FEATURES
•Leviton's Decora® Style design • Scene Capabilities
•Soft fade ON/OFF • Power interruption - load returns to existing state
•Minimum Brightness Adjustment • ON/OFF LED indicates status of load
•Brightness Level Display • Color conversion available
•Double Tap functions
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device must not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL
CODES AND REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A
QUALIFIED ELECTRICIAN.
WARNING: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND
OTHER EQUIPMENT, USE ONLY WITH THE APPROPRIATE ADVANCE MARK X™ 120V ELECTRONIC
DIMMING BALLASTS FOR CONTROLLING THE SPECIFIC FLUORESCENT LAMPS.
OTHER CAUTIONS:
1. BOTH LIGHTING FIXTURE AND DIMMER MUST BE GROUNDED.
2. DISCONNECT POWER WHEN SERVICING OR CHANGING LAMPS.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off (refer to Figure 1). The side sections dissipate heat, so removing
them requires a derating of the dimmer's capacity (refer to chart).
MAXIMUM BULB WATTAGE:
Advance Mark X™ dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency
of the Advance Mark X™ ballast. Table 1 shows the maximum number of ballasts that can be connected to a
single dimmer for different Advance Mark X™ ballasts. Also note the table shows maximum ballasts for multi-
gang installations.
NOTE: For multiple ballasts on one dimmer, use only the same model ballast.
TO INSTALL:
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch or dimmer, if applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
4. Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and,
with circuit conductors, push firmly into appropriate wire connector (see chart for allowable wire
connector and number of conductor combinations). Screw connectors on clockwise making sure that no
bare conductor shows below the wire connectors. Secure each connector with electrical tape.
5. Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
screws supplied.
6. Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).
NOTE: This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the
dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:
7. The brightness adjustment is located on the side of the dimmer (refer to Figure 1). Using a small, insulated
screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker.
To decrease the minimum brightness, press the lower half of the rocker.
8. Release the rocker. Release adjustment switch and minimum brightness is set. Check for
proper operation by tapping the lower half of the rocker so the lights turn OFF, then
tapping the upper half of the rocker so the lights turn ON.
The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.
9. Attach Decora®wallplate (not included). INSTALLATION IS COMPLETE.
NOTE: On the lower left corner of the switch frame, there is an air-gap switch. When
servicing a controlled fixture, pull lever out (OFF position). This will cut the power to the
fixture. After servicing is complete, push the lever in (ON position) to restore power. The lever
must be pushed in all the way (ON position) for normal operation.
DI-00X-MCX10-00A
Scene Capable Dimmer
120VAC, 60Hz
Fluorescent Only
Cat. No. MCX1
Ø
-1, 1000VA
(w/brightness level display)
Total minimum wattage
must exceed 60VA
For use w/ Advance
Mark X™ Dimming Ballasts
INSTALLATION INSTRUCTIONS
DI-00X-MCX10-00A
C O L L E C T I O N B Y L E V I T O N
Upper
Rocker
Air Gap
Switch ON/OFF
LED
Lower
Rocker
Minimum Brightness
Adjustment Switch
Brightness Level
Display
Mounting Strap
Side Sections
Figure 1 – Dimmer Functions
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTYAND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not
for the benefit of anyone else that this product at the time of its
sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase
date. Leviton’s only obligation is to correct such defects by repair
or replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point
Claire, (Quebec), Canada H9R 1E9). This warranty excludes
and there is disclaimed liability for labor for removal of this product
or reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
purpose, but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty,
whether based on contract, tort or otherwise.
Two More than
Cat. No. Single Gang 2 Gang
MCX1
Ø
-1 1000VA 800VA 700VA
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/G24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
REZ-1T32
REZ-1T32
REZ-1T42
REZ-2Q26
REZ-132
REZ-2S32
REZ-3S32
REZ-132
REZ-2S32
REZ-3S32
REZ-1TTS40
REZ-2TTS40
Advance
Mark X™
Part No. Lamps
Max. # Ballasts/Dimmer for Multi-gang
Two
Ganged
32
26
20
17
32
17
11
28
14
9
25
12
26
21
16
14
26
13
9
22
11
8
20
10
More than
2 Gang
22
18
14
12
22
12
8
19
10
7
17
9
Single
Gang
TABLE 1
Cat. No. MCX1
Ø
-1, 120V – For use with
Advance Mark X™ 120V Dimming Ballasts
WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20
2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22
DI-00X-MCX10-00A 10/4/02, 10:28 AM1
COLOR CONVERSION PROCEDURE
The color of this device can be changed to suit your interior design requirements. Simply obtain a color
conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that
wallplate must be removed).
1. Select the color of the face you desire.
2. The frame has snaps on its sides. Using a small screwdriver, gently remove the frame from the strap (refer to Figure 2).
3. Take the new frame and position it properly to the strap. Notice that the frame has a cut-out for the air-gap switch
lever. Line up the plastic snaps with the square holes in the strap. Insert the snaps on one side of the frame into the
strap.
4. Firmly press sideways and down to slip the other snaps into place. The frame snaps in with a audible click.
Ensure that all four snaps are secure. Replace Decora®wallplate. The color conversion is complete.
TO PROGRAM
Programming scenes occurs at the Scene Controller for this dimmer. If programming is required, refer to Scene
Controller’s instruction sheet.
TO OPERATE
ON: Tap the upper half of the rocker. The lights will brighten to the last set light level.
OFF: Tap the lower half of the rocker. The lights will dim to OFF.
BRIGHTEN: Press and hold the upper half of the rocker to the desired light level.
FULL BRIGHT: If the lights are OFF, double tap the upper half of the rocker. The lights will turn ON FULLBRIGHT.
If the lights are ON, tap the upper half of the rocker once. The lights will turn ON FULL BRIGHT.
The previous light level will remain in memory upon next ON operation (see above).
FAST OFF: Double tap the bottom half of the rocker. The lights will immediately turn OFF.
DIM: Press and hold the lower half of the rocker to the desired level.
BRIGHTNESS LEVEL DISPLAY:
Indicates the level of brightness when the lights are ON. Indicates the previous level of brightness when the lights are
OFF (refer to Figure 1).
NOTE: To alert you that there is power to the dimmer when the load is OFF, the ON/OFF LED remains ON. To
alert you that the load is ON, the ON/OFF LED remains OFF.
NOTE: If lights are OFF, regardless if you tap or press and hold the upper half of the rocker, the lights will go to
last set light level.
NOTE: If a power interruption should occur while the device is ON, the light load will return to its previous light level
when power is restored within 10 seconds.
TROUBLESHOOTING
•Light does not turn ON and ON/OFF LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp switch is OFF, if applicable.
- Ballast has failed.
- Ballast is not connected to line Neutral.
- Air gap switch is open.
•Dimmer does not operate
- Dimmer BLACK wire miswired to ballast and Dimmer BLUE wire miswired to LINE Hot.
•Light turns ON and Dimmer works, but Controller does not work
- There are no connections from Controller to Dimmer (YELLOW wire).
- Controller is miswired.
•Lights Flickering
- Lamp has a bad connection.
- Lamp power is less than 60VA.
Hot (Black)
Neutral (White)
Scene Capable
Dimmer
Blue
White
Black
Yellow Yellow
White
Black
Line
120VAC, 60Hz
Scene Controller
Green
Ground
Black
White
Ballast
Red
Blue
Yellow
To Lamps
Primary
Side
Hot (Black)
Neutral (White)
Load
Scene Capable Dimmer
(Incandescent)
Scene Capable Dimmer
(Mark X)
Blue
Blue
WhiteWhite
Black
Black Black
Yellow
Yellow
Yellow Black
White
Black
White
Line
120VAC, 60Hz
Scene
Controller
Scene
Controller
Green
Ground
Green
Ground
Black
White
To Lamps
Primary
Side
Ballast
Red
Blue
Yellow
Wiring Diagram 1 – Two Location Control Application
Wiring Diagram 2 – Scene Dimming: Fluorescent and Line Voltage with
Multiple Scene Controllers and Scene Dimmers
Wiring Diagram 3 – Scene Dimming: Fluorescent and Line Voltage with
Multiple Scene Controllers and Dimmer on Two Circuits
Scene
Dimmer
(Mark X)
Scene
Dimmer
(Incandescent)
Scene
Controller
17100-2WY
REPEATER
2-Way
Scene
Controller
Black
120VAC, 60Hz
Black Red
Neutral B
Neutral A
Yellow
Yellow
Black Yellow
Blue
White
White
Gray
Yellow/Red
Line B
Line A
Load
White White
Yellow
Black
Black Yellow
Circuit A Circuit B
Green
Ground Green
Ground
Black
White
To Lamps
Primary
Side
Ballast
Red
Blue
Yellow
Blue
DI-00X-MCX10-00A
Frame
Strap
Air-Gap
Switch
Snaps
Push in 2 Locations ON/OFF
LED
Brightness Level Display
Figure 2 - Color Conversion
DI-00X-MCX10-00A 10/4/02, 10:28 AM2

Other Leviton Dimmer manuals

Leviton lumina 0-10VDC RF User manual

Leviton

Leviton lumina 0-10VDC RF User manual

Leviton 6628 User manual

Leviton

Leviton 6628 User manual

Leviton 600 Series Owner's manual

Leviton

Leviton 600 Series Owner's manual

Leviton 6631-L User manual

Leviton

Leviton 6631-L User manual

Leviton DDS5300 Operating instructions

Leviton

Leviton DDS5300 Operating instructions

Leviton ACM06-1L User manual

Leviton

Leviton ACM06-1L User manual

Leviton RZP15 User manual

Leviton

Leviton RZP15 User manual

Leviton Vizia RF RZP03-1LW User manual

Leviton

Leviton Vizia RF RZP03-1LW User manual

Leviton Decora Illumatech IPX06-1 User manual

Leviton

Leviton Decora Illumatech IPX06-1 User manual

Leviton Topaz 12 Operating and safety instructions

Leviton

Leviton Topaz 12 Operating and safety instructions

Leviton NSI DS8 Operating instructions

Leviton

Leviton NSI DS8 Operating instructions

Leviton Toggle Touch TGM10-1L User manual

Leviton

Leviton Toggle Touch TGM10-1L User manual

Leviton Decora Mural MDI06-1 User manual

Leviton

Leviton Decora Mural MDI06-1 User manual

Leviton VZX12-7L User manual

Leviton

Leviton VZX12-7L User manual

Leviton UNIV User manual

Leviton

Leviton UNIV User manual

Leviton Decora HCM10-1DW Installation instructions

Leviton

Leviton Decora HCM10-1DW Installation instructions

Leviton VZH08-1L User manual

Leviton

Leviton VZH08-1L User manual

Leviton DDS6000 User manual

Leviton

Leviton DDS6000 User manual

Leviton Vizia RF RZM10-1L User manual

Leviton

Leviton Vizia RF RZM10-1L User manual

Leviton a-2000 User manual

Leviton

Leviton a-2000 User manual

Leviton DMX-512 Installation guide

Leviton

Leviton DMX-512 Installation guide

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton DDS 6000+ User manual

Leviton

Leviton DDS 6000+ User manual

Leviton i Series e User manual

Leviton

Leviton i Series e User manual

Popular Dimmer manuals by other brands

Westcott 7580 user manual

Westcott

Westcott 7580 user manual

AMX RDM-MDM Wiring diagrams

AMX

AMX RDM-MDM Wiring diagrams

SMG Powerlight 612 user manual

SMG

SMG Powerlight 612 user manual

DALCNET SLIM 2CV CASAMBI Device manual

DALCNET

DALCNET SLIM 2CV CASAMBI Device manual

Velleman WRS Series quick start guide

Velleman

Velleman WRS Series quick start guide

Lightronics RD-122 owner's manual

Lightronics

Lightronics RD-122 owner's manual

preussen DimME KNX product manual

preussen

preussen DimME KNX product manual

Behringer EUROLIGHT LD6230 user manual

Behringer

Behringer EUROLIGHT LD6230 user manual

SRS Light Design DDP 610 PG instruction manual

SRS Light Design

SRS Light Design DDP 610 PG instruction manual

Jung FUSD 1253 quick start guide

Jung

Jung FUSD 1253 quick start guide

Lapetek SMART 300 Assembling instructions

Lapetek

Lapetek SMART 300 Assembling instructions

GE Z-Wave 45606 manual

GE

GE Z-Wave 45606 manual

NSI ND 4600 Operation manual

NSI

NSI ND 4600 Operation manual

ETC SMARTRACK user manual

ETC

ETC SMARTRACK user manual

ATX AL-WS-DR1-PIR manual

ATX

ATX AL-WS-DR1-PIR manual

hager WBMDUPB quick start guide

hager

hager WBMDUPB quick start guide

Green image GC-2830CDMX-US quick start guide

Green image

Green image GC-2830CDMX-US quick start guide

Crestron CLX-1DELV4 Specification sheet

Crestron

Crestron CLX-1DELV4 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.