Note
2
Upon
turning
onthepowerswitch,ifthe
VARIABLE
KEY
®
is
keptpressed
until
thedisplayedvalueofeachofthevolt-
meterandammeterbecomes"0000",thesettingsofthepanel
willreturntothesaidinitialsettings,andthedatastoredin
the
PRESETKEYs
becleared.
[Caution]: Ifthesystemisturnedoffwhilethedata'0000'
is
displayedonthedisplaypannel.Thecontentofthebackup
memorymaybedestroyed.Itmay
cause
anerror.Keepitin
mind.Ifthesystemisturnedoffduetooperationalerrorsor
some
otherunavoidableerrors(forexample,powerfailure),per-
form
theoperationsdiscussedinNote2 on.Thesystemwill
beinitialized.
SettingbytheRotaryEncoder
*
Every
setvaluecanbevariedbyusingtheV/Avalueset-
ting
knoboftherotaryencodingsystem.Thesetvaluein-
creases
iftheknobisturnedclockwise.Thesetvalue
decreases
iftheknobisturnedcounterclockwise.
*WhenadjustingsettingsusingtheRotaryEncoder,the
amountbywhichthetargetparameterchangesperincre-
mentof
rotation
willvarydependingonhowquicklythe
knobisrotated.
1)
Whenthe
VARIABLE
LEDislitupgreen
("SLOW"
mode)andtheRotaryEncoderknobisrotatedslow-
ly,thevoltage,current,settingswillchangeinincre-
mentsof10mV,10mA,respectively,perclickofthe
knob.Iftheknobisturnedquickly,thesettingswill
change
inincrementsofabout2 V,2 A,respectively
(about2 V,1 A,respectively,forthe36-1model).
2)
Whenthe
VARIABLE
LEDislituporange
("FAST"
'mode)andtheRotaryEncoderknobisrotatedslow-
ly,thevoltage,current,anddelaytimesettingswill
change
bythesameincrementsasforthe
"SLOW"
mode
(i.e.,
10mV,10mA).However,iftheknobis
turnedquicklyinthe
"FAST"
mode,thesettingswill
change
inincrementsofaboutdoublethoseinthe
"SLOW"
mode.Beyondthese
values,
theincrements
willincreasenofurthernomatterhowquicklytheknob
is
rotated.
*Ifthepositiveornegative
output
voltagelevelissetto+
or- 50mV,thisnewvaluewillbestabilizedina fewse-
conds.
Thesametemporaryvalueissetwhena newvalue
is
setusingthe
PRESET
feature.
*Oneclickontherotaryencodermayforce
2-digit
voltage
andcurrentdisplaydatatochangeatthesametimeorto
remainuncharged.
*If'automaticrangeup'modeisactivatedonthe
PWR36-1
product,thedisplaydatawillbechangedin100mV
unit
each
10clicksontherotaryencoder.Notethatthedata
exceeding
20V isnotdisplayedin10mV
unit.
The
output
level
canchangein10mV
unit.
If'automaticrangedown'modeisactivated,thedataex-
ceeding19.9V isdisplayedin100mV
unit
(10
clicks).
The
databelow19.9mVisdisplayedin10mV
unit
(oneclick)
such
as19.9V^19.89V-^19.88V.
When
turning
theRotaryEncoder,donotapplyanex-
cessive
forcetoitsshaft,asthismay
cause
damage.
The
Rotaryencoderisequipped
with
a mechanicalcon-
tactandextendeduserequiresthecurrentrotaryencoder
tobereplaced
with
a newone.
Call
thelocalservicerepresentativeifthisoccurs.
11