INSTALLATION INSTRUCTIONS
F-4541
LOOP HANGER INSTALLATION – HL (FIGURE 3)
1. Remove refractor/ reector per Figure 1.
2. Disconnect cord from luminaire.
3. Wire cord leads to power supply leads using connectors suitable
for the gauge and number of wires being used. Black xture
lead connects to the supply conductor, white xture lead
connects to the neutral supply conductor, and the grounding
wire must be connected to a suitable ground.
4. Hang luminaire by attaching to user supplied chain or cables.
5. Install lamp(s) if applicable
6. Re-install refractor/ reector.
7. Connect power cord.
8. As a safety recommendation, an additional 1/16" diameter
aircraft cable (not included) should be used to attach the loop
hanger and supporting structure.
FIGURE 3
1. Remove refractor/ reector per Figure 1.
2. Connect threaded hub for ½" diameter rigid pendant (12"
size) or ¾" diameter rigid pendant (16"/22” size). Pendant
components by others.
3. Undo lock nut and slide housing/ cover up.
4. Install safety aircraft cable per Figure 2.
5. Pull wires into the luminaire.
6. Wire luminaire leads to power supply leads using connectors
suitable for the gauge and number of wires being used.
Black xture lead connects to the supply conductor, white
xture lead connects to the neutral supply conductor, and the
grounding wire must be connected to a suitable ground.
7. Slide housing/ cover down and tighten lock nut
8. Install lamp(s) if applicable
9. Re- install refractor/ reector.
PENDANT MOUNT INSTALLATION – (EXCEPT 320M-400M) PM (FIGURE 4)
FIGURE 4