INSTALLATI N
This hood is designed for installation over a cooking appliance fitted into a penins lar or
island kitchen cabinet. The hood can be fastened to the ceiling or to a wooden b ttress,
sing the s bstantial ceiling fixing system s pplied, which is f lly adj stable in height.
The hood can be sed in either extraction mode (d cted to the o tside) or in recirc lation
mode (internal recycling).
Safety warnings
• Due to the difficulties which could be experienced when installing this hood, because
of the specific weight of the product, installation should only be carried out by a
qualified or competent technician, in compliance with all the rules concerning the
evacuation of contaminated air. The manufacturer declines all responsibility for any
damage or injury caused as a result of incorrect installation, poor workmanship or
failure to comply with the instructions provided in this manual.
• Do not connect the hood ducting to central heating flues, chimneys, etc..
• The minimum safety distance between the cooker top and the hood is 65 cm.
• Never do flambé cooking under the hood.
• Never leave frying pans unattended during use: overheated fats and oils may ignite.
• If the room in which the hood is to be used contains other non-electric appliances
(such as gas appliances), ensure that there is an adequate supply of air into the room.
When the hood is used in conjunction with other non-electric appliances the negative
pressure in the room must not exceed 0.04 mbar, to prevent fumes from being drawn
back into the room by the hood itself.
Components
The hood is made p of the following components (fig. 1):
• n. 1 hood canopy C, complete with controls, worktop ill mination and fan nit
• n. 1 telescopic frame, comprising:
n. 1 pper frame section TS
n. 1 lower frame section TI
• n. 1 telescopic chimney stack, comprising:
n. 1 pper chimney stack S
n. 1 lower chimney stack I
• n. 2 venting grilles G
• n. 2 clamps F
• n. 1 recirc lation spigot R
• n. 2 additional recirc lation spigots P1
• n. 1 bag with screws for fixing the frame to the ceiling-b ttress 1
• n. 1 bag with screws for fixing the chimney stack to the hood canopy 2
• n. 1 bag with screws for fixing the connection box 3
• n. 1 bag containing doc ments.
Instructions for installation
To facilitate installation, proceed in the order indicated below:
• Installing the Frame.
• D cting or recirc lation fitting.
• Connection to the mains power s pply.
15GB
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
• Fitting the telescopic chimney.
• Electrical connection and testing.
• Fitting the hood canopy
Installing the Frame
The frame is s itable for fixing to the ceiling or to a
wooden b ttress of s itable thickness, which m st
be firmly anchored to the ceiling or to other bearing
str ct res.
• Using a pl mb line or similar tool, identify and mark
the centre on the ceiling or b ttress, starting from the
centre of the cooking appliance.
• Use the cardboard template provided to mark the
ceiling or wooden b ttress, making s re that the
centres coincide and lining p one of the two axes (A
or B) of the template so that it is parallel with the long
side of the cooking appliance.
• Mark the position of the 4 fixing holes indicated on the
drilling template.
• Drill the holes as follows:
- Ceiling: 4 holes Ø 10 mm to fix the frame in position;
- B ttress: 4 holes Ø 8 mm to fix the frame in position.
Fixing to the Ceiling
Attention: D e to the many differing types of ceiling
constr ction, the choice of fixings is left to the
discretion of the installer. It is necessary to emphasise
that the fitting has to be absol tely acc rate beca se
of the weight of the cooker hood and beca se of the flexing ca sed by accidental lateral
stresses on the appliance. Only the following types of ceiling are s itable for installing
the Island cooker hood:
• Solid concrete ceiling: se dowels for concrete, not s pplied.
• Solid wooden b ttress ceiling: se Ø 10 mm wood screws with a minim m length of 120
mm, not s pplied.
• Cavity ceiling with inner space, having a wall thickness of abo t 20 mm; se, in this case
only, the 4 dowels and screws s pplied in bag (1). Once fixed, make s re that the base
is absol tely stable, even when the metal frame is s bjected to lateral stress. In all other
cases, if the ceiling is not strong eno gh in the area where the hood is to be fixed, the
installer m st strengthen the area sing s itable plates and co nterplates anchored to
resistant str ct res.
Fixing to the Wooden Buttress
• Connect the base of the frame to the beam sing the 4 screws size 5.2x70 with n ts and
washers, provided in bag (1)
TS
TI
4324665 01 - 001201
16
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
GB
Ducting or recirculation fitting
• Ducting fitting
• The hood can be d cted to the o tside sing either rigid or flexible d cting Ø 150 mm,
the choice of which is left to the installer (fig.3).
• If the hood is s pplied with the activated charcoal filters fitted, the filters sho ld be removed
(see paragraph on Maintenance).
• Recirculation fitting
• The filtered air is ret rned to the room thro gh the two plastic side grills G on the pper
chimney element S .
• Connect the pipe T to the ro nd fan o tlet, p shing it downwards, and fit spigot R in a
similar manner (make s re that the two additional side recirc lation spigots P1 are fitted
to spigot R). Make s re that the height of the assembly R + T corresponds to the height
of the chimney o tlet (fig.4).
• Fit the activated charcoal filters inside the canopy (see paragraph on Maintenance ). Do
not fit the venting grilles ntil after the chimney has been installed.
Connection to the mains power supply
• Check that the mains voltage corresponds to the one indicated on the rating plate
inside the hood.
• Connect the hood to the mains, inserting a two-pole switch with contact aperture of
at least 3 mm.
• Ensure that the domestic electric system is properly earthed.
• The mains lead should be routed through the central keyhole in the frame before being
connected.
• Connect the mains lead to the power supply.
Fitting the telescopic chimney
• Fit the pper chimney stack S to the frame fastened to the ceiling or to the wooden
b ttress.
• Fasten the pper chimney stack sing two of the screws size 2.9x9.5 provided in bag (2),
making s re that yo insert one screw on each side of the chimney.
• Fit the lower chimney stack I in a similar way, sing two of the screws size 2.9x9.5
provided in bag (2), inserting the chimney stack into the same slot sed for pper chimney
stack S.
•Warning: the top chimney is fitted with side o tlets. If the hood is installed in the d cting
version, the chimney m st be fitted with the o tlets facing downwards, so that they are
not visible, and in this case it is not necessary to fit the directional grilles G. If the hood is
installed in the recirc lation version, the chimney m st be fitted with the o tlets facing
pwards, and in this case the directional grilles G m st be installed.
• Fit the two venting grilles, which snap onto the metal, into the ho sings provided, so that
the symbol points pwards and the symbol points forwards. For recirc lation
versions, also check that the venting grilles are properly inserted into clamp R (fig. 5).
Fitting the hood canopy
• Fix the hood canopy C to the telescopic frame (fig.6) sing 4 screws M6x10 provided in
bag (2).
• Remove the metal grease filters (see paragraph on Maintenance).
17GB
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Electrical connection
• Take the two parts of the connection box from the packing (3).
• Fasten the two connectors together, and insert them into the connection box. (Fig.7)
• Close the electrical connection box sing 4 screws size 2.9x12.7 provided in bag (3).
• Fasten the electrical connection box to the hood canopy s pport sing 2 screws size
2.9x6.5 provided in bag (3).
• Replace the metal grease filters (see paragraph on Maintenance).
• Once the hood has been connected to the mains, check that the lighting, motor and
speed change are all working correctly.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
PERATI N
Safety warnings
• Before carring out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
• The grease filters and the charcoal filter should be cleaned or replaced as recommended
by the manufacturer or more frequently if the hood is used consistently over 4 hours
per day.
• When using a gas hob in connection with the cooker hood never leave the burners of
the hob uncovered while the hood is in use or when the pans have been removed.
Switch off the gas before removing the pan, or for just short periods and never leave
the hob unattended.
• Always ensure that the flame is kept at the correct intensity to prevent the flame from
licking round from the bottom of the pan; this will save energy and will avoid a
dangerous concentration of heat.
• Always ensure that the appliance is used in accordance with the manufacturer’s
instructions for the removal of contaminated air and odours during cooking.
Instruction for Use
Control panel (Fig.8)
Key T1 = T rns the lighting system on and off
Key T2 = T rns the motor on and off
Key T3 = Decreases the working speed
Key T4 = Increases the working speed
Key T5 = Intensive speed with timed stoppage. S itable to deal with maxim m
vapo r emission, this t rns off a tomatically 10 min tes after starting
operation. It can be disabled by pressing the key T5.
18
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
GB
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
MAINTENANCE
Constant maintenance g arantees proper operation and longterm reliability. Partic lar
attention sho ld be paid to the metal grease filters and,for recirc lation hoods only,to the
activated charcoal filters.The appliance is eq ipped with a system that indicates
a tomatically when it is time to carry o t maintenance operations.
Metal grease filters
• Cleaning
These filters m st be washed when LED Motor T2 starts to flash,or at the most once
every 2 months, sing a normal ho sehold detergent; their compact size also enables
them to be washed in a dishwasher.
• Replacement
Remove the filters one at a time, p shing the handle towards the rear of the hood (fig. 9).
When replacing, ens re that the handle faces o twards.
• Enabling the alarm signal
The hood is already set p to trigger an alarm indicating sat ration of the metal grease
filters,so this f nction does not need to be enabled.
• Resetting the alarm signal
To t rn the alarm signal off,proceed as follows:
•Turn off the Lights T1 and the S ction Motor T2;
•Press the Speed T4 for at least 3 seconds, ntil the Leds flash in confirmation. In any
case the sat rated filters alarm will only come into operation when the s ction motor is
t rned on.
ATTENTI N - There could be a possible fire hazard if the filters are not replaced
according to these instructions.
Active carbon filter
• peration
The activated charcoal filter is only fitted in recirc lation type hoods.It will retain odo rs
ntil it becomes sat rated.It cannot be washed or regenerated,and m st be replaced
when the Intensive Speed LED T5 starts to flash,or at least once every 4 months of
se.Attention:in recirc lation type hoods the T2 Motor LED may start to flash as well as
the Speed + T4 LED.This indicates that as well as replacing the activated charcoal filter,it
is also necessary to perform maintenance operations on the metal grease filters (see
paragraph Metal grease Filter).
• Replacing
Take off the metal grease filters (fig.9) and remove the activated charcoal filter from its
ho sing by t rning the clips provided (fig.10). Fit the new activated charcoal filter and
replace the metal grease filters.
• Enabling the alarm signal
In recirc lation type hoods the sat rated filters alarm m st be enabled as indicated below:
•Turn off the lights T1 and the S ction Motor T2;
19GB
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
•Press and hold the b tton T4 for at least 10 seconds, ntil the Leds start to flash.Note the
n mber of flashes:
• 2 flashes of the LED Activated charcoal filter sat ration alarm ENABLED
• 1 flash of the LED Activated charcoal filter sat ration alarm DISABLED
• Resetting the alarm signal
To t rn the alarm signal off, proceed as follows:
•Press the b tton T4 for at least 3 seconds, ntil the Leds flash in confirmation. In any
case the sat rated filters alarm will only come into operation when the s ction motor is
t rned on.
ATTENTI N - There could be a possible fire hazard if the filters are not replaced
according to these instructions.
Lighting
Version with halogen spotlights:
90 and 120 cm model, fo r 20W halogen spotlights.
• To replace (fig.11)
Remove the two screws fixing the metal ring, extract the spotlight from the lamp holder
by p lling gently. When replacing the spotlight, make s re that the two pins are correctly
inserted in the ho sing on the lamp holder.
Cleaning
When cleaning the hood:
- Never se a wet cloth or sponge, or r nning water.
- Never se thinners or prod cts containing alcohol, as they might damage the paintwork.
- Never se abrasive cleaning materials, in partic lar when cleaning stainless steel s rfaces.
It is recommended to use a damp cloth and mild liquid household cleaner.
F
TS
TI
S
I
C
G
P1
R
1
A
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
B
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
2
P1
R
SG
T
TS
S
TS
I
G
S
TI
34
56
T1 T2 T3 T4 T5
9
7
8
11
10

Other manuals for IKD 9600

1

Other Küppersbusch Ventilation Hood manuals

Küppersbusch IKD 12450 User manual

Küppersbusch

Küppersbusch IKD 12450 User manual

Küppersbusch ED635.1 Quick setup guide

Küppersbusch

Küppersbusch ED635.1 Quick setup guide

Küppersbusch KD935.2 Quick setup guide

Küppersbusch

Küppersbusch KD935.2 Quick setup guide

Küppersbusch EKD 10650.0E-84 User manual

Küppersbusch

Küppersbusch EKD 10650.0E-84 User manual

Küppersbusch Hood User manual

Küppersbusch

Küppersbusch Hood User manual

Küppersbusch IKD 954.1 Quick setup guide

Küppersbusch

Küppersbusch IKD 954.1 Quick setup guide

Küppersbusch KD 9450 User manual

Küppersbusch

Küppersbusch KD 9450 User manual

Küppersbusch IKD3700.0 Quick setup guide

Küppersbusch

Küppersbusch IKD3700.0 Quick setup guide

Küppersbusch EDIP 6650.0 User manual

Küppersbusch

Küppersbusch EDIP 6650.0 User manual

Küppersbusch KD.. 9700.0GE User manual

Küppersbusch

Küppersbusch KD.. 9700.0GE User manual

Küppersbusch KD 9850.0 Technical manual

Küppersbusch

Küppersbusch KD 9850.0 Technical manual

Küppersbusch EM6-EM10 Quick setup guide

Küppersbusch

Küppersbusch EM6-EM10 Quick setup guide

Küppersbusch IKD 9210.1 GE Operation manual

Küppersbusch

Küppersbusch IKD 9210.1 GE Operation manual

Küppersbusch EDD9960.OGE Technical manual

Küppersbusch

Küppersbusch EDD9960.OGE Technical manual

Küppersbusch DW9320 User manual

Küppersbusch

Küppersbusch DW9320 User manual

Küppersbusch EDIP 6550.0 Quick setup guide

Küppersbusch

Küppersbusch EDIP 6550.0 Quick setup guide

Küppersbusch EMA 950.0 Quick setup guide

Küppersbusch

Küppersbusch EMA 950.0 Quick setup guide

Küppersbusch IKD 10770.0 Technical manual

Küppersbusch

Küppersbusch IKD 10770.0 Technical manual

Küppersbusch KD 9570 OBC Operation manual

Küppersbusch

Küppersbusch KD 9570 OBC Operation manual

Küppersbusch EKD 10650 User manual

Küppersbusch

Küppersbusch EKD 10650 User manual

Küppersbusch KD 965.1 Quick setup guide

Küppersbusch

Küppersbusch KD 965.1 Quick setup guide

Küppersbusch KD 674.1 GE Quick setup guide

Küppersbusch

Küppersbusch KD 674.1 GE Quick setup guide

Küppersbusch KD 966.1 Quick setup guide

Küppersbusch

Küppersbusch KD 966.1 Quick setup guide

Küppersbusch EDIP 644.0 Quick setup guide

Küppersbusch

Küppersbusch EDIP 644.0 Quick setup guide

Popular Ventilation Hood manuals by other brands

Wind Crest VEN150E Install quick specs

Wind Crest

Wind Crest VEN150E Install quick specs

Beko BHCA 64640 B user manual

Beko

Beko BHCA 64640 B user manual

Vallox Pureo TX 500 manual

Vallox

Vallox Pureo TX 500 manual

Broan PM250 SERIES instructions

Broan

Broan PM250 SERIES instructions

Gaggenau AC 250 instruction manual

Gaggenau

Gaggenau AC 250 instruction manual

Swegon WISE Paragon Wall 800 Instructions for use

Swegon

Swegon WISE Paragon Wall 800 Instructions for use

Furrion FHO24R11-SS user manual

Furrion

Furrion FHO24R11-SS user manual

Midea MH90A3200W-ES instruction manual

Midea

Midea MH90A3200W-ES instruction manual

Koncar CM Series User instructions

Koncar

Koncar CM Series User instructions

castorama 3663602490272 manual

castorama

castorama 3663602490272 manual

Venmar Bistro VBLDN1 Series Installation use and care manual

Venmar

Venmar Bistro VBLDN1 Series Installation use and care manual

Broan BCSEK Series Installation use and care manual

Broan

Broan BCSEK Series Installation use and care manual

FALMEC Laguna pannellabile Instruction booklet

FALMEC

FALMEC Laguna pannellabile Instruction booklet

Smeg SB900ELITE Instructions for use

Smeg

Smeg SB900ELITE Instructions for use

Zanussi ZHC 95 ALU Instruction booklet

Zanussi

Zanussi ZHC 95 ALU Instruction booklet

ROBLIN ARIA 520 Notice

ROBLIN

ROBLIN ARIA 520 Notice

Pelgrim LSK 945 manual

Pelgrim

Pelgrim LSK 945 manual

Electrolux ECS6181G user manual

Electrolux

Electrolux ECS6181G user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.