Lenovo Storage S3200 8
Table 1. Technical specifications (Part 2)
Components Specification
Drive
connectivity
Dual-ported 6 Gb SAS drive attachment infrastructure.
Controller enclosure with one or two RAID controllers (ports per one controller):
24x 6 Gb SAS internal drive ports (SFF chassis)
12x 6 Gb SAS internal drive ports (LFF chassis)
1x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion port for the attachment of the external
drive enclosures
Drive expansion enclosure with one or two expansion modules (ports per one module):
24x 6 Gb SAS internal drive ports (SFF chassis)
12x 6 Gb SAS internal drive ports (LFF chassis)
2x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion ports (IN and OUT) for the daisy chained
attachment of the external drive enclosures
Drives SFF drives:
400 GB, 800 GB, and 1.6 TB SAS SSDs
300 GB and 600 GB 15K rpm SAS HDDs
600 GB, 900 GB, and 1.2 TB 10K rpm SAS HDDs
1 TB 7.2K rpm NL SAS HDDs
LFF drives:
400 GB SAS SSDs
600 GB and 900 GB 10K rpm SAS HDDs
2 TB, 4 TB, and 6 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 576 TB (96x 6 TB NL SAS HDDs)
Host connectivity S3200 SAS controller: 4x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
S3200 FC and iSCSI controller: 4x SFP/SFP+ host ports with two built-in dual-port CNCs (each
port on the same CNC must have the same connectivity type, different CNCs might have
different connectivity types)
CNC host port options (per each CNC on the RAID controller):
2x 1 Gb iSCSI SFP (1 Gb speed, UTP, RJ-45)
2x 10 Gb iSCSI SFP+ (1/10 Gb speeds, SW fiber optics, LC)
2x 8 Gb FC SFP+ (4/8 Gb speeds, SW fiber optics, LC)
2x 16 Gb FC SFP+ (4/8/16 Gb speeds, SW fiber optics, LC)
2x 10 Gb iSCSI SFP+ DAC cables
Host operating
systems
Microsoft Windows Server 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 6 and 7;
SUSE Linux Enterprise Server (SLES) 10, 11, and 12; VMware vSphere 5.5 and 6.0.
Standard
software features
Intelligent Real-time Tiering for HDDs, Virtualized Storage Pools, Thin Provisioning, SSD Read
Cache, Rapid RAID Rebuild, Snapshots - up to 128 targets.
Optional features Intelligent Real-time Tiering for SSDs, Snapshots - up to 1,024 targets.
Performance Dual controller configuration:
Up to 120,000 random read IOPS (4 KB blocks)
Up to 6.4 GBps sequential read throughput (512 KB blocks)
Up to 5.3 GBps sequential write throughput (512 KB blocks)
Configuration
maximums
Per system:
Maximum number of virtual storage pools: 2 (1 per controller)
Maximum number of logical volumes (total/mapped): 2,048/1,024
Maximum logical volume size: 128 TB
Maximum number of drives in a drive group: 16
Maximum number of drive groups: 32
Maximum global spares: 16
Maximum number of initiators: 8,192 (1,024 per port)
Maximum number of hosts in a host group: 256
Maximum number of host groups: 32
Maximum number of initiators per host: 128
Maximum number of snapshots: 1,024 (requires an optional license)