FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the
Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
© 2021 Leviton Mfg. Co., Inc.
FCC SUPPLIERS DECLARATION OF CONFORMITY
Smart Wallbox Sensors manufactured by Leviton Manufacturing, Inc., 201 N Service Road, Melville, NY, http://www.Leviton.com. This device complies with part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in
materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or
replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of
this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered
in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of
any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of
any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to
perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
b. With the front faceplate of the sensor removed, push both buttons on front of
sensor simultaneously for 10-15 seconds (note: after 5 seconds, a light will
blink BLUE and then alternate between BLUE and RED) and release when the
Locator Light is blinking GREEN.
NOTES:
• Use the number of LED blinks to determine which user mode the sensor is
set to. If pressed more than 8 times, it will cycle back to the start of the list.
• Auto ON/Auto OFF (10 min timeout and 1 button press) is the
DEFAULT MODE.
3. Daylighting and Night Light: The ODS15-GD is equipped with a Photocell for
Daylighting hold-off and also has a built in Night Light that can be turned ON and
configured using the Leviton Smart Sensor App.
4. Bluetooth Reset: Resets any security settings but preserves lighting and
mode settings.
a. Push button on switch for approximately 20-25 seconds until the light behind
PIR lens is flashing RED.
NOTE: Between 5-10 seconds the LED will alternate between BLUE and
RED; at 15 seconds the LED will blink YELLOW.
b. When the light flashes RED, release the button.
c. The device will reset and turn off when complete.
d. When device turns back on it will have no password set.
c. Push the bottom button to move to the next
automatic setting using the table below as
a guide.
d. When at the desired setting, press and hold
the bottom button again for 5 seconds (until
the GREEN Locator Light turns ON), when
the button is released, the light will flash the
number of times as the setting selected; the
sensor is now saved in that configuration.
e. The front cover can now be reattached. Insert
the top tabs and push in bottom tabs to attach.
For Technical Assistance Call: 1-800-824-3005 (U.S. Only) or 1-800-405-5320 (Canada Only) www.leviton.com
Button
Press
Locator
Light
Blinks
Operating Mode Sensor
Sensitivity Timeout
Daylighting
and
Night Light
1
*Default
Operation
1Auto ON / Auto OFF 75% 10mins OFF & OFF
2 2 Auto ON / Auto OFF 75% 20mins OFF & OFF
3 3 Auto ON / Auto OFF 100% 10mins OFF & OFF
4 4 Auto ON / Auto OFF 100% 20mins OFF & OFF
5 5 Manual ON / Auto OFF 75% 10mins OFF & OFF
6 6 Manual ON / Auto OFF 75% 20mins OFF & OFF
7 7 Manual ON / Auto OFF 100% 10mins OFF & OFF
8 8 Manual ON / Auto OFF 100% 20mins OFF & OFF
INDICATOR LIGHT DESCRIPTIONS
LED Location Action / Definition
RED Behind PIR Lens Blinks ON for 1 second upon
PIR detection
RED Behind PIR Lens
Blinking RED: Device in Bluetooth
reset; continues until reset is
complete then stops
BLUE Behind PIR Lens Blinking BLUE LED: Device BLE in
Pairing Mode
BLUE / RED Behind PIR Lens Alternating BLUE/RED: Device in
Installation/Test Mode
GREEN Behind PIR Lens
and Locator
GREEN light behind PIR lens /
Locator LED blinking according to
Menu Mode: Device is in Manual
Configuration mode, number of LED
blinks shows which mode device is in
GREEN ALL Blinking GREEN LEDs indicates
device is in identify mode
GREEN / BLUE Behind PIR Lens
Alternating GREEN/BLUE during
1 minute Daylighting Hold-Off
Calibration
GREEN / BLUE Behind PIR Lens
GREEN/BLUE blinks for 2 seconds
every 30 seconds when Daylighting
is active
Locator Light
Top Button
Bottom Button
Statement Caution
Changes or modifications not expressly approved by Leviton Manufacturing Co., could void the user’s authority to operate the equipment.
FCC & IC COMPLIANCE STATEMENT:
This device complies with Part 15 of the FCC Rules and ISED License-exempt RSS standard(s).
This Class B digital apparatus complies with Canadian CAN ICES-3(B)/NMB-3(B)
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation. Changes or modifications not ex-pressly approved by Leviton could void the user’s authority to operate the equipment.
These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF EXPOSURE AND CO-LOCATION:
To comply with FCC OET Bulletin 65 and ISED RF exposure limits for general population / uncontrolled exposure this device should be installed and operated with a minimum
distance of 7.9 inches (20 cm) between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
Trademark Disclaimer
The Leviton logo and Decora are registered trademarks of Leviton Manufacturing Co., Inc. Google Play and Android are trademarks of Google, LLC. The Apple App Store is a
registered trademark of Apple, Inc. Bluetooth™ is a trademark of Bluetooth™ SIG, Inc. Use herein of other third party trademarks, service marks, trade names, brand names
and/or product names are for informational purposes only, are/may be the trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or
endorsement. No part of this document may be reproduced, transmitted or transcribed without the express written permission of Leviton Manufacturing Co., Inc.
• If sensor does not trigger when entering the room or space, increase the sensitivity
level of the sensor and/or check the daylighting settings (increase the
daylighting level).
• If the lights constantly stay ON even when room is unoccupied:
- Check the Time Out setting and confirm set to desired time.
- Try lowering the sensor sensitivity; if problem persists, try lowering again.
- Check for reflected heat/motion as sensor may be seeing motion through
a window.
- Check for adjacent HVAC and/or heater ducts.
PUSH-BUTTON: ODS15-GD has a push-button switch that will toggle the lights ON
or OFF. When mode is set to Auto ON / Auto OFF, the lights will automatically turn
ON when occupancy is detected and will turn OFF automatically after occupancy is
no longer detected and the timeout has expired. If mode is set to Manual ON / Auto
OFF, the lights will only turn ON when the push-button switch is pressed; the lights
will turn OFF automatically after occupancy is no longer detected and the timeout
has expired. If the lights are ON, the lights can be turned OFF when the button is
pressed. The lights will stay OFF (regardless of motion detected) until the timeout
expires. After the timeout expires, the lights will turn ON when the next motion is
detected. This is useful for slide or film presentations.
NOTES:
• The Motion Indicator light will blink RED for 1 second each time motion is detected.
• In Manual ON mode, the button must be pressed to turn the lights ON. In the
absence of motion, the unit will time out and turn the lights OFF.
Operation
2. If the installer does not have access to a Bluetooth
enabled Android or iOS device, popular preset product
configuration can also be made using simple push
button commands:
a. If wall plate is attached, remove first. With the
wallplate removed, pinch sides of sensor near
bottom tabs to release front cover of sensor.
Troubleshooting