IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Worldwide
Contacts
www.tyco-fire.com
General
Description
The Series TY-B, 80 and 115 K-factor,
Conventional Sprinklers described in
this data sheet are special response -
standard coverage, decorative 4 mm
glass bulb sprinklers designed for use
in accordance with the installation rules
recognized by the applicable Approval
agency (e.g., VdS). These sprinklers are
intended to be installed either pendent
or upright, and in either position, they
produce a spherical water discharge
pattern with approximately 50% of
the discharge directed upwards and
approximately 50% of the discharge
directed downwards.
NOTICE
The Series TY-B Sprinklers described
herein must be installed and main-
tained in compliance with this docu-
ment, as well as with the applicable
standards recognized by the Approval
agency, in addition to the standards of
any other authorities having jurisdiction.
Failure to do so may impair the perfor-
mance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Numbers (SINs)
TY3641 . . . . . . . . . Conventional 80K
T Y46 41 . . . . . . . . .Conventional 115K
Technical
Data
Approvals
VdS Approved (CEA 4001)
Maximum Working Pressure
12,1 ba r
Discharge Coefficient
K = 80 LPM/bar½
K = 115 LPM/bar½
Temperature Ratings
57°C, 68°C, 79°C, 93°C, and 141°C
Finishes
Refer to Table A.
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze
Button . . . . . . . . . . . . . . . . . . . . . . Brass/Copper
Sealing Assembly ..Beryllium Nickel w/TEFLON
Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass
Compression Screw . . . . . . . . . . . . . . . . .Bronze
Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Copper
Operation
The glass bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Installation
The Series TY-B Sprinklers must
be installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1,6 mm for
the 57°C to 2,4 mm for the 141°C tem-
perature ratings.
A leak tight 1/2 in. NPT sprinkler joint
should be obtained with a torque of
9 to 19 N∙m. A leak tight 3/4 in. NPT
sprinkler joint should be obtained with
a torque of 13 to 27 N∙m. Higher levels
of torque may distort the sprinkler inlet
and cause leakage or impairment of the
sprinkler.
TFP663
Page 2 of 4
Do not attempt to make up for insuf-
ficient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-B Conventional Sprin-
klers must be installed in accordance
with the following instructions.
Step 1. With pipe thread sealant
applied to the pipe threads, hand
tighten the sprinkler into the sprinkler
fitting.
Step 2. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 2) or
W-Type 7 Sprinkler Wrench (Ref. Figure
3). With reference to Figure 1, the
W-Type 6 or W-Type 7 Sprinkler Wrench
is to be applied to the wrench flats.
Care and
Maintenance
The Series TY-B Sprinklers must be
maintained and serviced in accordance
with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shut down the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. Refer to the Instal-
lation section for additional information.
The owner is responsible for the inspec-
tion, testing, and maintenance of their
fire protection system and devices in
compliance with this document, as well
as with the applicable standards of the
NATIONAL FIRE PROTECTION ASSO-
CIATION (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
It is recommended that automatic
sprinkler systems be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
*
*
****
*
*
SHOWN
PENDENT
SHOWN
PENDENT
CROSS SECTION
SHOWN UPRIGHT
CROSS SECTION
SHOWN UPRIGHT
2
4
5
6
1
33
1
2
5
4
6
1
2
Bulb
Button
Frame
-
-4-
3-
5-
Deector6 -
Components:
56 mm
57 mm
38 mm38 mm
11 mm
NOMINAL
MAKE-IN
** Pipe thread connections per
ISO 7-1 can be provided on
special request.
Temperature rating is
indicated on Deector
or adjacent to orice
seat on Frame.
WRENCH
FLATS
WRENCH
FLATS
Sealing
Assembly
Compression
Screw
1/2"
NPT
3/4"
NPT
13 mm
NOMINAL
MAKE-IN
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 1
SPECIAL RESPONSE SERIES TY-B CONVENTIONAL SPRINKLERS
FIGURE 2
W-T Y PE 6
SPRINKLER WRENCH
FIGURE 3
W-T Y PE 7
SPRINKLER WRENCH
TFP663
Page 3 of 4
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assembly
Specify: (Specify SIN), Series Special
Response TY-B Conventional Sprinkler,
(specify) K-factor, (specify) temperature
rating, (specify) finish, P/N (specify from
Table A)
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
* Eastern Hemisphere sales only
P/N 57 - XXX - X - XXX
SIN
473 80K CONVENTIONAL (1/2 in. NPT) TY3641
493 115K CONVENTIONAL (3/4 in. NPT) T Y46 41
SPRINKLER
FINISH
1NATURAL BRASS
3PURE WHITE (RAL9010)*
POLYESTER
4SIGNAL WHITE (RAL9003)
POLYESTER
9CHROME PLATED
TEMPERATURE
RATING
135 57°C
155 68°C
175 79°C
200 93°C
286 141°C
TABLE A
SERIES TY-B SPECIAL RESPONSE CONVENTIONAL SPRINKLERS
PART NUMBER SELECTION
TFP663
Page 4 of 4
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a registered trademark of DuPont
1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700
© 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

Other manuals for tyco TY-B Series

5

This manual suits for next models

2

Other Johnson Controls Irrigation System manuals

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls tyco DS-1 Series User manual

Johnson Controls

Johnson Controls tyco DS-1 Series User manual

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls tyco TY720 User manual

Johnson Controls

Johnson Controls tyco TY720 User manual

Johnson Controls tyco AQUAMIST ULF AM15 User manual

Johnson Controls

Johnson Controls tyco AQUAMIST ULF AM15 User manual

Johnson Controls tyco LD User manual

Johnson Controls

Johnson Controls tyco LD User manual

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls

Johnson Controls tyco TY-FRB Series User manual

Johnson Controls tyco TY-B Series User manual

Johnson Controls

Johnson Controls tyco TY-B Series User manual

Johnson Controls tyco CC3 User manual

Johnson Controls

Johnson Controls tyco CC3 User manual

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls

Johnson Controls tyco AQUAMIST IFP User manual

Johnson Controls tyco CWS User manual

Johnson Controls

Johnson Controls tyco CWS User manual

Johnson Controls tyco DS-1 Series User manual

Johnson Controls

Johnson Controls tyco DS-1 Series User manual

Johnson Controls tyco DSB-2 User manual

Johnson Controls

Johnson Controls tyco DSB-2 User manual

Johnson Controls tyco ESFR-17 User manual

Johnson Controls

Johnson Controls tyco ESFR-17 User manual

Johnson Controls Tyco EC-11 Series User manual

Johnson Controls

Johnson Controls Tyco EC-11 Series User manual

Johnson Controls tyco AQUAMIST ULF AM28 User manual

Johnson Controls

Johnson Controls tyco AQUAMIST ULF AM28 User manual

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls

Johnson Controls tyco TY-FRL Series User manual

Johnson Controls tyco RAPID RESPONSE LFII Series User manual

Johnson Controls

Johnson Controls tyco RAPID RESPONSE LFII Series User manual

Johnson Controls Tyco TY3201 User manual

Johnson Controls

Johnson Controls Tyco TY3201 User manual

Johnson Controls Tyco EC-8 Series User manual

Johnson Controls

Johnson Controls Tyco EC-8 Series User manual

Johnson Controls tyco CHEC User manual

Johnson Controls

Johnson Controls tyco CHEC User manual

Johnson Controls tyco RFII User manual

Johnson Controls

Johnson Controls tyco RFII User manual

Johnson Controls tyco TY-B Series User manual

Johnson Controls

Johnson Controls tyco TY-B Series User manual

Popular Irrigation System manuals by other brands

Task Force Tips FM Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Task Force Tips

Task Force Tips FM Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Triad DamSurge Valve Operator's manual

Triad

Triad DamSurge Valve Operator's manual

Tyco Ultra K17 quick start guide

Tyco

Tyco Ultra K17 quick start guide

TriangleTube WASTEFLOW Installation & maintenance manual

TriangleTube

TriangleTube WASTEFLOW Installation & maintenance manual

Victaulic VicFlex I-VICFLEX.AQC-U installation instructions

Victaulic

Victaulic VicFlex I-VICFLEX.AQC-U installation instructions

G-Tools G-kit Bonanza 1m2 manual

G-Tools

G-Tools G-kit Bonanza 1m2 manual

Viking MICROMATIC VK134 manual

Viking

Viking MICROMATIC VK134 manual

Cellfast LUX IDEAL 52-160 user manual

Cellfast

Cellfast LUX IDEAL 52-160 user manual

Toro 2001 Series installation instructions

Toro

Toro 2001 Series installation instructions

Orbit 61014 instruction manual

Orbit

Orbit 61014 instruction manual

Gardigo 60085 instruction manual

Gardigo

Gardigo 60085 instruction manual

Eden WTX-500 Service manual

Eden

Eden WTX-500 Service manual

Reliable RFC56 manual

Reliable

Reliable RFC56 manual

Reliable G5 Series manual

Reliable

Reliable G5 Series manual

Autopot easy2grow 48 Set-up guidelines

Autopot

Autopot easy2grow 48 Set-up guidelines

Lindsay GROWSMART installation manual

Lindsay

Lindsay GROWSMART installation manual

Tyco Rapidresponse LFII Series manual

Tyco

Tyco Rapidresponse LFII Series manual

Reliable F3-56 Series instruction manual

Reliable

Reliable F3-56 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.