FEATURES
•Leviton's Decora® Style design • Double Tap functions
•Soft fade ON/OFF • Power interruption – load returns to existing state
•Minimum Brightness Adjustment • ON/OFF LED indicates status of load
•Brightness Level Display • Color conversion available
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING: TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE,
FLUORESCENT LIGHTING, OR A MOTOR - OR TRANSFORMER - OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.
CAUTION (For Incandescent Only): USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.
CAUTION (For Magnetic Low-Voltage Only):
1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE
DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE TRANSFORMERS.
2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL,
WITH ALL LAMPS INOPERATIVE, EXCESS CURRENT MAY FLOW THROUGH THE
TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE TO
OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL
PROTECTION OR A FUSE AT THE PRIMARY WINDINGS.
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. FOR REMOTE OPERATION, USE THE
LEVITON MULTI-REMOTETM, CAT. NO. MS
ØØ
R-1. DO NOT USE A 3-WAY SWITCH.
2. DISCONNECT POWER WHEN SERVICING OR CHANGING BULBS.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off (refer to Figure 1). The side sections dissipate heat, so removing
them requires a derating of the dimmer's capacity (refer to chart).
MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage Only):
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of
the transformer in the low-voltage lighting system. Transformer efficiencies will vary from different manufacturers;
consider 75% efficient as average. Use the chart to determine maximum bulb wattage for typical transformer
efficiency ratings.
TO INSTALL:
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch or dimmer, if applicable.
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
4. Connect lead wires per appropriate WIRING DIAGRAM as follows: WARNING: CONNECT A MAGNETIC
LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-
VOLTAGE TRANSFORMER. Twist strands of each lead tightly and, with circuit conductors, push firmly into
appropriate wire connector (see chart for allowable wire connector and number of conductor
combinations). Screw connectors on clockwise making sure that no bare conductor shows below the wire
connectors. Secure each connector with electrical tape.
NOTE: For single pole applications, cap YELLOW lead with an appropriate size wire connector. Secure
connector with electrical tape.
5. Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
screws supplied.
6. Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).
NOTE: This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the
dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
Yor k 11362-2591. This warranty excludes and there is
disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
Single Pole (One location) or
3-Way (Multi-location)
120VAC, 60Hz
Incandescent
Cat. No. MDI
Ø
6-1, 600W
(w/brightness level display)
Cat. No. MDI1
Ø
-1, 1000W
(w/brightness level display)
Magnetic Low-Voltage
Cat. No. MDM
Ø
6-1, 600VA
(w/brightness level display)
Cat. No. MDM1
Ø
-1, 1000VA
(w/brightness level display)
Total minimum wattage must
exceed 40W and 40VA
For use w/ Cat. No. MS
ØØ
R-1 Multi-Remote™
INSTALLATION INSTRUCTIONS
PK-93079-10-00-0A
C O L L E C T I O N B Y L E V I T O N
Two More than
Rating Single Gang 2 Gang
600VA 450W 375W 300W
1000VA 750W 600W 525W
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Two More than
Cat. No. Single Gang 2 Gang
MDI
Ø
6-1 600W 500W 400W
MDI1
Ø
-1 1000W 800W 700W
MDM
Ø
6-1 600VA 500VA 400VA
MDM1
Ø
-1 1000VA 800VA 700VA
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
PK-93079-10-00-0A
Upper
Rocker
Air Gap
Switch ON/OFF
LED
Lower
Rocker
Minimum Brightness
Adjustment Switch
Brightness Level
Display
Mounting Strap
Side Sections
Figure 1 – Dimmer Functions
WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20
2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22
PK-93079-10-00-0A 10/16/02, 4:45 PM1
Hot (Black)
Neutral (White)
Load
Mural
Dimmer
Blue
Yellow
Green
Ground
Black
White
Black
Line
120VAC, 60Hz
Cap with
Wire Connector
(OR PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
}
Wiring Diagram 1 – Single Control Application
Hot (Black)
Neutral (White)
Load
Mural
Dimmer
Blue Blue
Yellow Yellow
Green
Ground
Green
Ground
Black
White
Black
Line
120VAC, 60Hz
Multi-Remote
MS
ØØ
R-1
(OR PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
}
Wiring Diagram 2 – Two Location Control Application
Hot (Black)
Neutral (White)
Load
Mural
Dimmer
Blue Blue
Blue
Yellow Yellow Yellow
Green
Ground
Green
Ground
Green
Ground
Black
White
Black
Line
120VAC, 60Hz
(OR PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
}
Multi-Remote
MS
ØØ
R-1
Multi-Remote
MS
ØØ
R-1
Wiring Diagram 3 – Three Location Control Application
7. The brightness adjustment is located on the side of the dimmer (refer to Figure 1). Using a small, insulated
screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker. To decrease the minimum brightness, press the lower half of the rocker.
8. Release the rocker. Release adjustment switch and minimum brightness is set. Check for proper operation
by tapping the lower half of the rocker so the lights turn OFF, then tapping the upper half of the rocker so the
lights turn ON. The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.
9. Attach Decora®wallplate (not included). INSTALLATION IS COMPLETE.
NOTE: On the lower left corner of the switch plate, there is an air-gap switch. When servicing a controlled
fixture, pull lever out (OFF position). This will cut the power to the fixture. After servicing is complete, push the
lever in (ON position) to restore power. The lever must be pushed in all the way (ON position) for normal
operation.
COLOR CONVERSION PROCEDURE
The color of this device can be changed to suit your interior design requirements. Simply obtain a color
conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that
wallplate must be removed).
1. Select the color of the face you desire.
2. The frame has snaps on its sides. Using a small screwdriver, gently remove the frame from the strap (refer
to Figure 2).
3. Take the new frame and position it properly to the strap. Notice that the frame has a cut-out for the air-gap
switch lever. Line up the plastic snaps with the square holes in the strap. Insert the snaps on one side of the
frame into the strap.
4. Firmly press sideways and down to slip the other snaps into place. The frame snaps in with a audible click.
Ensure that all four snaps are secure. Replace Decora®wallplate. The color conversion is complete.
TO OPERATE:
ON: Tap the upper half of the rocker. The lights will brighten to the last set light level.
OFF: Tap the lower half of the rocker. The lights will dim to OFF.
BRIGHTEN: Press and hold the upper half of the rocker to the desired light level.
FULL BRIGHT: If the lights are OFF, double tap the upper half of the rocker. The lights will turn ON FULL
BRIGHT.
If the lights are ON, tap the upper half of the rocker once. The lights will turn ON FULL
BRIGHT.
The previous light level will remain in memory upon next ON operation (see above).
FAST OFF: Double tap the bottom half of the rocker. The lights will immediately turn OFF.
DIM: Press and hold the lower half of the rocker to the desired level.
BRIGHTNESS LEVEL DISPLAY:
Indicates the level of brightness when the lights are ON. Indicates the previous level of brightness when the lights are
OFF (refer to Figure 1).
NOTE: To alert you that there is power to the dimmer when the load is OFF, the ON/OFF LED remains ON. To
alert you that the load is ON, the ON/OFF LED remains OFF.
NOTE: If lights are OFF, regardless if you tap or press and hold the upper half of the rocker, the lights will go to
last set light level.
NOTE: If a power interruption should occur while the device is ON, the light load will return to its previous light level
when power is restored within 10 seconds.
TROUBLESHOOTING
•Light does not turn ON and ON/OFF LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp is not connected to line Neutral.
- Air gap switch is open.
•Dimmer does not operate
- Dimmer BLACK wire miswired to lamp and Dimmer BLUE wire miswired to LINE Hot.
•Light turns ON and Dimmer works, but Multi-RemoteTM does not work
- There are no connections from Multi-RemoteTM to Dimmer.
- Multi-RemoteTM miswired to Dimmer.
•Lights Flickering
- Lamp has a bad connection.
- Lamp power is less than 40W or 40VA.
Frame
Strap
Air-Gap
Switch
Snaps
Push in 2 Locations ON/OFF
LED
Brightness Level Display
(Cat. Nos. MDI
Ø
6-1, MDI1
Ø
-1, MDM
Ø
6-1 & MDM1
Ø
-1 ONLY)
Figure 2 – Color Conversion
PK-93079-10-00-0A
PK-93079-10-00-0A 10/16/02, 4:45 PM2

This manual suits for next models

3

Other Leviton Dimmer manuals

Leviton Vizia RF RZI10-1L User manual

Leviton

Leviton Vizia RF RZI10-1L User manual

Leviton ACM06-1L User manual

Leviton

Leviton ACM06-1L User manual

Leviton VZX12-7L User manual

Leviton

Leviton VZX12-7L User manual

Leviton Toggle Touch TGM10-1L User manual

Leviton

Leviton Toggle Touch TGM10-1L User manual

Leviton VZM10-1L User manual

Leviton

Leviton VZM10-1L User manual

Leviton Topaz 24 Operating and safety instructions

Leviton

Leviton Topaz 24 Operating and safety instructions

Leviton ACM10-1L User manual

Leviton

Leviton ACM10-1L User manual

Leviton Decora Illumatech IPI06-1L User manual

Leviton

Leviton Decora Illumatech IPI06-1L User manual

Leviton RZCZ1 User manual

Leviton

Leviton RZCZ1 User manual

Leviton I 24 Manual

Leviton

Leviton I 24 Manual

Leviton Decora True Touch TTM10-1 User manual

Leviton

Leviton Decora True Touch TTM10-1 User manual

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton

Leviton Decora Multi-Remote MSE0R-1 User manual

Leviton DDS5300 Operating instructions

Leviton

Leviton DDS5300 Operating instructions

Leviton Vizia RZI6-1L User manual

Leviton

Leviton Vizia RZI6-1L User manual

Leviton VZH08-1L User manual

Leviton

Leviton VZH08-1L User manual

Leviton DDS 6000+ User manual

Leviton

Leviton DDS 6000+ User manual

Leviton DDS8800 Operating instructions

Leviton

Leviton DDS8800 Operating instructions

Leviton lumina 0-10VDC RF User manual

Leviton

Leviton lumina 0-10VDC RF User manual

Leviton D4DMX User manual

Leviton

Leviton D4DMX User manual

Leviton Vizia RF RZI06-1L User manual

Leviton

Leviton Vizia RF RZI06-1L User manual

Leviton Decora Smart DG6HD User manual

Leviton

Leviton Decora Smart DG6HD User manual

Leviton decora smart DZ1KD Operation and maintenance manual

Leviton

Leviton decora smart DZ1KD Operation and maintenance manual

Leviton Decora Mural MDE03-1 User manual

Leviton

Leviton Decora Mural MDE03-1 User manual

Leviton Acenti ACE04-1L User manual

Leviton

Leviton Acenti ACE04-1L User manual

Popular Dimmer manuals by other brands

Acclaim Lighting X-Dimmer-3 PRO User instructions

Acclaim Lighting

Acclaim Lighting X-Dimmer-3 PRO User instructions

Gewiss CHORUSMART GW10673 quick start guide

Gewiss

Gewiss CHORUSMART GW10673 quick start guide

Z-Wave Domitech PA-100 manual

Z-Wave

Z-Wave Domitech PA-100 manual

Elko iNELS RFDEL-71B-SL manual

Elko

Elko iNELS RFDEL-71B-SL manual

AMX RDM-DC DC MODULE Installation sheet

AMX

AMX RDM-DC DC MODULE Installation sheet

PEHA PHC Universal dimmer 1000W Installation and operating manual

PEHA

PEHA PHC Universal dimmer 1000W Installation and operating manual

Hoftronic 4406547 user manual

Hoftronic

Hoftronic 4406547 user manual

IKEA tradfri manual

IKEA

IKEA tradfri manual

ETC Unison Echo Forward-Phase Dimmer-Gen 2 installation guide

ETC

ETC Unison Echo Forward-Phase Dimmer-Gen 2 installation guide

ISYGLT UD-700-X2 Technical Data/Instruction Manual

ISYGLT

ISYGLT UD-700-X2 Technical Data/Instruction Manual

preussen DimME KNX product manual

preussen

preussen DimME KNX product manual

SSC-LUXon LUXARA 990070768 Assembly & operating instructions

SSC-LUXon

SSC-LUXon LUXARA 990070768 Assembly & operating instructions

INSTEON LampLinc 2457D2 quick start guide

INSTEON

INSTEON LampLinc 2457D2 quick start guide

Ekinex EK-GA1-TP Applications manual

Ekinex

Ekinex EK-GA1-TP Applications manual

EUCHIPS EUP12D-1H12V-0 user manual

EUCHIPS

EUCHIPS EUP12D-1H12V-0 user manual

RC4 Wireless DMX6dim-500 quick start guide

RC4 Wireless

RC4 Wireless DMX6dim-500 quick start guide

Ekinex EK-GD2-TP-1-HV Applications manual

Ekinex

Ekinex EK-GD2-TP-1-HV Applications manual

Sunricher SR-2304B manual

Sunricher

Sunricher SR-2304B manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.