installation manual

ISHIDA
ISHIDA UNI-7 User manual

ISHIDA
ISHIDA IGB Series User manual

ISHIDA
ISHIDA BC-4000 User manual

ISHIDA
ISHIDA NOVA-II User guide