1387024-2A-E 1
1387024-2A-E 8
INSTALLATION INSTRUCTIONS
URBANITY+
URBANITY+
SERVICE PARTS
**Color code must be specified when ordering.
NOTE: For all Asia pacific regions (excluding China) add SP (SPxxxxxxx**) in front of the part number when ordering.
BEFORE YOU BEGIN
All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right
to make changes in product characteristics, packaging, or availability at any time without notice.
Please leave these instructions for the consumer. They contain important information.
23751T-9 Thermostatic Dual Shower Column With Multifunction Showerhead
23752T-9 Thermostatic Dual Shower Column With Beitou Showerhead
23861T-9 Thermostatic 3 Way Shower Column With Multifunction Showerhead
23749T-9 Thermostatic 3 Way Shower Column With Beitou Showerhead
23861T-9 Thermostatic 3 Way Shower Column With Multifunction Showerhead
23749T-9 Thermostatic 3 Way Shower Column With Beitou Showerhead
STANDARD APPLICABLE
TOOLS AND MATERIALS (USER SUPPLIED)
Adjustable Wrench Level Drill Pencil Screwdrivers Sealant Tape
OPERATION INSTRUCTIONS
1. Minimum supply pressures: 0.1MPa(1bar).
2. Recommended supply static pressures: 0.3MPa(3bar) on hot and cold water.
3. Supply pressure greater than 0.5MPa(5bar): install a pressure reducer.
4. Hot water temperatures, minimum: 50ºC, maximum: 80ºC.
5. Recommended hot water temperature: 65ºC(energy-saving).
6. Setting range, approximately: 20ºC to 49ºC.
7. Safety stop at: 37ºC.
8. Maximum mixed water temperature: 49ºC.
9. The highest environment temperature for handshower & showerhead is 60ºC. Please keep handshower, showerhead
and shower arm away from heater, or it may become damaged and cause injury to the user.
OPERATION CONDITION
The temperature is set by slowly turning the temperature handle(right-hand handle). For safety reasons, there is a stop
that limits temperature to 37ºC. To get a higher temperature, push the button(on right-handle) and continue turning the
temperature handle counter-clockwise.
Water flow and dispense is set by switch buttons. Press any switch button on the faucet body, the water will run from
corresponding outlet. Rotate the switch buttons counter-clockwise to reduce flow.
Handshower
Icon description above switch button
Bath spout
(For 23861T & 23749T)
Laminar
(For 23751T & 23861T)
Kloud burst
(For 23752T & 23749T)
Katalyst rain
Special model meets or exceeds the following at date of manufacture: TIS
1069458
77420
1410662-CP
(For CY finish)
1348571**
(For other finishes)
833438
833730
3008304
1299843**
3008523
870721
871527
834404
1244920
1299826
1315911
1347562
1299821
1299824
1259076
870992
831752
871472
1299825
3019692
1391738
864922**
1299837
1299846
1176766
1242353
1299857
1242354
1082902 42451
1355155**
1362566
3010643
1082904
1355154
1355156**
1355153**
834638
1248781**
1326364
1249005
833730
1242635
1359717
1424353-CP
(For 23749T-9-CY)
1407705**
(For 23749T-9
other finishes)
1424140-CP
(For 23861T-9-CY)
1359706**
(For 23861T-9
other finishes)
1242635
1326364
1249005
833730
55925
1377201
1423819**
1424141-CP
(For CY finish)
1362786**
(For other finishes)
1387024-2A-E 2
1387024-2A-E 7
ROUGH-IN DIMENSIONS (23751T & 23752T)
The Finished Floor
23751T-9 Thermostatic Dual Shower Column With Multifunction Showerhead
23752T-9 Thermostatic Dual Shower Column With Beitou Showerhead
URBANITY+
SERVICE PARTS
**Color code must be specified when ordering.
NOTE: For all Asia pacific regions (excluding China) add SP (SPxxxxxxx**) in front of the part number when ordering.
440
1119
60
49
G1/2˝
1035
882
15
20
46
167
40
Ø37
302
150±10
149
Ø42
126
Recommended Height
1000~1100
23752T-9 Showerhead
233
335
23751T-9 Showerhead
283
450
24
1410662-CP
(For CY finish)
1348571**
(For other finishes)
1069458
77420
833438
833730
3008304
1299843**
3008523
870721
871527
834404
1244920
1299826
1315911
1347562
1299821
55925
1377201
1423819**
1299824
1259076
870992
831752
871472
1299825
3019692
1391738
864922**
1299837
1299846
1176766
1242353
1299857
1242354
1082902 42451
1355155**
1362566
3010643
1082904
1355154
1355156**
1355153**
834638
1248781**
1326364
1249005
833730
1242635
1359717
1242635
1326364
1249005
833730
1424141-CP
(For CY finish)
1362786**
(For other finishes)
1424353-CP
(For 23752T-9-CY)
1407705**
(For 23752T-9
other finishes)
1424140-CP
(For 23751T-9-CY)
1359706**
(For 23751T-9
other finishes
1387024-2A-E 3
ROUGH-IN DIMENSIONS (23861T & 23749T)
The Finished Floor
1387024-2A-E 6
CLEANING INSTRUCTIONS
Stop pin
Notch
2. Remove the screw(31) and adapter spline(32), and
then unscrew the nut(34) and stopper(33). Remove
the cartridge cautiously. Clean the thermostatic
cartridge by soaking it in warm vinegar.
2
Cartridge
3 4
Notch
Stop pin
5
Groove
Round mark
6
①
②
26
29
30
31
32 28
31
32
33
34
1
②
Number 37
①
26
29
30
28
Recommended Height
1000~1100
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth.
Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the
finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
3. After cleaning, install the “stop assembly” back on
the cartridge, adjust the stop pin into the notch.
4. Install the assembly cartridge and stop in the body,
adjust the stop pin into the notch.
5. NOTE: Do not turn the cartridge when reinstalling it.
If you turned it accidentally, you should adjust it and be
sure that the round mark is correctly in line with the
groove, or readjust as per the steps of verification and
setting.
6. Install the adapter spline(without turning the spindle).
Ensure the indicator line on the adapter spline align with
the indicator line on the stopper. Tighten the screw(31)
with a screwdriver. Install the temperature handle(28).
Ensure the number 37 on temperature handle is upward
vertically(After assembly, it could not be turned counter-
clockwise if not pushing the button). Tighten the screw
(29) with 2.5mm hex wrench(26). Insert the plug(30).
Clear the Thermostatic Cartridge
Very hard water can obstruct the filters on the thermostatic cartridge and reduce the water flow. Please clean the cartridge
as follows: Shut off the water supply of the faucet and turn on the water flow valve, then proceed to remove the cartridge.
The cartridge is sensitive part, please be careful.
1. Before your action, make sure the number 37 on the
temperature handle is upward vertically(It could not be
turned counter-clockwise if not pushing the button).
Remove the temperature handle(28).
Indicator line
Upward
horizontally
46
167
302
150±10
40
Ø37
440
15
20
1119
1035
882
75
49
127
31º
G1/2˝
149
Ø42
126
233
283
450335
23749T-9 Showerhead23861T-9 Showerhead
24
1387024-2A-E 5
1387024-2A-E 4
Slot
Protector cap
Restrictor 23
25
26 27
24
Clear the Filter
The filters can protect the faucet, but it may get obstructed and
reduce water flow after a long time of use. If this happens, turn off
the water supply, uninstall the shower column.
Take out the plugs(17). Unscrew two screws(4) with 3mm hex
wrench(3) to uninstall the faucet. Take out the filters by hand.
Clean the filters by soaking them in warm vinegar. Reinstall them
in turn.
CARE AND MAINTENANCE
INSTALLATION CHECKOUT
Number 37
Ensure that all connections are tight, the switch buttons are not
turned on. Turn on the water supply. Run water through the valve.
Check for leakage. Repair as needed.
Press the buttons separately. Check whether all connections and
water flow are well. Shut off the faucet.
Verification and Setting
Make sure that the water feeds of the faucet have reach the
highest temperature by running the water sufficiently. When the
number 37 on the temperature handle(28) is upward vertically,
the water temperature should be within a range of 36ºC and 38ºC,
as measured by a thermometer. If not, the installer can adjust the
setting. Proceed with the setting as follows:
Remove the plug(30). Take out the screw(29) with 2.5mm hex
wrench(26) to uninstall the temperature handle(28). Remove the
screw(31) with a screwdriver. Remove the adapter spline(32).
Under the normal condition of water flow, slowly turn the
temperature selector(Always in the same direction) from the cold
water position until water temperature reaches 37ºC. If the
temperature goes over 37ºC, go back to the “cold” setting and
reset it. When the temperature is stable, do not turn the cartridge
spindle. Install the adapter spline. Ensure the indicator line on the
adapter spline align with the indicator line on the stopper. Tighten
the screw(31) with a screwdriver. Install the temperature handle.
Ensure the number 37 on the temperature handle is upward
vertically(After assembly, it could not be turned counter-clockwise
if not pushing the button). Tighten the screw(29) with 2.5mm hex
wrench. Insert the plug(30).
Install the Showerhead
Before installation, install the restrictors if needed. Install the
restrictors into the connectors on the showerhead(23).
Remove the protector caps from the tube kit outlet(24) and
showerhead separately. Insert the showerhead to the tube kit
outlet as shown.
Insert the pin(25) into the slot. Tighten the screw(27) with 2.5mm
hex wrench(26).
WARNING: Ensure the screw is tightened to avoid the product
falling and personal injury.
Install the Body
To perform installation, installer must provide G1/2″ female supply
fittings(1), spaced 150mm apart, horizontally and vertically to the
finished flat wall. Flush the water supply pipes thoroughly to
remove any debris.
NOTE: Apply water pressure test on water supply pipes before
installing the connectors(2).
Apply enough tape or suitable sealant on threads of connectors.
Install two connectors into the hot and cold supply pipes.
Adjust the center-to-center distance between the connectors to
150mm horizontally. They should extend 36~45mm beyond the
finished wall. NOTE: Rotate the C-rings with their openings
downward, and pull forward the C-rings to clamp the connectors.
Adjust two screws(4) with 3mm hex wrench(3). Install the faucet
body to the connectors until it is against the finished wall.
Pre-tighten two screws with 3mm hex wrench(The screws should
contact with the connectors through the C-rings’ openings).
Tighten them after completing the installation of shower column.
INSTALLATION
Install the Shower Column and Handshower
Rehearse the shower column kit installation for the base
mounting location determination.
1. Remove the protector cap from the connecting pipe(5). Insert
the shower column onto the connecting pipe firmly to the end.
2. Put the mounting base(6) into the column insert(7)(Make sure
the shower column is vertical. Check whether it is vertical with the
level(8)). Mark the location of the mounting base with a pencil.
3. Uninstall the shower column. Mark the holes of the mounting
base with a pencil.
Install the mounting base.
1. Drill Ø10mm holes(The depth is not less than 45mm) on the
marks.
2. Insert the anchors(9) into the holes. Tighten the screws(10) with
a screwdriver in order to secure the mounting base.
Install the shower column.
1. Slide the shower bracket(11) into the shower column. Install
the shower column to the mounting base(6) and connecting
pipe(5) firmly to the end.
2. Tighten the screws(14) and washers(13) with 4mm sphere hex
wrench(12). Install the cover(15). Put the cap(16).
3. Ensure the upper surface of the faucet body is horizontal with
the level(8). Tighten two screws(4) with 3mm hex wrench. Press
the plugs(17) into the faucet.
Install the handshower.
1. Remove the protector cap from the connector(21). Put the
screen washer(18) into the shower hose(19). Connect the
connector(21) and handshower(20) with hose. NOTE: Do not over
tighten.
2. Install the check valve(22) into the handshower if needed.
3. Hang the handshower on the shower bracket(11).
26
28
29
30
31
32
Upward
horizontally
Spindle
Indicator line
4
3
17
Filter
36~45mm
4
3
Cold
Hot
Cold
Hot
1
2
150mm
Opening
downward
Screw
C-ring
5
8
14
13
12
10
6
9
7
16
Protector cap
Protector cap
15
4
3
21
11
22
19
20
18
17

This manual suits for next models

3

Other Kohler Plumbing Product manuals

Kohler K-690 User manual

Kohler

Kohler K-690 User manual

Kohler K-377 Assembly instructions

Kohler

Kohler K-377 Assembly instructions

Kohler 78980T-DR User manual

Kohler

Kohler 78980T-DR User manual

Kohler K-18493 User manual

Kohler

Kohler K-18493 User manual

Kohler K-13491 Assembly instructions

Kohler

Kohler K-13491 Assembly instructions

Kohler Cantata K-2199 User manual

Kohler

Kohler Cantata K-2199 User manual

Kohler K-6330 User manual

Kohler

Kohler K-6330 User manual

Kohler K-10430 Assembly instructions

Kohler

Kohler K-10430 Assembly instructions

Kohler K-13490 Assembly instructions

Kohler

Kohler K-13490 Assembly instructions

Kohler KARAT K-17555 User manual

Kohler

Kohler KARAT K-17555 User manual

Kohler C3-130 User manual

Kohler

Kohler C3-130 User manual

Kohler 1093479-2-B Assembly instructions

Kohler

Kohler 1093479-2-B Assembly instructions

Kohler K-15599X User manual

Kohler

Kohler K-15599X User manual

Kohler Deerfield 5815W User manual

Kohler

Kohler Deerfield 5815W User manual

Kohler K-T10592 User manual

Kohler

Kohler K-T10592 User manual

Kohler Clearflo K-7147 Assembly instructions

Kohler

Kohler Clearflo K-7147 Assembly instructions

Kohler K-393 User manual

Kohler

Kohler K-393 User manual

Kohler Discovery User manual

Kohler

Kohler Discovery User manual

Kohler K-1913 Assembly instructions

Kohler

Kohler K-1913 Assembly instructions

Kohler K-9245 Assembly instructions

Kohler

Kohler K-9245 Assembly instructions

Kohler K-7437 User manual

Kohler

Kohler K-7437 User manual

Kohler K-T16236 User manual

Kohler

Kohler K-T16236 User manual

Kohler COUTURE WATERGUARD User manual

Kohler

Kohler COUTURE WATERGUARD User manual

Kohler K-6356 User manual

Kohler

Kohler K-6356 User manual

Popular Plumbing Product manuals by other brands

Moen SANI-STREAM 8797 manual

Moen

Moen SANI-STREAM 8797 manual

Grohe Allure Brilliant 19 784 manual

Grohe

Grohe Allure Brilliant 19 784 manual

Cistermiser Easyflush EVO 1.5 manual

Cistermiser

Cistermiser Easyflush EVO 1.5 manual

BEMIS FNOTAB100 Installation instruction

BEMIS

BEMIS FNOTAB100 Installation instruction

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Akw Stone Wash Basin Installation instructions manual

Akw

Akw Stone Wash Basin Installation instructions manual

Enlighten Sauna Rustic-4 user manual

Enlighten Sauna

Enlighten Sauna Rustic-4 user manual

Moen ShowHouse S244 Series quick start guide

Moen

Moen ShowHouse S244 Series quick start guide

Sanela SLWN 08 Mounting instructions

Sanela

Sanela SLWN 08 Mounting instructions

Franke 7612982239618 operating instructions

Franke

Franke 7612982239618 operating instructions

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Heritage Bathrooms

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Tres TOUCH-TRES 1.61.445 instructions

Tres

Tres TOUCH-TRES 1.61.445 instructions

STIEBEL ELTRON WS-1 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON WS-1 Operation and installation

Miomare HG00383A manual

Miomare

Miomare HG00383A manual

BELLOSTA revivre 6521/CR1 quick start guide

BELLOSTA

BELLOSTA revivre 6521/CR1 quick start guide

American Standard Heritage Amarilis 7298.229 parts list

American Standard

American Standard Heritage Amarilis 7298.229 parts list

BorMann Elite BTW5024 quick start guide

BorMann

BorMann Elite BTW5024 quick start guide

Moen 1225 quick start guide

Moen

Moen 1225 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.