Kisae Abso Charger 12V 100A User manual

Abso Charger
12V 100A (AC12100)
24V 50A (AC2450)
Owner’s Manual

Page 2

Page 3
For safe and optimum performance, the KISAE Abso Charger must be used properly. Carefully read and
follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING
statements.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE
Technology assumes no responsibility for errors or omissions. Note as well that specifications and
product functionality may change without notice.
Important
Please be sure to read and save the entire manual before using your KISAE Abso Charger. Misuse
may result in damage to the unit and/or cause harm or serious injury.
Product Numbers
AC12100 Abso Charger 12V 100A
AC2450 Abso Charger 24V 50A
Document Part Number
MU AC12100 Rev A
Service Contact Information
Email:info@kisaetechnology.com
Phone : 1 877 897-5778
Web :www.kisaepower.com
WARNING: This product can expose you to chemicals, including Di (2-ethylhexyl) phthalate (DEHP) which is
known to the State of California to cause cancer, birth defects or other reproductive harm. For more information,
go to www.p65warnings.ca.gov
ADVERTENCIA Este producto puede exponerlo a productos químicos, incluidos Di (2-etilhexil) ftalato (DEHP)
que el estado de California sabe que causa cáncer, defectos de nacimiento u otros daños reproductivos. Para
obtener más información, vaya a www.p65warnings.ca.gov

Page 4
Table of Contents
1. INTRODUCTION .................................................................................................4
2. PRODUCT DESCRIPTION ................................................................................7
3. UNDERSTANDING THE UNIT...........................................................................7
4. INSTALLING THE CHARGER .........................................................................10
5. UNIT OPERATION ............................................................................................13
6. SPECIFICATIONS.............................................................................................19
7. WARRANTY ......................................................................................................20
Appendix A1 (GEL, Flooded, AGM Setting CH1, CH2/CH3)
Appendix A2.1 (Lithium Setting CH1)
Appendix A2.2 (Lithium Setting CH2/3)
Appendix A3.1 (Program Setting CH1)
Appendix A3.1 (Program Setting CH2/3)
Appendix B (CH1, CH2, CH3 Charging)

Page 5
IMPORTANT SAFETY INFORMATION
This section contains important safety information for the KISAE Abso Charger. Each time, before
using the unit, READ ALL instructions and cautionary markings on or provided with the unit, and all
appropriate sections of this guide. The KISAE Abso Charger contains no user-serviceable parts.
See Warranty section for how to handle product issues.
WARNING: Fire and/or Chemical Burn Hazard!
Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.
WARNING: Failure to follow these instructions can result in death or serious injury. Keep away
from children!
•When working with electrical equipment or lead acid batteries, have someone nearby in case of an
emergency.
•Study and follow all the battery manufacturer’s specific precautions when installing, using and
servicing the battery connected to the charger.
•Wear eye protection and gloves.
•Avoid touching your eyes while using this unit.
•Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this
occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical
attention.
•Batteries produce explosive gasses. DO NOT smoke or have an open spark or fire near the system.
•Keep the unit away from moist or damp areas. Never expose the unit to snow, water etc.
•Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit
which goes through the battery or another electrical tool that may create an explosion.
WARNING: Explosion hazard!
•Do not use the unit in the vicinity of flammable fumes or gasses (such as propane tanks or large
engines).
•Avoid covering the ventilation openings. Always operate the unit in an open area.
•Prolonged contact with high heat or freezing temperatures will decrease the working life of the unit.
CAUTION:
•This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
•Children should be supervised to ensure that they do not play with the appliance.
•Do not charge non-rechargeable batteries because of the danger of eruption.
•During charging, the batteries have to be placed in a ventilated area.
•The battery terminal not connected to the chassis has to be connected first.
•The other connection is to be made to the chassis, remote from the battery and fuel line. The battery
charger is then to be connected to the supply mains.
•After charging, disconnect the battery charger from the supply mains. Then remove the chassis
connection and then the battery connection.
•Only allow children at least 8 years old to use the battery charger. Give sufficient instruction so that
the child is able to use the battery charger in a safe way and explain that it is not a toy and must not
be played with.
•The child does not try to charge non-rechargeable batteries because of the danger of eruption.
•Examine the battery charger regularly for damage, especially the cord, plug, and enclosure. If the
battery charger is damaged, it must not be used until it has been repaired.

Page 6
FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules and comply with the CE EMC Standard. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.
This equipment can generate, use, and radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
LIMITATIONS ON USE
Do not use in connection with life support systems or other medical equipment or devices.

Page 7
1. INTRODUCTION
Thank you for purchasing the KISAE Abso Charger. With our state of the art, easy to use design, this
product will offer you reliable service by providing a multi-stage multi-bank battery charger to charge
different types of batteries you have installed in your boat, RV, vehicle, or your cabin battery bank.
An innovative feature we offer is the ability to charge your main battery bank as first priority so that you
may charge this main bank quickly. Another unique feature is our silent mode setting that reduces the
charging current at night, thereby reducing the fan noise.
This manual will explain how to use this unit safely and effectively. Please read and follow these
instructions and precautions carefully.
2. PRODUCT DESCRIPTION
The Abso Charger includes the items listed below.
•Base unit
Series
Model No.
Rating
12V Model
AC12100
12V, 100A
24V Model
AC2450
24V, 50A
•Owner’s manual.
3. UNDERSTANDING THE UNIT
The Abso Charger is a fully automatic negative grounding multistage battery charger with the ability
to charge 3 separate battery banks. When first connected to an AC power source, the charger will
check all three battery banks before charging commences. The charger operates on an isolated
charging design where Battery Bank 1 is separate from Battery Bank 2 and 3. Battery Bank 1 is the
priority battery bank in the charging sequence and is recommended to be connected to the main (or
primary house) battery bank. Battery Bank 1 can be programmed with a different charge algorithm
from Bank 2 and 3 (including different battery chemistries like GEL, Flooded, AGM, Lithium or
Program battery type and different charging current). Battery Bank 2 and 3 can also be programmed
identically to Bank 1 or to any other type that is available on the setting list.
The Battery Banks 2 and 3 are always connected in parallel internally (with a separation diode) and
share a common charge algorithm.
During normal operation, the charger will do a full charge cycle to float stage on Battery Bank 1. Once
the float stage is reached, the charger starts charging Battery Banks 2 and 3 together with a bulk and
absorption mode. On completion, all the three battery banks move to float stage with a shared battery
voltage determined by Battery Bank 1 float voltage settings.
The Abso Charger also come with a unique feature that when the battery charging sequence starts,
if it senses either Battery Bank 2 or 3 have battery connected andthe battery voltage is below 11V on
12V model (AC12100)or below 22V on 24V model (AC2450), it will cycle to charge Bank 1 for 15
minutes then Bank 2 and 3 together for 15 minutes and cycle. When the charger senses both Bank 2
and 3 reach 13V on 12V model (AC12100)or 26V on 24V model (AC2450), it will then concentrate
on charging Bank 1 until it reaches the float stage. After, it will then concentrate on recharging Bank
2 and 3 (together) to float stage. On completion, all three battery banks move to float stage with a
shared battery voltage determined by Battery Bank 1 float voltage settings.
During the float stage each battery bank is isolated by an internal separation diode.
There is another unique feature Silent Mode whereby the charger has the ability to reduce fan speed
at night or whenever required. This setting can be manually turned ON and OFF through the display
and remains active for a period of 12 hours.
The charger also has the ability to awaken on over discharged Lithium battery with output terminated
by the internal BMS circuitry. This manual activation function will awaken a lithium battery that has
shut down due to under-voltage.
Important Note: The battery Bank 1 on the charger should only be connected to the main battery
bank for first priority charging and the battery Banks 2 and 3 on the charger are to be connected to
the other battery banks with lower priority (such as jump-start battery bank and/or AC generator
battery bank used in a marine application). On single bank installations, it is recommended to use
Bank 1 on the charger

Page 8
Typical wiring block diagram of the Battery Charger with 3 battery banks
•AC Source:
The charger accepts full universal input voltage (90-265Vac, 47-63Hz).
•Branch Breaker:
For use on 120V AC Input source,use a 15A branchbreaker to connect betweenthe AC Source
and the charger AC Input hardwire cable (Hot–black wire, Neutral–white wire, Ground–green
wire).
For use on 230V AC Input source, a minimum of 8A branch breaker is required from the AC
Input Source.
•Battery Bank 1, 2 & 3:
There are a total of three channels (CH1, CH2, CH3) available for charging three battery
banks (Battery Bank 1, Battery Bank 2, Battery Bank 3).
•Chassis Ground:
The unit chassis has to be grounded properly to the common ground point on the system.
•Digital Remote (optional):
The Display Remote (Part Number: ACRM1202) sold separately is used to provide unit
information from the charger. It is used as a secondary display to provide charger information.
This can also be used as a main display or controller to connect two AC Chargers of the
same model running in parallel.
•Battery Temperature Sensor –BTS (optional):
The Battery Temperature Sensor BTS (Part Number: BTS-10K) sold separately is designed
to use on Battery Bank 1 (CH1) for better battery charging performance. The sensor is also
used to terminate the battery charging process when it senses the battery temperature is
either too high or too low and is not suitable for charging.

Page 9
Understanding the Multi-Stage Charging Process:
The charger is a fully automatic “set-and-forget” design. It is designed to quickly and accurately
recharge deep cycle batteries utilizing charger algorithms that helpto maximize the life of specialized
deep cycle batteries.
The charger features a multistage smart charging technology that enables the charger to be
connected to the battery banks permanently.
As dictated by battery manufacturer’s recommendations, deep cycle batteries require a multi-stage
charge sequence for perfect, fast and accurate charging. This charger delivers four primary charge
stages (Bulk Charge, Absorption Charge, Float, and Maintenance).
Typical charging profile of the charger
•Bulk Charge ‘bUL’: The battery is charged at a full rated output current of the charger until the
battery reaches the final charging voltage, known as its absorption voltage. In this step, around
80% of the battery is recovered as fast as possible. During theBulk charge stage, an 8-hour timer
is started when the battery voltage reaches approximately 13.5V. This timer is set to avoid battery
overcharging. The charger will override the Absorption to Float stage condition and goes to Float
stage when it times out.
•Absorption Charge ‘AbS’: With the charger voltage held steady, the remaining 20% is replaced
with the charger allowing the current to drop as the battery approaches its full charge. There is a
4 hour time limit on Absorption stage to avoid battery overcharging. The timer will override the
Absorption to Float stage condition and goes to Float stage when it times out.
•Float Stage ‘FLo’: Finally, inthe float stage, the charger voltage islowered and held at a constant
and safe predetermined level. This prevents the battery from being overcharged, yet allows the
charger to supply enough current to make up for the self-discharge losses of the battery while
supporting any additional loads connected to the battery (such as DC lighting and refrigerators).
This stage allows the charger to be used as a DC power supply.
•Maintenance: This is a regular timed recharge (or return to the bulk stage). The charger switches
from float stage to bulk charge after 7 days of constant operation to ensure the battery banks
remain active.

Page 10
4. INSTALLING THE CHARGER
WARNING: It is recommended that all wiring be done by a certified technician or electrician to ensure
adherence to the applicable electrical safety wiring regulations and installation codes. Failure to follow
these instructions can damage the unit and could also result in personal injury or loss of life.
CAUTION: Before beginning your unit Installation, please consider the following:
•The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture/water,
or conductive contaminants.
•When placing the unit, allow a minimum of three inches of space around the unit for optimal
ventilation.
Mounting the Charger:
•Choose an appropriate mounting location.
•For installing in an indoor location, the unit can be mounted in any direction.
•For installations in a boat or marine environment, the unit can be mounted horizontally and vertically
(AC and DC panel facing downwards) only.
•Use the mounting template on the right to mark the positions of the mounting screws.
•Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting
surface. See mounting location as below.
Note: The charger is designed to be permanently mounted.
Chassis Grounding Connection:
DANGER: The unit chassis has to be grounded properly. Never operate the Charger without proper
grounding. Failure to do so will result in death or serious injury. The ground connection to the charger
must comply with all local and application-specific codes and ordinances.
Connect the unit’s chassis ground to the common ground point through the ground stud located near
one of the unit’s mounting slots.
DC Output Wiring:
WARNING: The DC wiring used must be of appropriate size. An individual over-current protection
device usually within 7 inches (17.8cm) of each battery bank is required. A DC disconnect switch is
also recommended.Both devices must be rated for DC voltage and current and be rated to withstand
the short circuit current available from the connected battery bank. Both devices must match with
the size of the DC wiring.

Page 11
Recommended Cable Length, Cable Size and Required Fuse Size:
Wire Length
Wire Size (AWG/mm2) - Fuse Size (A)
AC12100
AC2450
5’(1.5 m)
#2 / 12mm2
125A
#6 / 16mm2
80A
7.5’(2.2m)
#1/0 / 16mm2
#4 / 25mm2
10’(3m)
#2/0 / 35mm2
#1 / 50mm2
•Remove the DC compartment cover by removing the two screws located on the top surface of the
unit near the AC wiring compartment.
•Keep the connection between the battery and the charger as short as possible.
•Connect one end of the positive wire (red wire) to the Battery Bank 1 of charger positive terminal
with torque 4.0~5.0 N-m (35~45 lb-in) and the other end to the over-current protection device,
then the DC disconnect device. Do not over tighten as this may result in damage to the charger.
•Connect another wire from the DC disconnect device to the battery bank.
•For systems with multi-battery banks: Follow the same instruction as on Battery Bank 1 and
connect to Battery Bank 2 and 3 accordingly.
•Prepare the negative wire (black wire) and connect to the negative terminal of the charger.
Connect the other end of the negative wire to all the negative terminals of the battery bank(s).
•Place the DC Compartment cover back to the original position and secure the cover using the two
screws provided.
AC Input Wiring for 120V AC Input System with Hardwire Input:
WARNING: The AC wiring must be of appropriate size, and it must be protected by an appropriate
branch breaker (not provided) connected between the AC source and the charger. A three color
coded #12 AWG wire (L, N, and GND) with a rated minimum of 75°C wire and a minimum 12 inches
in length must be used.
Before connecting AC wiring, make sure the AC source is OFF.
•Remove AC compartment cover by unscrewing the two screws located at the top of the AC
compartment cover.
•Remove the top section of the AC Input wire strain relief located at the bottom of the base panel
inside the AC wiring compartment by unscrewing the two strain relief mounting screws.
•Use the provided butt-splices to extend the AC Input wires (L, N & GND) to the customer-
provided chosen AC wire.
•Feed the extended AC Input wire through the strain relief located at the bottom of the unit’s base
panel.
•Place the top section of the strain relief back to the original position and secure the AC extended
wire by using the strain relief and tightening its two provided screws.
•Connect the other end of the extended AC wire to the chosen AC branch breaker and, in turn, to
the AC power source. Please verify all the connections from the charger’s AC Live-wire (black
color) to the extended AC black one, the charger’s AC Neutral wire (white color) to the extended
AC white one, and the charger’s AC green wire to the extended AC green one.
Optional Battery Temperature Sensor (BTS) Connection:
The Battery Temperature Sensor (BTS-10K) optional accessory is a cable assembly come with
RJ12 plug on one end and a ring terminal (lug) on the other end.
For single charger operation:
•To install the temperature sensor (BTS-10K), simply connect the RJ12 plug from the Battery
Temperature Sensor (BTS) to the BTS Port on the charger.
•Connect the ring terminal (lug) from the BTS to the negative terminal of Battery Bank 1.
For parallel charger operation:
CAUTION: Use same model only, cannot be done with non-identical KISAE charger models)
•Two temperature sensors (BTS-10K) are required.
•Use the same procedure as above to install the first battery temperature sensor to the first
charger.
•Connect the RJ12 plug from the second temperature sensor to the BTS port on the second
charger.
•Connect the ring terminal (lug) to the same negative terminal of Battery Bank 1.

Page 12
Optional Remote Display Panel (ACRM1202) Connection:
For use on a single charger unit:
•Install the optional Remote Display Panel in the specific location.
•The RJ12 Cable that is required is a RJ12 6 wired Rolled Over (Rollover) type.
•Connect one end of the RJ12 cable to the Remote Port on the charger and the other end of the
cable to the COM_1 port on the Remote Display Panel. (Do not use COM_2 on this
installation).
•The Remote Display Panel is now ready for use. It is used as a secondary display to provide
charger information. This panel share the same functionality as the display on the unit.
For use with two charger units connected in parallel: (use same model only)
CAUTION: Use same model only, cannot be done with non-identical KISAE charger models).
•Use the same procedure as above to install the first unit and the Remote Display Panel.
•A second RJ12 cable is required for this installation.
•Install the second charger close to the first charger.
•Connect the second RJ12 cable between the second charger’s Remote Port to the COM_2 port
on the Remote Display Panel.
•The Remote Display Panel is now ready to use. Both charger displays will show ‘CON’
indicating thechargers areconnected in parallel. And allthe three push buttons on both chargers
are disabled.
•Before connecting the batteries to the chargers,
oConnect Battery Bank 1 CH1 of Charger_1 to connect to CH1 of Charger_2.
oConnect Battery Bank 2 CH2 of Charger_1 to connect to CH2 of Charger_2.
oConnect Battery Bank 3 CH3 of Charger_1 to connect to CH3 of Charger_2.
oThe Common Ground of both chargers has to be connected together.
Note: Damage to both chargers may occur if the above connections are not followed.
•The setting for the combined chargers is based on the original setting on Charger_1. To readjust
the combined charger setting, it has to be done through the Remote Display Panel.
Tips: During installation or unit setting, it is recommended to pre-set the desired charger setting on
Charger_1 first before connecting the second RJ12 cable to Charger_2 because once Charger_2
is connected all the three push buttons on the charger are disabled and the display will only show
‘CON’and the setting can only be adjusted by using the Remote Panel.

Page 13
5. UNIT OPERATION
Understanding the Battery Charging Current Setting:
The battery charging current rating is based on the battery size. When charging GEL, AGM and
Flooded batteries, each battery bank should meet the minimum Ah rating as shown on below chart.
If a smaller size battery bank is used, set the current rating to a lower value to match with the battery
bank size. Normally, the maximum charger current rating is based on half the battery bank capacity.
AC 12100
AC 2450
Current Setting (A)
100
60
40
20
10
50
30
20
10
5
Minimum Battery Capacity (Ah)
200
120
80
40
20
100
60
40
20
10
When charging a Lithium battery, consult the Lithium battery manufacturer for maximum allowable
charging current.
In float stage, the charger can provide a maximum float current of 60A for AC12100 and 30A for
AC2450.
Understanding the Digital Display:
•‘GEL’, ‘AGM’, ‘Flooded’, ‘Lithium’and ‘Program’icon represent different battery type settings.
•With only ‘CH1’, icon turned on, the numerical value on the display shows individual battery
information like battery voltage and charging current.
•With ‘CH2’ and ‘CH3’ icons turned on together, the numerical value on the display shows the total
charging current to both battery banks.
•During normal operation, the display shows the related channel’s battery voltage, charging current,
and charging stage (Bulk-‘bUL’, Absorption-‘AbS’) alternately.
•When all channels have reached Float/Full stage, the display starts showing ‘FUL’indicating that
all the batteries connected are fully charged.
Understanding the ‘INFO’, ‘NEXT’and ‘SET’Function Keys
Under Normal Operation (with AC Input connected):
‘INFO’: Press and hold the key for longer than 3 seconds to enter the charger setting mode and
display will show unit setting. Use ‘SET’ key to toggle the available settings. Press ‘NEXT’
key to keep and save the chosen setting (thedisplay will quickly flash 3 times to acknowledge
the setting is set). The display will then show the next menu to continue with other setting
parameters.
‘NEXT’: Press the hold the key for longer than 5 seconds to RESET the charger. Display will show
‘RST’ and it will force the charger to restart the charging cycle again starting with Bulk mode.
The charger can also be RESET by disconnecting the AC Input, waiting for 5 seconds and
reconnecting the AC Input again.
‘SET’: Press and hold the key for longer than 3 seconds to activate the Silent Mode operation and
‘Auto’ icon will show on the display to acknowledge the operation is in place. Press and hold
the ‘SET’ key for longer than 3 seconds to cancel Silent Mode operation and ‘Auto’ icon will
turn off. For details, see “Understanding and Executing the Silent Mode Function”
With No AC Input connected:
‘INFO’: Pressing and holding the key for longer than 3 seconds will temporarily turn on the display
for about 10 seconds and the display will show battery voltage for all 3 channels. This feature
is useful to know what battery banks are actually connected to the unit. If “0.6V” or “0.7V” is
read on the channel, it would mean that there is no battery connected to that battery bank.
The display will then show the charger revision number (e.g. ‘r1.0’). Please mark down the
revision number as this information may be required if you call for customer service.
Understanding the Two-Stage (Mode 2) and Three-Stage (Mode 3) Charging Functions:
Mode 3 Charging:
The Three-Stage Charging (Mode 3) has a Bulk,followed by Absorption, and then Float sequence.
During the Bulk stage, the battery accepts the maximum constant current from the charger. In the
Absorption stage, the battery voltage is held to constant voltage and the charging current will slowly
reduce. In Float/Full stage, the charger continuously produces lower constant Float voltage to fully
top up and maintain the battery in a fully charged state.
The charger will automatically restart the full charging cycle if it senses any one of the battery banks
is discharged to lower than 12.5V for 12V model, 25.0V for 24V model or after seven days in Float
stage to refresh the battery banks.

Page 14
Mode 2 Charging:
The Two-Stage mode 2 charging is similar tothe Three-Stage charging except that there is no Float
stage after the Absorption stage. The charger will terminate the battery charging after Absorption
stage.
The charger will automatically restart the full charging cycle if it senses any one of the battery banks
is discharged to lower than 12.5V for the 12V model, 25.0V for the 24V model, or after seven days
since the last Absorption stage to refresh the battery banks.
Understanding the Battery Temperature Set Functions:
For use when Battery Temperature Sensor is NOT in use:
CAUTION: RISK OF BATTERY DAMAGE. If the temperature sensor is not being used, never set
the battery temperature lower than the actual temperature. This may overcharge and damage the
batteries.
There are three manual battery temperature settings available on the unit for GEL, Flooded and
AGM batteries.
•Low temperature ‘Lo’, setting for when the battery is charging in a low temperature environment.
•Normal temperature ‘nor’, setting is for when the battery is charging at room temperature.
•High temperature ‘HI’, setting is for when the battery is charging in a high temperature
environment.
With different settings above, the battery charging voltage is adjusted as listed below.
Temperature
Setting
Recommended
for Battery
Temperature
Battery Type
Voltage adjustment from 25°C
normal setting
12 V model
24 V model
Low (Lo)
<5°C
(41°F)
GEL, Flooded
+ 0.675 V
+ 1.350 V
AGM
+ 0.525 V
+ 1.050 V
Normal (nor)
>5°C and <30°C
(>41°F and <86°F)
GEL, Flooded
0 V
0 V
AGM
0 V
0 V
High (HI)
>30°C
(86°F)
GEL, Flooded
- 0.27 V
- 0.54V
AGM
- 0.21 V
- 0.42V
For use when Battery Temperature Sensor is in use:
No setting on the unit is required, and the unit will automatically sense the Battery Temperature
Sensor when it is connected to the BTS Port and the manual battery temperature setting on the unit
will be over-ridden by having the Battery Temperature installed.
•Use with GEL, AGM, or Flooded Battery Type Setting:
The battery sensor installed on Battery Bank 1 will monitor the Battery Bank 1 battery
temperature and will make small adjustments to the battery charging voltage on CH1 for better
battery charging performance.
Battery
Temperature
Battery Charging Voltage Adjustment from 25 °C normal setting
Flooded and GEL type
AGM type
12 V Model
24 V Model
12 V Model
24 V Model
< 25 °C
+ 0.027 V /°C
+ 0.054 V / °C
+ 0.021 V /°C
+ 0.042 V /°C
25 °C
0 V
0 V
0 V
0 V
> 25 °C
- 0.027 V /°C
- 0.054 V /°C
- 0.021 V /°C
- 0.042 V /°C
The sensor is also used to terminate the battery charging process when the battery temperature
drops to below -25°C andthe charging process will resume again when battery temperature rises
to above -20°C. It will also terminate the charging process when the battery temperature rises to
above 70°C and the charging process will resume again when the battery temperature drops to
below 60°C.
•Use with Lithium or Program Setting:
The battery sensor installed on Battery Bank 1 will monitor the Battery Bank 1 battery
temperature. It is used to terminate the battery charging process when the battery temperature
drops to below 0°C. The charging process will resume again when battery temperature rises to
above 5°C. It will also terminate the charging process when the battery temperature rises to
above 60°C and the charging process will resume again when the battery temperature drops
to below 55°C.

Page 15
Understanding and Procedure to Set or View CH1 or CH2 and CH3 setting:
The following table shows the preset values of the battery charging voltage on GEL, Flooded and
AGM type and the user selectable battery voltage setting for the Lithium and Program type.
AC12100
Battery Type
Absorption
Float
Equalization
GEL
14.4 V
13.7 V
N.A.
AGM
14.7 V
13.6 V
N.A.
Flooded
14.4 V
13.3 V
15.5 V
Lithium
13.9 –14.8 V (0.1V step)
13.0 –13.9 V (0.1V step)
N.A
Program
13.8 –14.8 V (0.1V step)
13.0 –13.8 V (0.1V step)
N.A
Note 1: Manufacturing default setting on Lithium Battery/Program type is 14.4V (Abs) and 13.5V (Flo)
Note 2: All the above voltage will be double on 24V charger AC2450.
The following table shows the maximum available charging current and its related available
Absorption to Float stage current.
Model
Maximum
Current
Setting (CH1)
Absorption to Float
Stage Current
Setting (CH1)
Maximum
Current
Setting (CH2/3)
Absorption to Float
Stage Current
Setting (CH2/3)
AC 12100
* 100A
* 4A / 8A / 12A
60A
3A / 6A / 12A
60A
3A / 6A / 12A
40A
2A / 4A / 8A
40A
2A / 4A / 8A
20A
1A / 2A / 4A
20A
1A / 2A / 4A
10A
0.5A/ 1.0A/ 2.0A
AC 2430
* 50A
* 2A / 4A / 8A
50A
* 2A / 4A / 8A
30A
2A / 3A / 6A
30A
2A / 3A / 6A
20A
1A / 2A / 4A
20A
1A / 2A / 4A
10A
0.5A / 1A / 2A
10A
0.5A / 1A / 2A
Note: * Recommended setting (Factory Default Setting)
For GEL, AGM, Flooded battery type: (Appendix A1)
•Battery type (GEL, AGM, Flooded, Program)
•Maximum charging current (‘h-current’in A)
•Absorption to float stage current (‘L-current’in A)
•Charging stages (CH1 only) Mode2 –Bulk and Absorptionstage only, Mode 3 –Bulk, Absorption,
and Float stage)
•Battery temperature (CH1 only) (Low- ‘Lo’, Normal –‘nor’, High –‘hi’)
For Lithium battery type: (Appendix A2.1, A2.2)
WARNING: FIRE HAZARD! When using the Lithium mode to set the battery Charging parameters,
please consult the battery manufacturer on all voltage and current settings. Using wrong setting to
charge a Lithium battery may overcharge and damage the battery, resulting in battery explosion
and fire.
•Battery type (Lithium)
•Maximum Charging Voltage (CV-‘Abs’) (13.9-14.8V for 12V model, 27.8-29.6V for 24V model)
•Absorption to Float Voltage (‘FLo’) (13.0-13.8V for 12V model, 26.0-27.6V for 24V model)
•Maximum Charging Current (CC) (‘h-current’in A)
•Absorption to Float Current (Charge termination current) (‘L-current’in A)
•Charging stages - CH1 only (Mode 2 –Bulk and Absorption stage only, Mode 3 –Bulk,
Absorption, and Float stage)
For Program type: (Appendix A3.1, A3.2)
WARNING: FIRE HAZARD! When usingthe Program mode toset the battery charging parameters,
please consult the battery manufacturer on all voltage and current settings. Using a wrong setting
to charge the battery may overcharge and damage the battery, resulting in battery explosion and
fire.
•Battery type (Program)
•Absorption Voltage (‘Abs’) (13.9 - 14.8V for 12V model, 27.8 - 29.6V for 24V model)
•Absorption to Float Voltage (‘FLo’) (13.0 - 13.8V for 12V model, 26.0 - 27.6V for 24V model)
•Maximum Bulk Current (‘h-current’in A)
•Absorption to Float Current (‘L-current’in A)
•Charging stages - CH1 only (Mode 2 –Bulk and Absorption stage, Mode 3 –Bulk, Absorption,
and Float stage)

Page 16
Procedure to Equalize Flooded Battery:
DANGER: Explosion Hazard. The battery generates explosive gasses during equalization. Follow all
the battery safety precautions listed in the manual. When using the equalization mode, the user has
to be sure the battery connected to the channel is a flooded battery type. Equalizing a non-flooded
battery may overcharge battery and cause the battery to explode.
CAUTION: Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can be
equalized. Consult your battery manufacturer or read the battery manual when you try to equalize
your batteries.
Disconnect any DC load connected to the battery, as during equalize mode, the charger will produce
15.5V on 12V model, or 31.0V on 24V model to the batteries. The equalized voltage may damage the
DC connected tothe battery. You must monitor the battery specific gravity throughout the equalization
process to determine the end of the equalizing cycle.
Before setting the equalization mode on the specific channel, please be sure the battery connected
to the specific channel is a flooded battery type. When the battery equalization process started, the
charger will automatically fully charge the selected channel first and follows with 1 hour of 15.5V
equalization process. Consult or follow theinstruction as provided by the battery manufactureron how
to check the battery electrolyte level and or refill with distilled or deionized water during the 1 hour’s
equalization period. All cells should have similar electrolyte levels. If distilled or deionized water is
added, batteries must undergo a complete charge cycle.
The charger cannot determine when to terminate the equalization of the battery. A one-hour timeout
is set as a safety feature by requiring the user to continually re-activate it as necessary after checking
the batteries manually. During the equalization mode, the other two battery banks are disabled.
Procedure to Awaken Over Discharge Lithium Battery
Some Lithium ion batteries have BMS circuitry that turns the battery off when over discharged. The
charger may not recognize a battery is connected and start the charging process. To awaken the
Lithium battery, press and hold ‘INFO’ and ‘SET’ buttons for 5 seconds. The charger will provide
13V (with 10A current limit) to the battery terminal for 10 seconds. If battery voltage was measured
at the terminal after 10 seconds, the lithium battery is awakened, and the charger will restart the
charging process. If no voltage was measured at the terminal, the charging process will terminate.
This function works only on Lithium battery setting.

Page 17
Understanding and Executing the Silent Mode Function
A unique feature of the KISAE Abso Charger is the ability to reduce fan speed at night or whenever
required. This setting is manually activated via the Digital Display.
Mode Operation
Fan Operation
AC12100
AC2450
Normal Mode
Full Speed
100 / 60 / 40 / 20 / 10 (A)
50 / 30 / 20 / 10 / 5 (A)
Silent Mode
Low speed or Fan OFF
50 / 50 / 40 / 20 / 10 (A)
25 / 25 / 20 / 10 / 5 (A)
Tips: Use this function during nighttime or when a quiet environment is needed. Please also note
that the charging time will increase in this mode because the charging current may be derated.
This function can switch to ON or OFF at any time during the charging period.
To set this function, press and hold ‘SET’key for 5 seconds to execute the Silent Mode. The ‘Auto’
icon will show on the display. To turn this function off, press and hold the ‘SET’function for 5 seconds
to turn off Silent Mode. The ‘Auto’icon on the display will turn off and the charger current and the
fan speed will return to normal.
Note: the charger will automatically depart from Silent Mode after 12 hours from being set.
Procedure to Change CH1 to Power Supply mode
•Set CH1 to Program mode setting.
•Press and hold ‘INFO’ and ‘NEXT’ button for 5 seconds
•Display will show ‘P’ for approximately 5 seconds to indicate Power Supply mode is activated.
•The charger will supply the set Absorption voltage in Program mode with 100A current limit at
CH1 and the display will show the supplied voltage and the supplied current alternately.
•To cancel Power Supply mode, press and hold ‘NEXT’button for 3-5 seconds to reset the
charger and CH1 will return to charging the battery with Program mode.
Note: Power Supply mode can only be used on CH1 only.
Understanding the Protection Features
Derating the Charging Current: When the charger senses the environmental temperature is above
50°C, the maximum charger current will de-rate to 1/2 of the value (A02 warning code will display).
The charger will recover automatically back to the maximum charging current when the
environmental temperature drops to below 45°C.
Over Temperature Shutdown: When the charger senses the environmental temperature is above
60°C, the charger will shut down. It will recover automatically when the environmental temperature
drops to below 45°C.
Battery Reverse Polarity: When a reverse polarity is connected to the battery bank, Fault Code E03
on display will appear. In some case, the user replaceable DC fuse located near the DC Output
terminals may blow and Error code E08 will display.
AC Input VoltageProtection: The charger will shut down when itsenses the AC input voltage is outside
of the operatingrange. A faultcode will display. The charger will recoverautomatically whenitsenses
the AC input voltage has returned to the normal operation range.
Disconnecting the Battery Bank: To avoid any spark on the battery terminal, always disconnect AC
Input before removing or disconnecting the battery.
BTS Shutdown (with optional BTS in use): To avoid any battery damage especially when a Lithium
battery is used, the charging cycle will be terminated when the optional BTS senses the battery
temperature is out of the charging range.
Charging Batteries with Low Voltage
The charger is designed to charge batteries with voltages on their terminals greater than 3Vdc on 12V
model and 6Vdc on 24V model. For lower voltages, the batteries can be temporarily and partially
charged using the charger’s Power Supply mode under Program setting, before returning to the
proper battery type setting. Please noted the Power Supply setting can only be used on CH1.
Reinitiating the Charging Cycle and the battery connection status manually
The charging cycle can be reset or reinitialized at any stage. Press the hold the key for longer than 5
seconds to RESET the charger. Display will show ‘RST’ and it will force the charger to restart the
charging cycle again starting with Bulk mode. The charger can also be RESET by disconnecting the
AC Input, waiting for 5 seconds and reconnecting the AC Input again.

Page 18
Understanding the Error Codes
Error codes will be shown on the display when either an internal fault such as high internal
temperature or external fault like AC input voltage out of range is detected. The unit will shut down.
Code
Condition
Corrective Action
A01
Temperature Sensor (BTS) is defective.
Check and or replace the sensor.
E01
Unit shutdown due to low AC Input (< 85 +/- 5Vac)
Check AC input source. The unit will automatically
recover when the AC Input voltage return to
> 108 +/-5Vac
E02
Unit shutdown due to high AC Input (>270 +/- 5Vac)
Check AC input source. The unit will automatically
recover when the AC Input voltage returns to
< 260 +/-5Vac
E03
Battery is connected backwards
Check all battery connections
E04
Charger Internal temperature is too high and it has
shutdown. The unit will automatically recover when
the unit cools down.
The ventilation of the unit is blocked or the environmental
temperature is high. Reduce charging current or improve
the ventilation near the unit.
E05
Not used.
E06
For non- Lithium Battery type setting:
High battery temperature >70 °C (158°F) is sensed
by the BTS when installed. The unit will shut down.
The unit will automatically recover when the battery
temperature has reduced to 60°C (140°F).
For Lithium battery type setting:
High battery temperature >60 °C (140°F) is sensed
by the BTS when installed. The unit will shut down.
The unit will automatically recover when the battery
temperature has reduced to 55°C (131°F).
Check the battery, charger setting, and its environment.
E07
For non- Lithium Battery type setting:
Low battery temperature < -25°C (-13°F) is sensed
by the BTS when installed. The unit will shut down.
The unit will automatically recover when battery
temperature reaches
-20°C (-4°F).
For Lithium Battery type setting:
Low battery temperature < 0°C (32°F) is sensed by
the BTS when installed. The unit will shut down. The
unit will automatically recover when battery
temperature reaches 5°C (41°F).
It is not recommended to charge the battery at low
temperatures.
E08
DC Output fuses are blown.
Check battery connection and replace the fuse with the
same type and rating.
E09
Unit shutdown due to high battery voltage (> 17 Vdc
on 12V model and >34 Vdc on 24V model). The unit
will automatically recover when battery Voltage is
reduced to <16Vdc on 12V model or <32 Vdc on 24V
model.
Check battery and charger settings. Check also if there is
any other DC supply connected to the battery banks.

Page 19
6. SPECIFICATIONS
AC12100
AC2450
Charger Output:
Output Current (Maximum)
100A
50A
Output Voltage Range:
Charge
13.8 – 14.8 V
27.6 – 29.6 V
Float
13.0 - 13.8 V
26.0 – 27.6 V
Equalize (Flooded Battery)
15.5 V
31.0 V
Charging Control
Three stages (Bulk/Absorption/Float)
Two stages (Bulk/Absorption)
DC Output Bank
Three (CH1, CH2, CH3)
Selectable Battery Type
Gel, AGM, Flooded, Lithium, Program
Parasitic Current
< 2 mA
Charger Input:
AC Input Voltage (Nominal)
100, 120, 220, 230, 240 VAC
AC Input Operating Range
90 - 265 VAC
AC Input Frequency Range
47 - 63 Hz
Power Consumption (Full Load)
1750W
1750W
Power Factor Correction
Yes
Charger Efficiency
> 82%
Protection and Features:
Reverse Battery
Yes, unit shutdown
Over Charge
Yes, unit shutdown
Over Temperature
Yes, unit de-rated and shutdown
Output Short Circuit
Yes, unit shutdown
Cooling
Force air ventilation
Temperature Setting
Hot, Normal, Cold (with no sensor connected)
Battery Temperature Sensor Port
RJ12 (for use with optional Battery Temperature Sensor)
Remote Display Port
RJ12 (for use with optional Remote Display Panel ACRM1202)
Display:
LCD Display (with back lighting)
Charging status, Battery Voltage
Warning and Fault Code
A01, E01-09
AC Input and DC Output Connection:
AC Input Connection
Hardwire or AC with EU, UK, AZ plug
DC Output Connection (POS)
Heavy Duty Screw Terminal (3 banks)
DC Output Grounding (NEG)
Heavy Duty Common Ground Screw Terminal
Environmental and Operating Temperature:
Storage Range
-40° to 70° C (-40° to 158° F)
Operating Range
-20° to 60° C (-4° to 140° F)
Humidity
5-95%, RH non-condensing
Ingress Protection
IP32
Based Unit Weight and Dimensions:
Weight
12.3 lbs ( 5.6 Kg)
Dimension
9.3 x 16.7 x 4’ (236 x 425 x 102.7 mm)
Regulatory Compliance:
Standards/Safety (North America)
Approved to UL1236 including the marine supplement
UL1564
CSA C22.2 107.2-01
Standards/Safety (European Union)
CE marked for the low voltage directive 2006-95-EC
Complying with EN60335-2-29 battery chargers
Approved to IEC60529:2001, IP32 ingress protection level
Standards/EMC (North America)
Class B according to FCC part15B and ANSI C63.4
Standards/EMC (European Union)
CE marked for the EMC directive 2004-108-EC
Complying with EN55014-1, EN55014-2, EN61000-3-2, and EN61000-3-
3 (as equivalent IEC standards series)
Note: Specifications are subject to change without notice.
Accessories (optional):
Remote Display Panel ACRM1202
Battery Temperature Sensor BTS-10K

Page 20
7. WARRANTY
One Year Limited Warranty
The limited warranty program is the only one that applies to this unit, and it sets forth all the
responsibilities of KISAE. There is no other warranty, other than those described herein. Any implied
warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the
duration of this warranty.
This unit is warranted, to the original purchaser only, to be free of defects in materials and
workmanship for one year from the date of purchase without additional charge. The warranty does
not extend to subsequent purchasers or users.
The manufacturer will not be responsible for any amount of damage in excess of the retail purchase
price of the unit under any circumstances. Incidental and consequential damages are specifically
excluded from coverage under this warranty.
This unit is not intended for commercial use. This warranty does not apply to damage to units from
misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity
power sources.
RETURN/REPAIR POLICY:
If you are experiencing any problems with your unit, please contact our customer service department
at info@kisaepower.com or phone 1 877 897-5778 before returning the product to the retail store.
After speaking to a customer service representative, if products are deemed non-working or
malfunctioning, the product may be returned to the purchasing store within 30 days of original
purchase. Any defective unit that is returned to the manufacturer within 30 days of the date of
purchase will be replaced free of charge.
If such a unit is returned more than 30 days but less than one year from the purchase date, the
manufacturer will repair the unit or, at its option, replace it, free of charge. If the unit is repaired, new
or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be replaced
with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will
then be warranted under these terms for the remainder of the warranty period. The customer is
responsible for the shipping charges on all returned items.
LIMITATIONS:
This warranty does not cover accessories, such as adapters and batteries, damage or defects result
from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage
or exposure to sunlight), accidents, damage during shipping to our service facility, alterations,
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and
maintenance, fire and flood.
If your problem is not covered by his warranty, call our Customer Service Department at
info@kisaetechnology.com or 1 877 897-5778 for general information if applicable.
Service Contact Information
Email: info@kisaetechnology.com
Phone : 1-877-897-5778
www.kisaepower.com