KOCOM KDP-603 Instruction Manual

KDP-603/603A User’s Manual for Operation and Installation
Interphone
for Apartment Unit
KDP-603 O0808
This manual is based on the date as shown in the right and specifications
are subject to change without notice for quality improvement.
PRODUCT
MODEL
DATE PURCHASED
WARRANTY PERIOD
AGENCY ADDRESS
■
KOCOM Warranties the original purchaser of this product
as follows.
1) This product is producedunder strict quality control and inspection procedures.
2) If this product breaks down during proper use as a result of product defect, KOCOM
will repair it within one year from date of purchase free of charge.
3) The following cases will be subject to charge, even during warranty period:
a. Breakdown during transport, or through careless treatment, by consumer.
b. Breakdown cause by unauthorized repair, or system modification.
c. Breakdown caused by natural disaster or power disorder.
Warranty
Warranty Card
To receive after-Sale service, have the following ready
when you contact our branches
1. Name of the product
2. Model number of the product
3. The area of problem
4. Phone number and address at
which you can be contacted.
■Interactive call and communication between house and guardroom.
■Communication with lobby phone and door open function.
Thank you very much
for purchasing KOCOM
video doorphone.
please read this manual
thoroughly to ensure
correct usage, before
operating.

32
ㆍPlease, save this manual after reading these instructions carefully. ㆍRead and understand all instructions to set up rightly.
ㆍThis Cautions for Safety may include items that are not contained in specifications of the product that consumer purchases.
ㆍIf you need assistance with the set-up or operation, please contact with A/S center.
The important marks in the manual.
To help our customers to understand this manual, to prevent any personal injury or property damage, some marks are used in the manual.
The marks and the drawing signs are below. Please, understand the marks before reading the manual.
The meaning of the drawing signs.
Cautions for Safety
For safe use, please stick to the following cautions.
Caution
Warning
Sign to show what not to do Mishandling the device with ignoring this sign may result in serious injury or death.
Sign to tell you that you should follow the instructions. Sing to tell you that you need more attention including high voltages, electric shock, danger, warning)
Sign to tell you that you can’t disassemble this unit. Sign to tell you that you must unplug the unit.
Mishandling the device with ignoring this sign may result physical injury or material damage.
Cautions for set-up
Cautions for Use
Cautions for Repairs and Maintenance
ㆍDo not install this unit near the water and dust, for example, in a bathroom or near the washing machine. It caused fire and electric shock.
ㆍDo not install this unit near the fire, for example, near kitchen sink, heater or the like.
ㆍDo not install near the noxious gar such as Hydrogen Sulfide, metal power and the like.
ㆍDo not install near the water and chemicals.
ㆍDo not give any damage, break and modify the plug. Overloading, heating, pulling causes the damage.
ㆍDo not place the plug near the heater. The damaged code causes fire and electric shock. Do not pull the power code when unplugging.
ㆍThe damaged code causes fire and eclectic shock. Must pull with plug. Do not touch with wet hands. It causes the electric shock.
ㆍDo not use any other voltage, except the marked regular voltage.
ㆍDo not use the power terminal at the units to other electric device except the designed device.
ㆍDo not install the units at the leaking place if it doesn’t have any waterproof mark. Do not install the unit when the power is on.
ㆍInstall the circuit breaker after checking the safety such as electric shock and leakage. Turn off the power before you install or A/S
ㆍCheck the suitability of the lines for installing when you use the exiting lines.
ㆍDo the wiring work by using the designed material.
ㆍConnect the electric wire with the designed ways and ground.
ㆍDo not connect with any other devices except the designed devices to compose the system.
ㆍUnplug electric wire and communication lines from the units before moving to another place.
Warnings for Usage
ㆍThis unit is not designed for security purpose. ㆍDo not handle the unit with the wet hands.
ㆍDo not place a pot with water or a small metal material on the Units. ㆍDo not cover the ventilating opening or put any metal material in the units.
ㆍOpen the main gate after checking ID if the image and sound system do not work. Call A/S
ㆍDuring thunderstorms, avoid using this unit. ㆍThere may be a remote risk of an electric shock from lighting.
ㆍDo not modify the unit.
ㆍDo not disassemble the back and cabinet cover.
ㆍChange the damaged electric code.
ㆍUnplug this unit from plug socket and refer servicing to an authorized service center when the following conditions occur:
ㆍIf liquid has been spilled into the unit. ㆍIf the unit does not work normally by following the operating instructions.
ㆍIf the unit exhibits a distinct change in performance. ㆍIf the unit has been dropped or physically damaged.
ㆍThe mains plug, as a disconnection device, shall remain readily accessible by the user.
Cautions for Use
Cautions for Abnormality
ㆍDo not disassemble this unit at will as this device is composed by precision parts. ㆍInstall the unit by following the set-up instructions of Kocom.
ㆍDo not touch or insert any foreign substances, for example, sticker, magnetic, opener and the like
ㆍMake U-type at the end of wires as the rain can effect on the system by following the wires during the rainy season.
ㆍSeparate the AC/DC lines with the hook of the wall-mounted type when installing. ㆍConnect the lines after peeling the wires properly
ㆍDo not distribute signal line with AC line. ㆍUse the designed driver to connect the lines to terminal
ㆍDo not clean the LCD with the damp cloth for cleaning. Use the only dry and soft cloth. ㆍDo not install the main gate monitor at the leaking place.
ㆍThis product is designed as a home VIDEOPHONE and cannot use continuously like monitor camera.
ㆍIf there is temperature difference between inner part of camera and surrounding, dew condensation occurs on camera lens and may disturb image.
If dew condensation is removed from camera lens, image quality recovers.
ㆍWhite LED light examination range is narrower than camera shot range at night, so there is less amount of light at night than day.
So it is difficult to see the face in low illumination condition due to noise increase on screen, but it is not from defect.
ㆍMonitor screen (liquid crystal panel) is not in defect when some pixels always light or black out.
ㆍPlease install monitor and camera over 5cm away. Also, avoid installing at a place with too much noise, because too much noise around camera causes phone
call inferiority.
ㆍDo not place an object within 20cm in front of monitor. It causes phone call inferiority, especially because microphone is installed at the top of monitor.
ㆍIf strong light such as sunlight flows into camera module, screen saturation (or strange mark) and image shaking might occur.
This is not a defect, so please do not install camera where a direct ray of light do not flow if possible.
ㆍIn some cases there is occurrence of product destruction, malfunction, noise mixing and picture quality deterioration due to mixing of other tool’s induced
voltage or thunder with communication wiring of monitor/camera, monitor/extended monitor.
Do not wire with power line such as outdoor wiring or AC power, or phones and other tools.
ㆍYou cannot use it if you incorrectly wire the AC voltage between monitor/camera, monitor/extended monitor. Call the store or agency where you purchased
this product and consult to solve the problem.
Beware that unfixable damage might be caused due to authorizing AC voltage on communication wiring of monitor/camera, monitor/extended monitor.
ㆍDo not ever disjoint this product. It may cause electrocution accident when touching high-voltage circuit inside this product.
ㆍOutside power authorizing this product must be confirmed of product description and use rated voltage. Beware that if higher voltage is authorized,
unfixable damage might be caused due to product destruction.
ㆍPower must be connected to domestic voltage (product rated voltage) consent or interior wiring.
If connected to other motive power or inverter-type power, product destruction, noise mixing, and picture distortion may occur.
ㆍDo not drop this product. Glass is used for monitor and might break, or cause other circuit inferiority.
In such case, immediately turn down the power switch, and call to consult agency or store in which this product was purchased.
ㆍIf installed near transmission antenna such as broadcasting station, electric wave may mix and cause picture distortion or voice mixing.
ㆍAvoid installing near tools with strong electromagnetic waves such as microwaves and cell phones, or it may cause picture distortion.
ㆍDo not install monitor in following places.
①Above or around water heater, rice-cooker, heater ②Place exposed to direct rays of the sun ③Place with temperature below 0'C such as cold store
④Place with high humidity such as bathroom, washroom, heated room
⑤Place with a lot of gas, dust, smoke ⑥Dangerous place with sprays of water or chemicals
ㆍDo not wipe with insecticide, drugs or chemicals such as thinner and alcohol, or it may damage
the surface of this product.
ㆍBeware of occurrence of image quality deterioration or malfunction from cause of humidity due to
penetration of chemicals or water into camera’s urea resins.
ㆍAs in the picture, it prevents temperature difference of camera (outside) and monitor (inside), and
removes dew condensation caused by humidity of camera window.
ㆍCamera must be installed when wall cement is completely dry.
ㆍWhen product is installed in winter below -5'C, wait for approximately 2 hours to connect. Dew formation
in monitor and camera due to temperature difference inside and outside may cause product defect.
ㆍAvoid installing monitor and camera in place directly exposed to heat or where gas noxiousness is
highly occurring.
Safety Instructions, Warnings and Cautions of Each System
VIDEOPHONE
Things You Need to Know
Cautions
ㆍ
The law limits distributing the power lines to an authorized person from government. The work from an unaurhtorized person cause fire or electric shock.
ㆍPlace this unit securely on a stable surface. Serious damafe and/or injury may result if the unit falls.
ㆍDo not set up this unit near the leaking place because it may expose you to dangerous voltages or other risks.
ㆍEven if your product is water proof, do not install it slanted place of water leakage, which can a short circuit.
ㆍDon’t put any stuff in 30cm around the monitor, not to block the air hole.
ㆍThe work of distributing wires needs skills and experiences. So please, for assistance, contact your dealer or call service center.
ㆍ
The communication lines should be built in being distant from t
he power source. This may result in the risk of fire, electric shock and communication disorder.
ㆍSetting the communication lines in a high humid place such as outside without any protection from rain causes the communication disorder.
ㆍKeep the hook at the wall-mounted device safe. The hook may cause the physical injury.
ㆍThink about the thickness and quality of wall material. The unqualified material may make the device fall.
ㆍSet the device of the wall-mounted type not to fall. Falling from an earthquake causes personal injury.
ㆍDo not overload on the device.
ㆍ
Keep the inside of the device clean. Having the dust inside without any cleaning for a long time causes the fire. If necessary, contact your dealer or
service center to get cleaning service.
ㆍUnplug this device when you want to check the inside. If there is no plug, please, turn off the circuit breaker.
ㆍUnplug this device when you try to move it to another place. If the electric line is connected inside of the unit, please contact your dealer or service center.
ㆍDo not use liquid or aerosol cleaners. Use a damp cloth for cleaning
Stop up P.V.C. pipe using
adiabatic substances, to
prevent aircirculation
Caution

Place bracket on the wall and fix it
with screws. After wiring, fit the rear
side of main frame to a groove in the
bracket and pull the main frame down
to fix.
Product Specification
External Wiring Diagram
Precautions for Wiring
■As incorrect wiring may cause the device’s non-operation or poor communication quality, please
carefully conduct wiring work.
■When connecting a wiring chord to a terminal, loosen screw, insert the end of the chord into the bottom
part of screw, and tighten the screw.
■When fixing wiring chord, use stapler not to cause damage to the chord.
■When using existing wiring, please be cautious not to cause disconnection and short-circuit.
Power Lamp (Green)
Internal Call button
Door Open Button: Pressing the button after
communication with lobby, opener installed
lobby door is opened.
Guard/Lobby Button: Used in call to guardroom,
conversion to communication with guardroom, or
communication after call from lobby
3-Level Volume Switch
Guard/Lobby (Green)
Inner Lines (Yellow)
Instructions for Installation
Component’s Name
Keep away from humidifier
and stove. High temperature
and humidity may cause
troubles.
When cleaning, do not use wet hand,
volatile benzene or paint thinner.
Use soft cloths dipping in neutral
detergent to wash this device and dry
it with dry clothes.
As this device consists of electronic precision components, do not attempt to
disassemble.
Do not drop this device
and avoid strong impact.
Precautions for Operation
Clean the exterior of this device
with soft cloths at times to keep
it in clean state.
B
E
N
Z
E
N
E
T
H
I
N
N
E
R
45
POWER LINE : IV 1.2Ø
VOICE/DATA : IV 0.8Ø
DOOR VOICE : IV 0.65Ø
Power
Consuming
Electricity
Guaranteed
Operation
Temperature
Communication
Mechanism
Melody
Wiring
Wiring Distance
Dimensions
DC 14V~18V
KDP-603 KDP-603A
Max 1W (standby mode) /
Max 3W (operation mode)
AC220V~, 60Hz
Max 1.5W (standby mode) /
Max 5W (operation mode)
0℃~ 50℃
Balance Circuit
DUPLEX HANDSET CONVERSION
front door, inner lines, guardroom, lobby
5-line polar wiring ( VCC/GNDVoice 1/Voice 2/DATA)
( OPTION : Chime SW 2Line(signal / GND )
Power(+/GND) 1.2 Ø 300M with in
( OPTION : ChimeSW - Ø 0.5 SINGLE CABLE / with in 50m)
92(W) x 210(H) x 57(D) mm
Upgrade
terminal
When KDP-603A is used,
no.1 pin is not used.
For KDP-603A
installation
1.DC 14V~18V
2.GND
3.VOICE1
4.VOICE2
5.DATA
6.DOOR VOICE

■Inner line call to the extend in door unit
·Picking up handset and pressing (inner line) button, then,
extended in door unit is called out (call maintains for 30 seconds).
·Inner line LED is turned on.
·Extended unit responds to the call, Call maintains for 3 minutes.
(LED is turned off.)
·Hanging up handset, communication is ended.
■Inner line call from extended in door unit
·If house received a call, tone sound rings in house handset (for 30 seconds)
·(inner line) LED flickers.
·Picking up handset, communication begins (maintains for 3 minutes).
(When communication begins, LED is turned off).
·Hanging up handset, communication is ended.
Call from guardroom to house
Call to guardroom for communication
Operational Description
·Pressing chime switch to call, chime tone of call from front door rings
(device does not support communication function and only detects call state).
·Inner line call and communication ‐chime tone of inner line call rings and communication maintains
for 3 minutes (installation of additional monitors and interphones is required).
·Communication with lobby phone ‐After chime tone rings, user can communicate with lobby phone
for 3 minutes. (If pressing the door open button during the communication with lobby phone, opener
installed common lobby door is opened.)
·Call to and communication with guardroom
If pressing guard button on interphone, user can call to and communicate with guardroom.
·When a lobby calls to house in standby mode, tone sound rings for about 30 seconds in house.
·Speaker outputs tone sound and (lobby/guard) LED flickers.
·Picking up handset, communication with lobby is automatically available
(available communication time: 3 minutes) (At this time, LED is turned off.)
·To open the door during the communication wit lobby, press door open button and opener will
automatically operate.
·Hang up handset, communication is ended (call to lobby function is not available).
·If picking up handset and pressing guard/lobby button,
guardroom is called out (call maintains for 30 seconds).
(When other house is not on the line, LED is turned on.)
·If guardroom responds to the call, call state is maintained (for 3 minutes).
(When communication begins, LED is turned off.)
·If guardroom calls to house, tone sound rings in handset of house (for 30 seconds) and (guard/lobby)
LED flickers. Picking up handset, communication begins (communication maintains for 3 minutes).
·At this time, LED is turned off.
·Hanging up handset, communication is automatically ended.
■Call from lobby
·5-line polar wiring between wirings in main line of apartment unit
·6-line polar wiring between KVM-520,KIV-102,KIV-212,KCV-802R (monitor) and interphone
·2-line non-polar wiring in connection with chime switch at front door
·6-line polar wiring when installing more devices
Functional Specification
Wiring Specification
Inner line call and communication
67

Instructions for Operation
■
Instructions for Operation
Model: (KDP-100 / KLP-100 / KLP-P100 / KLP-C100), Functional Specifications
▷
Call to house
When a visitor calls to house using lobby phone, press house number.
e.g) In case of calling to house No.101
> Pressing call button, call sound rings and house is called.
> If the house responds to the call, communication is available for 3 minutes.
(Pressing door open button during the communication, opener installed with common gate is opened.)
> When communication is ended, device returns to standby mode.
▷
Call from lobby phone to guardroom
Pressing“0”and call button on the lobby phone, guardroom is called and lobby phone ID is displayed
in guardroom phone.
> Communication with guardroom maintains (for 3 minutes). When communication is ended,
device returns to standby mode.
(Stand-by) (House Number) (Call state) (Communication state) (Stand-by)
(Stand-by) (Guard Master Number) (Call state) (Communication state) (Stand-by)
89
▷
Password Change
(Password change function is only available during the call with house.)
Pressing“# # 0 0 #”during the call with house,“- - - - ”is displayed.
Input new password and press“#” button.
e.g) When register passward as ‘1111’. (It should be 4 digits)
▷
Door open using lobby phone with password
Pressing“house number + # + password + #”designated by the house, door is automatically opened.
when the user from house number “0101” opens common gate with passward.
e.g) Press house number“0101”, #, passward and # in order.
(Communication state) (Password input mode) (Hold) (Password) (# Button)
(Stand-by) (House Number) (# Button) (Password) (# Button) (Releasing common gate)

[Lobby Phone's Direct-Button Call Function]
Model : KDP-104, KDP-108, KDP-112, KLP-104, 108, 112, KLP-P104, P108, P112,
KLP-C104, C108, C112
To call to house, press house number using lobby phone's key pad.
Tone sound rings and call signal is sent to the house.
Pressing the call button again while calling, calling is cancelled. No separate cancel button is offered.
If called house is communicating with extended other lobby phones or guardroom phone,
busy signal sounds and device immediately returns to stand-by mode.
▷Operation of Door Opener While Communicating with House
1. Pressing door open button during the communication with house, common gate is opened.
(Door Opener Specification: Within DC 12V 300mA)
※Functional specifications may be changed according to the specifications of installed products.
10 11
The numbers are the setting number
when the switch is put to ON.
1. If DIP SWITCH from 1 to 12 is put to ON, the numbers of DIP SWITCH will be
summed up.
ex1) If the switches 1 and 2 are put to ON, the setting number becomes 1+2=3.
ex2) If the switches 1 and 3 are put to ON, the setting number becomes 1+4=5.
ex3)
ex1)
ex2)
DIP Switch Setting at House Interphone and Video Phone
■OLD MODE : It is compatible with the existing units. ID is available with 1~63, 1000~1963,
2000~2963, 3000~3963.
There should be no mixed protocol in a system. Mixed protocol in a system can make
the malfunction of system.
In this case, DIP SWITCH 1, 3, 4, 7, 8, 12 is
put to ON, the result is 1+4+8+100+200+
2,000=2313, the house No.2313
1,000 - digit
100 - digit
1, 10 - digit

ex4)
ex5)
ex6)
ex7)
In this case, DIP SWITCH 1,9, 11, 12 is
put to ON, the result is 1+400+1000=1401,
the house No.1401
In this case, DIP SWITCH 1, 2, 7 is
put to ON, the result is 1+2+100=103,
the house No.103
In this case, DIP SWITCH 4, 8 is
put to ON, the result is 8+200=208,
the house No.208
In this case, DIP SWITCH 1, 3. 10 is
put to ON, the result is 1+4+800=805,
the house No.805
12 13
In this case, DIP SWITCH 2, 7, 11, 12 is
put to ON, the result is 2+100+1000+2000
=3102, the house No.3102
ex8)
ex9)
ex10)
In this case, DIP SWITCH 1, 10, 11, 12 is
put to ON, the result is 1+800+1000+2000
=3801, the house No.3801
In this case, DIP SWITCH 2, 6, 7, 11, 12 is
put to ON, the result is 2+32+100+1000+2000
=3134, the house No.3134

2. Precautions for DIP Switch Setting (House No. Setting)
1) After setting DIP switches, device power should be reset.
(In power switch ON state, DIP switches cannot be set.)
2) For direct button type lobby phone, up to 12 houses can be set.
Thus, when DIP switches of house interphone and video phone are set, available houses are also 1 to 12
in number.
For Common gate pannel (KDP-104/KDP-108/KDP-112) and Lobby Phone (KLP-104/KLP-108/KLP-112,
KLP-C104/KLP-C108/KLP-C112, KLP-P104/KLP-P108/KLP-P112), house (KVM-520 and KIP-603,
KIV-102, KIV-D102, KIV-212, KIV-D212, KCV-802R, KCV-D802R) No. setting should be conducted
as following instructions. (A specification preset by internal protocol)
House No. (DIP Switch) Setting for direct button type.
(Warning!) House device should be set as described above (Fix house No. type).
3) If user wants to use interphone or video phone as sub-phone, all DIP switches should be in OFF state.
4) When user sets DIP switches, excessive impact on DIP switches may cause abnormal or erroneous
operation of device.
11
9
7
5
3
1
A
12
10
8
6
4
2
B
House Setting No.
14 15
The numbers are the setting number
when the switch is put to ON.
1. If DIP SWITCH from 1 to 12 is put to ON, the numbers of DIP SWITCH will be
summed up.
ex1) If the switches 1 and 2 are put to ON, the setting number becomes 1+2=3.
ex2) If the switches 1 and 3 are put to ON, the setting number becomes 1+4=5.
DIP Switch Setting at House Interphone and Video Phone
■ NEW MODE : It is available to set from No. 1~1599.
1) DIP SW 1~4, it is available by 15, the sum of 1248. In case of 2 digits from 9
are available by No.9. And 10~15(A~F HEX code)’ s setting is 9.
2) DIP SW 5~8 is available by 15, the sum of 1248. In case of 2 digits from 9
are available by No.9. And 10~15(A~F HEX code)’ s setting is 9.
3) DIP SW 9~12 is available by 15, the sum of 1248.
※There should be no mixed protocol in a system. Mixed protocol in a system can make
the malfunction of system.
※KIP-120 and KLP-100 Series only matching with over 4.0 version’s NEW MODE.
100~1,500
10~90
1`~9
800
400
200
100
80
40
20
10
8
4
2
1
ex1)
ex2)

ex3) To set the house No.999
ex4) To set the house No.1203
In this case, DIP SWITCH 1, 4, 5, 8, 9, 12 is
put to ON, the result is
1+8+10+80+100+800=999, the house No.999
In this case, DIP SWITCH 1, 2, 11, 12 is put to
ON, the result is 1+2+400+800=1203, the
house No.1203
16 17

18 19
MemoMemo
This manual suits for next models
1
Table of contents
Other KOCOM Intercom System manuals

KOCOM
KOCOM DP-203HA Guide

KOCOM
KOCOM KCV-A374SD User manual

KOCOM
KOCOM KDP-501A Instruction Manual

KOCOM
KOCOM KIP-300 User manual

KOCOM
KOCOM KDP-601AM Instruction Manual

KOCOM
KOCOM KDP-602GD User manual

KOCOM
KOCOM KLP-305 series Manual

KOCOM
KOCOM IP-201P Guide

KOCOM
KOCOM KIP-304 User manual

KOCOM
KOCOM KC-MC35 User manual

KOCOM
KOCOM KC-C60 User manual

KOCOM
KOCOM KIP-605PG Instruction Manual

KOCOM
KOCOM KLP-420 series User manual

KOCOM
KOCOM KCV-352 / D352 User manual

KOCOM
KOCOM KIP-120 Instruction Manual

KOCOM
KOCOM KVM-301 Manual

KOCOM
KOCOM KDP-601A User manual

KOCOM
KOCOM KIP-601PM Instruction Manual

KOCOM
KOCOM KC-C60 Manual

KOCOM
KOCOM KIP-612ML Instruction Manual