ABOUT Your CM2-RC2
INSTALLATION INSTRUCTIONS
IT IS IMPORTANT TO READ THE FOLLOWING INSTRUCTIONS CAREFULLY. DAMAGE TO THE
PRODUCT OR TO INSTALLER AND PROPERTY COULD RE-SULT IF INSTRUCTIONS ARE NOT
FOLLOWED. Important Safety Precautions
1. Do not connect the power source until after the unit is mounted. Shock and/or damage
could result.
2. Be sure to shut the unit off prior to any service work.
3. Wear gloves to protect hands during installation as well as to keep the surface of air
cleaner free from dirt and smudges.
Equipment Needed for Installation
1. Regular and Phillips Screwdrivers
2. Wire cutters
3. Pliers
4. Twelve gauge galvanized wire for hanging the wires from the true ceiling to the top of the
unit (if threaded rod is to be used, it will replace the wire.).
5. Enough twelve or fourteen gauge electrical wire and conduit to reach the nearest
switched circuit. (see Electrical Instructions)
6. Junction box fittings as required.
Items Supplied as Loose Parts
1. Four (4) black 1/4 x 20 eyebolts
The CM2-RC2 air purifier was designed to provide long service. The unit was designed to be
easily repairable. The product warranty is 7 years but you can expect 15 or more years of
useful product life. The CM2-RC2 is a heavy duty all air purifier. There are no circuit boards.
We use simple switches that if necessary are easy to replace.
Unpacking
Your CM2-RC2 air purifier is shipped on a 27" x 27 " pallet. If you ever need to ship your air
purifier back to the factory it MUST be shipped strapped to a pallet. The CM2-RC2 was
designed to be easily repaired so it is unlikely to need to ship your unit back. Care should be
taken while unpacking the MAX Guard. The unit weighs about 80 pounds and the box should
be placed in the upright position. It may be necessary to slice the corners of the box if you are
unable to lift the unit out.
Preparation for Mounting
The CM2-RC2 is designed to fit into a T-bar drop ceiling. Remove as many of the ceiling
tiles as is necessary to safely and securely mount the air cleaner. The area between the
true ceiling and the drop ceiling must be at least 13”. There must be no duct work, pipes,
or other obstructions to the area where the unit is to fit. Make sure that the spot chosen
will be oriented for good air circulation.