manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lenze
  6. •
  7. DC Drive
  8. •
  9. Lenze L-force Series User manual

Lenze L-force Series User manual

Montageanleitung
EDK84VHCE453
.Cô:
Ä.Cô:ä
8400 30 ... 45 kW

E84AVHCExxxx HighLine C
Frequenzumrichter
Frequency Inverter
Convertisseur de fréquence
Convertidor de frecuencia
Inverter di frequenza
Mounting Instructions
Instructions de montage
Instrucciones para el montaje
Istruzioni per il montaggio
L−force Drives


2
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
0
V
Warnings!
Operation of this equipment requires detailed installation and operation instructions
provided in the Hardware manual intended for use with this product. This information
is provided on the CD−ROM included in the container this device was packaged in. It
should be retained with this device at all times. A hard copy of this information may
be ordered by phone or e−mail, printed on the back of this document.
Avertissements !
Pour assurer le bon fonctionnement de cet équipement, se conformer aux instructions
d’installation et de mise en service contenues dans le manuel correspondant et
régissant l’utilisation de ce produit. Ces informations sont contenues sur le CD−ROM
compris dans l’emballage livré, qui doit être consultable à tout moment. Une version
papier de ces informations peut être commandée par téléphone ou par mail
(coordonnées figurant au dos du présent document).
Gefahr!
Gefährliche elektrische Spannung
ƒDie Leistungsanschlüsse X100 und X105 führen bis zu 3 Minuten nach
Netz−Ausschalten gefährliche elektrische Spannung.
Mögliche Folgen:
ƒTod oder schwere Verletzungen beim Berühren der Leistungsanschlüsse.
Schutzmaßnahmen:
ƒVor Arbeiten am Gerät Netzspannung ausschalten und mindestens 3 Minuten
warten.
ƒPrüfen, ob alle Leistungsanschlüsse spannungsfrei sind.
Beachten Sie auch weitere wichtige Informationen zur Geräte− und Sicherheitstechnik auf der
beiliegenden CD−ROM!


3
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
Danger!
Dangerous voltage
ƒThe power terminals X100 and X105 carry dangerous voltages for up to 3 minutes
after mains disconnection.
Possible consequences:
ƒDeath or severe injury if the power terminals are touched.
Protective measures:
ƒSwitch off the mains voltage and wait at least 3 minutes before starting to work on
the device.
ƒCheck that all power terminals are deenergised.
Please also observe more important information on device and safety technology provided on the
enclosed CD−ROM!
Danger !
Tension électrique dangereuse
ƒLes raccordements de puissance X100 et X105 sont susceptibles de véhiculer une
tension dangereuse jusqu’à 3 minutes après une coupure réseau.
Risques encourus :
ƒMort ou blessures graves en cas de contact avec les raccordements de puissance
Mesures de protection :
ƒAvant toute manipulation de l’appareil, couper la tension réseau et attendre 3
minutes au minimum.
ƒS’assurer que tous les raccordements de puissance sont hors tension.
Veuillez également tenir compte des consignes importantes sur la technologie des appareils et les
fonctions de sécurité comprises sur le cédérom joint !
¡Peligro!
Voltaje eléctrico peligroso
ƒLas conexiones de potencia X100 y X105 siguen vivas hasta 3 minutos después de
la desconexión de red.
Posibles consecuencias:
ƒMuerte o serias lesiones al tocar las conexiones de potencia.
Medidas de protección:
ƒAntes de trabajar en el equipo, desconectar la alimentación de red y esperar por lo
menos 3 minutos.
ƒComprobar, si todas las conexiones de potencia están libres de voltaje.
Observe también la información importante sobre aspectos relativos a la técnica del dispositivo


4
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
y de seguridad incluida en el CD−ROM adjunto!
Pericolo!
Tensione elettrica pericolosa
ƒI collegamenti di potenza X100 e X105 presentano una tensione elettrica pericolosa
fino a 3 minuti dopo la disinserzione della rete.
Possibili conseguenze:
ƒMorte o gravi lesioni in caso di contatto con i collegamenti di potenza.
Misure di protezione:
ƒAttendere almeno 3 minuti prima di eseguire qualsiasi intervento sui collegamenti
di potenza.
ƒControllare tutti i collegamenti di potenza per accertare l’assenza di tensione.
Osservare anche le ulteriori informazioni importanti relative a installazione e sicurezza incluse nel
CD−ROM allegato!

30  45 kW

5
EDK84VHCE453 DE/EN/FR/ES/IT 1.3

30  45 kW
8400HLC091

30  45 kW

6
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
30  45 kW
8400HLC092
[mm] 130  45 kW

7
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
1
[mm]
30  45 kW
8400GG108e
h b t h1h2t1g1g2g3
[kW] [mm]
E84AVHCE3034xXx30
450 250 250 520 636 237 8.5 16 18
E84AVHCE3734xXx37
E84AVHCE4534xXx45
E84AVHCE3034xBx30
450 250 270 520 636 257 8.5 16 18
E84AVHCE3734xBx37
E84AVHCE4534xBx45
[mm] 130  45 kW

8
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
8400GG108d
d1d2d3c c1c2c3i j11 j21
[kW] [mm] [kg]
E84AVHCE3034xXx30
8 12 500 40 20 20 210 0 > 95 > 120 17.2
E84AVHCE3734xXx37
E84AVHCE4534xXx45
E84AVHCE3034xBx30
8 12 500 40 20 20 210 0 > 95 > 120 17.3
E84AVHCE3734xBx37
E84AVHCE4534xBx45
X100 (400 V) 230  45 kW

9
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
2
X100 (400 V)
30  45 kW
X100 − TN, TT
3/N/PE AC 400 V / 500 V
L1
L2
L3
N
PE
F1…F3
K
Z
PE L3
L1 +UG -UG
L2
X100
8400GG090a 8400GG007
X100 − IT
3/N/PE AC 400 V / 500 V
L1
L2
L3
N
PE
F1…F3
K
PE L3
L1 +UG -UG
L2
X100
8400GG090b 8400GG008
FL1, L2, L3 PE
EN 60204 UL
[A] [A] [A] [A] [mm2]
[AWG]
[mm] [Nm]
[lb−in]
[mm2]
[AWG]
[mm] [Nm]
[lb−in]
E84AVHCE3034 80 C80 − − − −
16 ... 50
6 ... 0 24 4.0
35
2.5 ... 25
12 ... 2 16 4.0
35
E84AVHCE3734 100 C100 − − − −
E84AVHCE4534 125 C125 − − − −
X101 330  45 kW

10
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
3
X101
30  45 kW
X101
NC
COM
X101
NO
8400GG090c 8400GG010
COM, NC, NO
[mm2]
[AWG]
[mm]
E84AVHCE3034
E84AVHCE3734
E84AVHCE4534
0.2 ... 1.5
24 ... 16 10
X105, X106 430  45 kW

11
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
4
X105, X106
30  45 kW
8400GG093
X105 X106
;
;;
;
84MOTL001_a 84MOTL001_b
U, V, W PE T1, T2
b c e a d f g h
[mm] [mm2]
[AWG]
[Nm]
[lb−in]
[mm] [mm2]
[AWG]
[Nm]
[lb−in]
[mm] [mm2]
[AWG]
E84AVHCE3034
E84AVHCE3734
E84AVHCE4534
40 190 24 16 ... 50
6 ... 0
4.0
35 250 16 2.5 ... 25
12 ... 2
4.0
35 240 40 10 0.2 ... 1.5
24 ... 16
X105 430  45 kW

12
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
X105
30  45 kW
X105 − TN, TT
PEWV
U
J>
M
3~
M
3~
T1
PTC
"
X105
Rb1
T2
T1
T2
+
+
+
Rb2
8400GG094a 8400GG013
X105 − IT
PEWV
U
J>
M
3~
M
3~
T1
PTC
"
X105
Rb1
T2
T1
T2
+
+
+
Rb2
8400GG094b 8400GG013
X106 430  45 kW

13
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
X106
30  45 kW
X106
J>
M
3~
M
3~
PTC
"
X106
+
+
T1 T2
8400GG094c 8400GG017
X80 5E84A...xxBx

14
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
5
X80
E84A...xxBx
8400HLC086
[mm] [mm2]
[AWG]
0.2 ... 1.5
24 ... 16
84MOTL001_g
X80
DO1SIB
GI
SIA GO
DC 24 V
(+19.2...
+28.8 V)
X80 24O
8400HLC064 8400HLC045
X1, X3, X4, X5, X107 6HighLine

15
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
6
X1, X3, X4, X5, X107
HighLine
8400HLC043
X1 X3, X107 X4, X5
;
;
84MOTL001_e 84MOTL001_d 84MOTL001_f
X1 X3 X4, X5 X107
min. max. min. max. min. max.
a
[mm]
a
[mm]
[mm2]
[AWG]
a
[mm]
a
[mm]
[mm2]
[AWG]
[mm2]
[AWG]
a
[mm]
a
[mm]
[mm2]
[AWG]
110 135 0.2 ... 1.5
24 ... 16 150 175 0.2 ... 1.5
24 ... 16
0.2 ... 1.5
24 ... 16 115 140 0.2 ... 1.5
24 ... 16
X1
CAN-Ground
X1
R
CL
CH
120Ω
CG
CAN-Low
CAN-High
EDS84AVxxxx
,
""
"
CL
CH
CG
dcba6432 16 8421
Baud CAN Adress
O
N
8400HLC048 8400SLC041
X3, X4 6HighLine

16
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
X3, X4
X3
GND-A
X3
A2I
O2IA2U
O2UA1I
O1I A1U
O1U AR
GA
+10V/
10mA
0...10V
1k ... 10k
0 ... 10 V
"
8400HLC050 8400HLC012
X4
24O
DC 24 V
(+19.2...+28.8V)
X4DO1DO2
DO3
GO
GND-O
8400HLC046 8400HLC045
X5, X107 6HighLine

17
EDK84VHCE453 DE/EN/FR/ES/IT 1.3
X5, X107
X5
24 Vint.
50mA
24EDI1DI2
DI3
DI4RFR
DC 24 V
(+19.2...
+28.8V)
S1
2.7k
2.7k
3.3k
3.3k
3.3k
X5
GND-I
DI5
DI6
DI7
GI24I
1.6k
1.6k
3.3k
8400HLC047 8400HLC045
X107
24B
X107 GBBD1
BD2
"
DC24V
(+19.2...+28.8V)
M
8400HLC044 8400HLC045

© 09/2014
FLenze Drives GmbH
Postfach 10 13 52, D−31763 Hameln
Breslauer Straße 3, D−32699 Extertal
Germany
Service Lenze Service GmbH
Breslauer Straße 3, D−32699 Extertal
Germany
(+49515482−0 (008000 2446877 (24 h helpline)
Ê+49515482−2800 Ê+49515482−1112
[email protected] [email protected]
üwww.lenze.com
EDK84VHCE453 §.Cô: §DE/EN/FR/ES/IT §1.3 §TD15
10987654321

This manual suits for next models

7

Other Lenze DC Drive manuals

Lenze 8201 User manual

Lenze

Lenze 8201 User manual

Lenze 8200 motec User manual

Lenze

Lenze 8200 motec User manual

Lenze EPL10200 User manual

Lenze

Lenze EPL10200 User manual

Lenze 1.5 24 A Series User manual

Lenze

Lenze 1.5 24 A Series User manual

Lenze 8200 vector User manual

Lenze

Lenze 8200 vector User manual

Lenze E82ZAFBC201 User manual

Lenze

Lenze E82ZAFBC201 User manual

Lenze PositionServo 940 User manual

Lenze

Lenze PositionServo 940 User manual

Lenze L-force Drives 8400 User manual

Lenze

Lenze L-force Drives 8400 User manual

Lenze 2132 User manual

Lenze

Lenze 2132 User manual

Lenze L-force EYP Series User manual

Lenze

Lenze L-force EYP Series User manual

Lenze 8200 motec E82ZMFBC001 User manual

Lenze

Lenze 8200 motec E82ZMFBC001 User manual

Lenze 8400 motec Series Use and care manual

Lenze

Lenze 8400 motec Series Use and care manual

Lenze BaseLine C Series User manual

Lenze

Lenze BaseLine C Series User manual

Lenze EWS Series User manual

Lenze

Lenze EWS Series User manual

Lenze Global Drive 9300 Servo PLC Series User manual

Lenze

Lenze Global Drive 9300 Servo PLC Series User manual

Lenze L-force EWS0083 User manual

Lenze

Lenze L-force EWS0083 User manual

Lenze L-force i700 User manual

Lenze

Lenze L-force i700 User manual

Lenze L-force TopLine 8400 User manual

Lenze

Lenze L-force TopLine 8400 User manual

Lenze SMVector User manual

Lenze

Lenze SMVector User manual

Lenze L-force 8400 Series User manual

Lenze

Lenze L-force 8400 Series User manual

Lenze L-force ERBS Series User manual

Lenze

Lenze L-force ERBS Series User manual

Lenze L-force 8400 TopLine C User manual

Lenze

Lenze L-force 8400 TopLine C User manual

Lenze 9300 vector User manual

Lenze

Lenze 9300 vector User manual

Lenze 8200 vector series User manual

Lenze

Lenze 8200 vector series User manual

Popular DC Drive manuals by other brands

Bosch BDU490P Original operating instructions

Bosch

Bosch BDU490P Original operating instructions

Sumitomo Drive Technologies eye LM2 Gears CMS user manual

Sumitomo Drive Technologies

Sumitomo Drive Technologies eye LM2 Gears CMS user manual

PR electronics Hart 5107B manual

PR electronics

PR electronics Hart 5107B manual

Moons' Applied Motion Products SWM24 Quick setup guide

Moons'

Moons' Applied Motion Products SWM24 Quick setup guide

ABB ACH580-01 Series Hardware manual

ABB

ABB ACH580-01 Series Hardware manual

Piezoconcept HS1H Installation and operation manual

Piezoconcept

Piezoconcept HS1H Installation and operation manual

Electro-Craft EA4709 user manual

Electro-Craft

Electro-Craft EA4709 user manual

Oriental motor BLH Series user manual

Oriental motor

Oriental motor BLH Series user manual

M-Elec ADB-2F30BA instruction manual

M-Elec

M-Elec ADB-2F30BA instruction manual

M-Elec GD-5510 -01 instruction manual

M-Elec

M-Elec GD-5510 -01 instruction manual

Delta VFD-B Series user manual

Delta

Delta VFD-B Series user manual

Avtech AVO-6A1-B instructions

Avtech

Avtech AVO-6A1-B instructions

Becker C01 Assembly and operating instructions

Becker

Becker C01 Assembly and operating instructions

Electro-Craft CompletePower Plus user manual

Electro-Craft

Electro-Craft CompletePower Plus user manual

Oriental motor LSD-K operating manual

Oriental motor

Oriental motor LSD-K operating manual

Delta VFD-A Series user manual

Delta

Delta VFD-A Series user manual

Black Box CAT5 DB9 manual

Black Box

Black Box CAT5 DB9 manual

ABB ACS880 Series Mechanical installation instructions

ABB

ABB ACS880 Series Mechanical installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.