testing. Irreparable damage will occur if this instruction is not followed.
No. 2019/2015.
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
BLED5BB / BLED5BW / BLED5SB / BLED5SW
SAFETY
•This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•Please isolate mains prior to installation or maintenance
•Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse, or circuit breaker
•Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for
installation
•This product is Class I and must be earthed
•This product is IP54 rated
INSTALLATION
Note - If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
•Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•Round cable should be used for the mains supply. The use of flat cable will cause water ingress to the
fitting
•Remove the front bezel by unscrewing the two side screws
•Remove the PCB from the back plate by unscrewing the two diagonal screws
•Using the back plate as a template, mark the location for, and drill the fixing holes ensuring not to
infringe with any gas/water pipes or electrical cables
•Feed the mains cable through the rubber grommet to retain IP rating, and secure the base plate to the
surface
•Fix the base to a suitable solid surface using the screws provided. Rubber washers or sealant should
be applied around the screw heads to prevent water ingress
•Connect the luminaire to the mains supply ensuring the correct polarity is observed: L - Live (brown), E
- Earth (green/yellow), N - Neutral (blue)
•Reattach the PCB and front bezel
•Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for direct installation in the ground, nor in a retaining wall where the ground may
become saturated behind.
This product is not suitable for installation in or near a coastal or marine environment.
GENERAL
This product contains a light source of energy efficiency class F to Regulation (EU) No. 2019/2015.
This product contains a light source and control gear which can be replaced by a professional.