These instructions should be read carefully and retained after installation by the end user for future
reference and maintenance.
These instructions should be used to aid installation of the following products:
TRIBCCW, TRIBCWW
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for
installation
• This product is Class I and requires an earth
• This product is IP20 rated
• This product is non-dimmable
• Provide power to the point of installation
• Choose a suitable location for the luminaire and provide power to the point of installation.
When drilling holes into the surface ensure that the hole does not infringe with electrical cables or
water/gas pipes
• Connect the luminaire to the mains supply via a suitable terminal connector ensuring the correct
polarity is observed (see Fig 1). Live (brown), Neutral (blue) and Earth (yellow and green)
• Switch on power supply and check for correct operation
Fig 1
TRIseries
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
TRIBCCW,TRIBCWW,TRICCW,TRICWW
SAFETY
• Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
currentIEEWiringRegulations(BS7671)
• Pleaseisolatemainspriortoinstallation/maintenance
• Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
• PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
• ThisproductisClassIandrequiresanearth
• ThisproductisIP20rated
• Thisproductisnon-dimmable
INSTALLATION
• Providepowertothepointofinstallation
• Chooseasuitablelocationfortheluminaire.Whendrillingholesintothesurfaceensurethattheholedoesnot
infringewithelectricalcablesorwater/gaspipes
• Connecttheluminairetothemainssupplyviaasuitableterminalconnectorensuringthecorrectpolarityis
observed(seeFig1).Live(brown),Neutral(blue)andEarth(yellowandgreen)
Fig1
• Switchonpowersupplyandcheckforcorrectoperation
WARNING
Thisproductmustbedisconnectedfromthecircuitifsubjectedtoanyhighvoltageorinsulationresistancetesting.
Irreparabledamagewilloccurifthisinstructionisnotfollowed.
Earth(yellow
andgreen)
2