manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leviton
  6. •
  7. Dimmer
  8. •
  9. Leviton VZI06-1L User manual

Leviton VZI06-1L User manual

Single Pole (One location) or 3-Way (Multi-location)
Incandescent Dimmer
Cat. No. VZI
Ø
6-1L, 600W (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-VZI06-02C
Preparing and connecting wires:
This dimmer can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to terminal screw marked “BK”.
• Load wall box wire to terminal screw marked “RD”.
•
Dimmer terminal screw marked “YL/RD” should have Red
insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
“YL/RD”, use electrical tape to cover.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Load
Dimmer
BK
Black
White
RD
Green
Ground
Line
120VAC, 60Hz
YL/RD
Use Terminal for 3-Way or
More Applications Only.
For Single-Pole Applications,
Do Not Remove This Label.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Coordinating Remote (no LEDs) Application, go to
Step 4b.
• For 3-Way Matching Remote (with LEDs) Application, go to
Step 4c.
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
• Use with incandescent or 120V halogen fixtures only.
• Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will
turn the light on at the brightness level selected at the dimmer.
WARNINGS AND CAUTIONS:
• Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2”.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Step 4a cont’d
IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both the
dimmer wall box and remote wall box.
Strip Gage
(measure bare wire
here or use gage on
back of the dimmer)
5/8”
(1.6 cm)
Cut
(if necessary)
Bl
Back Wire
(either hole may be used)
Back wire openings use #14-12
AWG solid copper wire only.
Side Wire Connection
Side wire terminals accept #14
AWG solid copper wire only.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
•Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BK”.
• First Traveler wall box wire to terminal screw marked “RD” (note
wire color). This traveler from the dimmer must go to the terminal
screw on the remote marked “RD”.
• Remove Red insulating label from terminal screw marked “YL/RD”.
• Second Traveler wall box wire to terminal screw marked “YL/RD”
(note wire color). This traveler from the dimmer must go to the
terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “BK”.
• First Traveler wall box wire (note color as above) to terminal
screw marked “RD”. This traveler from the remote must go to the
terminal screw on the dimmer marked “RD”.
• Second Traveler wall box wire (note color as above) to terminal
screw marked “YL/RD”. This traveler from the remote must go to
the terminal screw on the dimmer marked “YL/RD”.
• Remote terminal screw marked “WH” should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
“WH”, use electrical tape to cover.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD YL/RD
RD
WH
RD
BK
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Push in side
at tab to release
Line up tabs and
press in side to attach
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Tools needed to install your Dimmer
Installing Dimmer by itself or with other devices
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Changing the color of your Dimmer:
If a color change kit is provided with your device and a color change
is desired, proceed with the following step. Otherwise, proceed to
“Installing Dimmer by itself or with other devices” section. To change
color of your device proceed as follows:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Refer to the chart for maximum load per dimmer.
Cat. No.
VZI
Ø
6
Single
600W
Two Devices
500W
More than 2
Devices
400W
√
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
2
4
1
5
3
3-Way
1. Line or Load (See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs
installation, the First Traveler becomes
Line Hot.
2
4
3
1
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Step 2 Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble any
of these configurations, consult a qualified electrician.
Step 3
BK
YL/RD RD
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal Label:
Use Terminal for 3-Way or More Applications Only.
For Single-Pole Applications, Do Not Remove This
Label.
4
3
2
1
Single-Pole Wiring Application:
Step 4a
BK
YL/RD RD
BK
YL/RD RD
4
3
2
1
5
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red(RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Coordinating Remote
2
4
3
5
1
Dimmer
(Coordinating Dimming Remote Depicted)
3-Way Wiring with Coordinating
Dimming or Switching Remote (no LEDs)
Application:
Step 4b
Step 4b cont’d
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of
purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused,
or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is
limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Dimmer
Remote (with LEDs)
YL/RD YL/RD
RD
WH BK BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral
wire to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to dimmer terminal screw
marked “BK”.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked “YL/RD” (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked
“YL/RD”.
• Line Neutral wall box to remote terminal screw marked “WH”.
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to dimmer terminal screw marked “RD”.
• First Traveler Line Hot to dimmer terminal screw marked “BK”.
• Remove Red insulating label from terminal screw marked
“YL/RD”.
•
Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked “YL/RD”. This traveler from the dimmer
must go to the terminal screw on the remote marked “YL/RD”.
• Proceed to Step 5.
BK
YL/RD RD
BK
YL/RD RD
4
3
2
1
5
Additional
Neutral Wire
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Red (RD)
Matching Dimmer Remote Dimmer
4
3
5
WH
1
2
DI-000-VZI06-02C
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
•Position all wires to provide room in
outlet wall box for device.
•
Ensure that the word “TOP” is facing
up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON. If lights do not turn ON,
press the upper half of DIM/BRIGHT bar
until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full
bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar –
Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar –
Lights dim to desired level.
If you continue to hold the lower half of
the DIM/BRIGHT Bar, the lights will DIM
to minimum level and then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power is restored the lights will
return to the last setting before the power interruption.
LED Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
*default
** LED #1 is located at the top
Preset LED** Fade On Fade Off
1*1 Approx. 1.5s from full off Approx. 3s from full on
2 2 No Fade No Fade
3 3 No Fade Approx. 3s from full on
4 4 Approx. 0.5s from full off Approx. 3s from full on
5 5 Approx. 0.5s from full off Approx. 1.5s from full on
6 6 Approx. 1.5s from full off Approx. 5s from full on
7 7 Approx. 1.5s from full off Approx. 10s from full on
Fade Rate Presets
1
2
3
4
5
6
7
LED
Brightness
Display
Testing your Dimmer prior to mounting in
wall box:
Step 5 To Program:
NOTE: Have a flashlight handy if
this dimmer controls the only light
source in the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling
the bottom of the push pad until
it lifts completely out of the frame
and a click is heard and all LED’s
are OFF.
2. Press push pad back into frame
and hold push pad for 7 seconds
until the locator light and the top
LED (LED 1) starts blinking.
3. Upon releasing the push pad,
the locator light will continue
to blink once per second indicating the dimmer is in Mode 1,
Set Minimum Brightness mode. To change the current Minimum
Brightness level from 1-50%, use the DIM/BRIGHT Bar. This
setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level
mode. The locator light will blink twice per second. To change the
current Set Dim-Lock level from 1-100%, use the DIM/BRIGHT
Bar. If this feature is not desired, press and hold the lower half
of the DIM/BRIGHT Bar until no LED is lit. This setting will
automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator light will blink 3 times per second. To change the current
Fade Rate, use the DIM/BRIGHT Bar to move the LED to the
desired preset level. This setting will automatically be saved by
tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each
LED represents a preset level with LED 1 (Preset 1) located at the
top and LED 7 (Preset 7) located at the bottom. Refer to chart for
settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of
inactivity.
Mode Description Range Default
1 Set Min. Brightness 1-50% 25%
2 Set Dim-Lock Level 0-100%, 0=no lock 0
3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
Advanced Features Summary
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were
turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to one
of 7 different settings.
ADVANCED PROGRAMMING FEATURES
Gently lift bottom
of push pad out
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a click
is heard and all LED’s are OFF (refer to
Figure). This will cut power to the fixture to
replace the bulb. After servicing is complete,
push the push pad back for normal
operation.
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
OPERATION
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will turn
ON at brightness set on dimmer’s DIM/BRIGHT bar. The lighting can
be controlled from either the dimmer or the remote location.
Step 4c 3-Way Wiring with Matching Remote
(w/LEDs) Application:
Restore Power: Restore power at circuit breaker
or fuse.
Installation is complete.
Step 7
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE.
Step 6
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
This equipment has been tested and found to comply with the
limits for a Class B Digital Device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment OFF and ON, the
user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the
receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for
help.
FCC COMPLIANCE STATEMENT
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer
and/or remote.
• Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
• Intermittent dimmer operation
- Minimum load is under 40W.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.leviton.com
Covered by one or more US & Foreign
Patents and patents pending
Copyright©2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
TROUBLESHOOTING

Other Leviton Dimmer manuals

Leviton VZE04-1L User manual

Leviton

Leviton VZE04-1L User manual

Leviton Acenti ACX10-1L User manual

Leviton

Leviton Acenti ACX10-1L User manual

Leviton MRIDC User manual

Leviton

Leviton MRIDC User manual

Leviton ACI06-1L User manual

Leviton

Leviton ACI06-1L User manual

Leviton I 24 Manual

Leviton

Leviton I 24 Manual

Leviton Topaz 12 User manual

Leviton

Leviton Topaz 12 User manual

Leviton NSI DS8 Operating instructions

Leviton

Leviton NSI DS8 Operating instructions

Leviton Decora Smart DWVAA User manual

Leviton

Leviton Decora Smart DWVAA User manual

Leviton decora IP710-LF User manual

Leviton

Leviton decora IP710-LF User manual

Leviton Decora Smart DN6HD User manual

Leviton

Leviton Decora Smart DN6HD User manual

Leviton Topaz 12 Operating and safety instructions

Leviton

Leviton Topaz 12 Operating and safety instructions

Leviton DDS3600R Operating instructions

Leviton

Leviton DDS3600R Operating instructions

Leviton Acenti ACH08 User manual

Leviton

Leviton Acenti ACH08 User manual

Leviton lumina 0-10VDC RF User manual

Leviton

Leviton lumina 0-10VDC RF User manual

Leviton VZX10-1L User manual

Leviton

Leviton VZX10-1L User manual

Leviton RZP03-1LW Installation instructions

Leviton

Leviton RZP03-1LW Installation instructions

Leviton Acenti ACE04-1L User manual

Leviton

Leviton Acenti ACE04-1L User manual

Leviton Decora Mural MLI06-1 User manual

Leviton

Leviton Decora Mural MLI06-1 User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton Decora Mural MCM06-1 User manual

Leviton

Leviton Decora Mural MCM06-1 User manual

Leviton 6615-P User manual

Leviton

Leviton 6615-P User manual

Leviton LumaCan DRDDP User manual

Leviton

Leviton LumaCan DRDDP User manual

Leviton Vizia RZI6-1L User manual

Leviton

Leviton Vizia RZI6-1L User manual

Leviton Vizia RF RZM10-1L User manual

Leviton

Leviton Vizia RF RZM10-1L User manual

Popular Dimmer manuals by other brands

Acclaim Lighting X-Dimmer-3 PRO User instructions

Acclaim Lighting

Acclaim Lighting X-Dimmer-3 PRO User instructions

SG DALI LEDDim manual

SG

SG DALI LEDDim manual

urmet domus Yokis MTV500ERP manual

urmet domus

urmet domus Yokis MTV500ERP manual

PEHA PHC Universal dimmer 1000W Installation and operating manual

PEHA

PEHA PHC Universal dimmer 1000W Installation and operating manual

Philips Optio OPT22000F installation instructions

Philips

Philips Optio OPT22000F installation instructions

AMX RDM-MDM Wiring diagrams

AMX

AMX RDM-MDM Wiring diagrams

LSC DP-610 user manual

LSC

LSC DP-610 user manual

Makel RC operating instructions

Makel

Makel RC operating instructions

AMX RDM-3DC installation guide

AMX

AMX RDM-3DC installation guide

MOOSE D1216 user manual

MOOSE

MOOSE D1216 user manual

Quick HDIM300 Manual of use and maintenance

Quick

Quick HDIM300 Manual of use and maintenance

Sygonix 2348945 operating instructions

Sygonix

Sygonix 2348945 operating instructions

LEGRAND Excel Life EM450UP quick start guide

LEGRAND

LEGRAND Excel Life EM450UP quick start guide

SKYDANCE KL instructions

SKYDANCE

SKYDANCE KL instructions

Acclaim Lighting AL-Dimmer-1PRO User instructions

Acclaim Lighting

Acclaim Lighting AL-Dimmer-1PRO User instructions

AMX RDM-2DC Specifications

AMX

AMX RDM-2DC Specifications

Lightronics AS-40 owner's manual

Lightronics

Lightronics AS-40 owner's manual

Nicols DP 405 instruction manual

Nicols

Nicols DP 405 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.