Model PR18-1.2A PR18-3A PR18-5A
Output voltage (continuously variable, with coarse and fine adjustments)
0to 18V
Output current (continuously variable) 0 to 1.2A 0 to 3A 0 to 5A
Voltage regulation characteristics
Line regulation (with respect to ±10% variation in AC) 0.01%+2mV(3.8mV)
Load regulation (with respect to change from 0 to 100%) 0.01%+2mV(3.8mV) 0.01%+3mV(4.8mV)
Ripple/noise (10Hz to 1MHz) 0.5mVrms
Ripple peak (p-p) 2mVp-p
Transient response (output current : 5%to 100%) 100μs Typ
Temperature coefficient 150ppm/℃Typ
Current regulation characteristics
Line regulation (with respect to ±10% variation in AC) 2mA
Load regulation (with respect to change from 0 to 100%) 10mA 15mA
Ripple/noise (10Hz to 1MHz) 2.4mArms 6.0mArms 10mArms
Ripple peak (p-p) 3.6mAp-p 12mAp-p 15mAp-p
Temperature coefficient 500ppm/°C Typ
Meter
Voltmeter (2.5 % f.s.) 18V
Ammeter (2.5 % f.s.) 1.2A 3A 5A
Functions
Series operation (independent control) Series operation (with in groundable voltage limits)
Parallel operation (master-slave) Single-control parallel operation (only for power supplies of the same model)
Output
Polarity Positive or negative side groundable
Terminal color +(red), −(white), and GND (black)
Groundable voltage limit ±250V DC
Operating environment
Temperature/humidity for characteristics in spec. 0 to 40℃, 10 to 85%RH
Cooling system Natural draft
Power consumption VA/W (100V AC, ±20%) Approx. 60VA/45W Approx. 125VA/100W Approx. 200VA/165W
Power requirement 100V±10%AC, 50/60Hz, 120V/220V/240V±10%(max. 250V AC)
Case dimensions (W×H×D) mm 104×147×186 104×147×224 138×147×239
Maximum dimensions (W×H×D) mm 108×161×200 108×167×265 142×167×290
Weight Approx. 3.8kg Approx. 5.3kg Approx. 7.0kg
Accessories Instruction manual×1
REGULATED DC POWER SUPPLIES
82
Model A B C D E Size
PR18-1.2A 104 161 − 108 200 S
PR18-3A 104 167 8 108 265 M
PR18-5A 138 167 8 142 290 L
PR36-1.2A 104 161 − 108 200 S
PR36-3A 138 167 8 142 290 L
PR70-1A 104 167 8 108 265 M
PR250-0.42A 138 167 8 142 290 L
■Casedimensions(Unit:mm)