LG LP-K3063ZA User manual

Floor Standing Air Conditioner
SVC MANUAL(Exploded View)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
MODEL : LP-K Series

Contents
Functions 3
Product Specifications 6
Dimensions 7
Refrigeration Cycle Diagram 7
Wiring Diagram 8
Operation Details 12
Installation of Indoor, Outdoor Unit 19
Test Running 30
3-way Valve 32
Cycle Troubleshooting Guide 38
Electronic Parts Troubleshooting Guide 39
Electronic Control Device 42
Schematic Diagram 43
Exploded View 44
- 2 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only

- 3 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Indoor Unit
Power Switch ON/OFF
Operation Mode Control
Indoor Fan Speed Control
Jet Cool
Energy Saving
Room Temperature control
Sensing Heat Exchanger Temperature
Soft Dry Operation Mode
Time Delay Safety Control
Fan Operation
AutoRestart
• Cooling, Heating, Soft Dry, Fan
• High, Low
• Speed Cooling operates super high fan speed in cooling mode
• Cooling Mode only
• Maintains the room temperature in accordance with the Setting Temp.
• Up: up to 30°C
• Down: down to 16°C
• Heat exchanger temperature sensor (Thermistor)
• Intermittent operation of fan at low speed.
• Restarting is inhibited for approx. 3 minutes.
• Used to circulate room air without cooling.
• The power comes on again after a power failure.
Functions

- 4 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
• Intermittent operation of fan at low speed.
• Used to circulate room air without cooling.
• OFF Timer (1, 2, 3,......7 hour)
• Speed cooling operates super high fan speed in cooling mode.
• Airflow direction Auto-swing and Manual Contol.
• Up: up to 30°C
• Down: down to 16°C
• High, Low
Remote Control
Operation ON/OFF
Cooling Operation Mode
Heating Operation Mode
Sot Dry Operation Mode
Fan Operation
Timer Control
Jet Cool
Energy Saving
Airflow Direction Control
Room Temperature Control
Indoor Fan speed control

- 5 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Outdoor Unit
Deice Control
Outdoor Fan Speed Control
Sensing Heat Exchanger Temperature
Sensing Discharge Pressure For Compressor
• De-ice PCB
• One speed
• Heat exchanger temperature sensor (Thermistor)
• Discharge pressure sensor (High Pressure Switch)

- 6 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Product Specifications
POWER SUPPLY Ø, V, Hz
COOLING CAPACITY Btu/hr
HEATING CAPACITY Btu/hr
(Incl. elec. Heater)
POWER INPUT COOLING W
HEATING W
RUNNING COOLING A
CURRENT HEATING A
MODEL
MAKER
TYPE
COMPRESSOR CAPACITY Btu/hr
INPUT (KW)
LRA A
NOISE LEVEL INDOOR dB(A)
OUTDOOR dB(A)
AIR INDOOR
CFM/CMM
CIRCULATION OUTDOOR
CFM/CMM
REFRIGERANT (R-22) OZ(kg)
HEAT INDOOR R/C/FPI
EXCHANGER OUTDOOR R/C/FPI
FAN INDOOR TYPE
OUTDOOR TYPE
ROOM TEMPERATURE CONTROL
WIDTH
INDOOR HEIGHT inch(mm)
DEPTH
WIDTH
OUTDOOR HEIGHT inch(mm)
DEPTH
NET WEIGHT INDOOR Ib(kg)
OUTDOOR Ib(kg)
CONNECTIONS LIQUID inch(mm)
GAS inch(mm)
1, 220-240, 50
27,800
27,800 + (2kw)
2,750
2,450
12.5
11.2
H23B33SABHA
BRISTOL
RECIPRO
28,300
2.76
76
48
58
670/19
2,225/63
88.1(2.5)
3/22/18
2/30/16
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
31.49(800)
12.59(320)
88.18(40)
143.2(65)
3/8"(Ø9.52)
5/8"(Ø15.88)
1, 220,60
27,800
27,800
3,400
3,200
16
14.5
AWG5532EXN
TELUMSEH
RECIPRO
31,500
3.3
90
48
58
670/19
2,225/63
82.9(2.35)
3/22/18
2/30/16
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
31.49(800)
12.59(320)
88.18(40)
143.2(65)
3/8"(Ø9.52)
5/8"(Ø15.88)
ITEMS UNIT
MODEL
LP-K3023HA/HL
LP-K3063ZA/ZL/HA/HB/HL/HM
LP-K30638A
D
I
M
E
N
S
I
O
N
S
• HEAT PUMP MODELS

- 7 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Product Specifications
• COOLING ONLY MODEL
POWER SUPPLY Ø, V, Hz
COOLING CAPACITY Btu/hr
HEATING CAPACITY Btu/hr
(Incl. elec. Heater)
POWER INPUT COOLING W
HEATING W
RUNNING COOLING A
CURRENT HEATING A
MODEL
MAKER
TYPE
COMPRESSOR CAPACITY Btu/hr
INPUT (KW)
LRA A
NOISE LEVEL INDOOR dB(A)
OUTDOOR dB(A)
AIR INDOOR
CFM/CMM
CIRCULATION OUTDOOR
CFM/CMM
REFRIGERANT (R-22) OZ(kg)
HEAT INDOOR R/C/FPI
EXCHANGER OUTDOOR R/C/FPI
FAN INDOOR TYPE
OUTDOOR TYPE
ROOM TEMPERATURE CONTROL
WIDTH
INDOOR HEIGHT inch(mm)
DEPTH
WIDTH
OUTDOOR HEIGHT inch(mm)
DEPTH
NET WEIGHT INDOOR Ib(kg)
OUTDOOR Ib(kg)
CONNECTIONS LIQUID inch(mm)
GAS inch(mm)
1, 220-240, 50
20,000
-
1,900
-
9
-
FX24QP12CA
LG
SCROLL
20,000
1.94
53
45
53
600/17
2,046/58
55(1.56)
2/22/18
2/24/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
25.78(655)
12.59(320)
88.18(40)
138.6(63)
1/4"(Ø6.35)
5/8"(Ø15.88)
1, 220,60
27,800
-
3,400
-
16
-
AWG5532EXN
TECUMSHE
RECIPRO
31,500
3.3
90
48
58
670/19
2,046/58
63.5(1.8)
3/22/18
2/24/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
25.78(655)
12.59(320)
88.18(40)
138.6(63)
3/8"(Ø9.52)
5/8"(Ø15.88)
1, 220-240, 50
27,800
-
2,850
-
13
-
H23B33SABHA
BRISTOL
RECIPRO
28,300
2.76
76
48
58
670/19
2,046/58
60.0(1.7)
3/22/18
2/24/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
25.78(655)
12.59(320)
88.18(40)
138.6(63)
3/8"(Ø9.52)
5/8"(Ø15.88)
1, 220,60
36,000
-
3,500
-
17
-
CR38K6-PFV-502
COPELAND
RECIPRO
38,200
3.52
102
52
62
741/21
2,225/63
84.6(2.4)
3/22/18
2/30/18
SIROCO
PROPELLER
MICOM CONTROL
19.68(500)
70.86(1800)
12.59(320)
34.25(870)
31.49(800)
12.59(320)
88.18(40)
147.7(67)
3/8"(Ø9.52)
5/8"(Ø15.88)
ITEMS UNIT
MODEL LP-K2063CA/CL/AA
LP-K3023CA/CL/
CM/AA
LP-K3063CA/CL/
CM/AA LP-K4023CA/CL/AA
D
I
M
E
N
S
I
O
N
S

- 8 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Dimensions
Indoor Unit
Air Outlet Vent
Remote Signal
Receptor
Air Inlet Vent
Air Intake Vent
(Rear)
Air Outlet
Vent
INDOOR UNIT OUTDOOR UNIT
HEAT
EXCHANGER HEAT
EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING
HEATING
REVERSING
VALVE
CHECK VALVE
CAPILLARY TUBE
CAPILLARY TUBE
BY PATH CAPILLARY TUBE
Outdoor Unit
Refrigeration Cycle Diagram

- 9 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Wiring Diagram
(1) LP-K3063ZA/ZL/HA/HL/HM/ZM, LP-K30638A
(2) LP-K3063ZA, LP-K30638A(Australia only)
WIRING DIAGRAM
OUTDOOR UNIT INDOOR UNIT
P/No.;3854A20172A
*
HIDDEN LINE(
- - - - - - -
) : FIELD WIRING
: OPTIONAL PARTS
NOTE
BL
BK
BR
RD
BLUE
BLACK
BROWN
RED
:
:
:
:
OR
WH
YL
GN/YL
ORANGE
WHITE
YELLOW
GREEN/YELLOW
:
:
:
:
RY-COMP
RY-S/HIGH
RY-HIGH
RY-MID
RY-LO
OR
WH
BK
BL
RD
RY-4WAY
RY-AIRC
RY-EH
RY-SYNC
CAPA
-CITOR
ZA,ZL
(HEATER
MODEL ONLY)
ZA,HA
(AIR CLEANER
MODEL ONLY)
FUSE
(250V/3.15L)
POWER
SUPPLY
HEATER
SM
DISPLAY PCB ASM
MAIN PCB ASM
FAN
MOTOR
68
24
01
DOOR S/W
BK
WH
RD
HVB
ASM
CN1
EVAP
TH
ROOM
TH
CN1
A/CL
UNIT
RY-BIMETAL
RY-BIMETAL
RY-BIMETAL
ELECTRIC
HEATER
RY-BIMETAL
RY-BIMETAL
POWER
SUPPLY
POWER
RELAY
T/B1 T/B2
SUMP HEATER
COMP
FAN
MOTOR
BR
BK
BR
BR
BL
BL
BL
BR
WH
OR
OR
RD BL
CSR
BK BK
BL
GN/YL
WH
BL
YL
HIGH PRESS
SWITCH
REVERSING
VALVE
BK
BK
CAPACITOR
CAPACITOR
YL
BK
BK
BK
BR
RD
BL
BL
GN/YL
YL
BR
BR
PIPE TH
L1
L3 L2
42
86
10
FUSE(250V,5A)
FUSE(250V,5A)
1(L)2(N)
1
2
3 546
3 546
4
3854AP2708X
OUTDOOR WIRING DIAGRAM
81
26
L3 L2 L1
0
R
C
S
561324
CAPACITOR
S/Capacitor
RD
BL
BR
BR
BK
SUMP
HEATER
BK
BL BL
BLRD
RD
BL
BL
BR
BK
BR
BL
BR
BK
HIGH PRESSURE
SWITCH
DEICER
PCB
BR
BL
POWER
INPUT TO INDOOR UNIT
TERMINAL
BLOCK
TERMINAL
BLOCK
FUSE 5A
FUSE 5A
POWER
RELAY
REVERSING
VALVE
COMP
CAPACITOR
YL OR
OR
BK
BK
BK
BK
WH YL
FAN
MOTOR
3
CN-
COMP
CN-
S/Capa
CN-POWER
4
3
4

- 10 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
(3) LP-K3063CA/CL/CM
(4) LP-K4023CA/CL/CM
INDOOR UNIT OUTDOOR UNIT
DISPLAY
PCB ASM
MAIN PCB ASM
RY-S/HIGH
RY-AIRC
BK
CN-DISP(1)
CN1
ROOM
TH
DOOR S/W
BK RD
BK
WH
RD
HVB
ASM
A/CL
UNIT
OR
BR YL
Cr
WH
BK
BL
RD
GN/YL
RY-COMP
RY-SYNC
(250V/3.15L)
SM
EVAP
TH
RY-HIGH
RY-MID
RY-LO
RD
GN/YL
BL
BR
FUSE
P/No.; 3854A20172B
CIRCUIT DIAGRAM
FAN
MOTER
COMP.
POWER
RELAY
POWER INPUT
HIDDEN LINE: FIELD WIRING
CAPACITOR
BR
BR
BL
BR
OR
BR
BL
BL
TERMINAL
BLOCK(6P)
1
F1
F2
234
GN/YL
56
BK
BL
BL
BK
BK
BR
CR
S
RD BL
OR YL
26
48
0
1
CAPACITOR
FAN
MOTOR
NOTE
BL
BK
BR
RD
OR
WH
YL
GN/YL:GREEN/YELLOW
: OPTIONAL PARTS
BLUE
BLACK
BROWN
RED
ORANGE
WHITE
YELLOW
:
:
:
:
:
:
:
CA
(AIR CLEANER
MODEL
ONLY)
3456
DISPLAY
PCB ASM
HVB
ASM
A/CL
ASM
RY-S/HIGH
OR
BR YL
GN/YL
Ci
WH
BK
BL
RD
RY-COMP
RY-SYNC
(250V 3.15A)
SM
Fan
Motor
CM
EVAP
TH
RY-HIGH
RY-MID
RY-LD
CN-DISP(1)
CN1 CN2
CN-DISP(2)
ROOM
TH
BK
WH
RD
BK
WH
RD
POWER SUPPLY
1ø, 220V, 60Hz
Tmo1
1 2 3 4 5 6
L1
T1
L2
T2
52C
B
A
RD
WH
BR
BK
BK
WH
WH
Tmo2
RD
RD
WH
BK
WH
GN/YL
RD
RD
BK
BK
63H
FUSE
250V
5 A
WH
R
S
C
WH
PTCR Cr
BK
FUSE
250V
5 A
FUSE
MAIN PCB ASM
BK
BK RD
BK
WH
RD
DOOR S/W
FMo
OR BK
BR
YL
Co
OR
INDOOR UNIT OUTDOOR UNIT
CIRCUIT DIAGRAM

- 11 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
(6) LP-K3023CA/CL/CM/AA
INDOOR UNIT OUTDOOR UNIT
DISPLAY
PCB ASM
MAIN PCB ASM
RY-S/HIGH
RY-AIRC
BK
CN-DISP(1)
CN1
ROOM
TH
DOOR S/W
BK RD
BK
WH
RD
HVB
ASM
A/CL
UNIT
OR
BR YL
Cr
WH
BK
BL
RD
GN/YL
RY-COMP
RY-REVERSING
VALVE
RY-SYNC
(250V/3.15L)
SM
EVAP
TH
RY-HIGH
RY-MID
RY-LO
RD
BL
GN/YL
BL
BR
FUSE
P/No.; 3854A20172C
CIRCUIT DIAGRAM
FAN
MOTER
COMP.
POWER
RELAY
POWER
INPUT
HIDDEN LINE: FIELD WIRING
CAPACITOR
BR
BL
BL
BR
BR
BL
BL
TERMINAL
BLOCK(6P)
1
F1
F2
23456
BR
BL
BK
WH
BK BKBK
YL
BK
BR
CR
S
RD BL
OR
OR
YL
26
48
0
1
CAPACITOR
FAN
MOTOR
NOTE
BL
BK
BR
RD
OR
WH
YL
GN/YL: GREEN/YELLOW
: OPTIONAL PARTS
BLUE
BLACK
BROWN
RED
ORANGE
WHITE
YELLOW
:
:
:
:
:
:
:
L1 L2 L3
HIGH PRESS
SWITCH
T/B2
REVERSING
VALVE
DEICER
P.C.B
OR
BK
HA
(AIR CLEANER
MODEL
ONLY)
3456
T/B1
INDOOR UNIT OUTDOOR UNIT
DISPLAY
PCB ASM
MAIN PCB ASM
RY-S/HIGH
RY-AIRC
BK
CN-DISP(1)
CN1 ROOM
TH
DOOR S/W
BK RD
BK
WH
RD
HVB
ASM
A/CL
UNIT
OR
BR YL
Cr
WH
BK
BL
RD
GN/YL
RY-COMP
RY-SYNC
(250V/3.15L)
SM
EVAP
TH
RY-HIGH
RY-MID
RY-LO
RD
GN/YL
BL
BR
FUSE
P/No.; 3854A20172D
CIRCUIT DIAGRAM
FAN
MOTER
COMP.
POWER
RELAY
POWER INPUT
HIDDEN LINE: FIELD WIRING
CAPACITOR
BR
BR
BL
BR
OR
BR
BL
BL
TERMINAL
BLOCK(6P)
1
F1
F2
234
GN/YL
56
BK
BL
BL
BK
BK
BR
CR
S
RD BL
OR YL
26
48
0
1
CAPACITOR
FAN
MOTOR
NOTE
CA
(AIR CLEANER
MODEL
ONLY)
BL
BK
BR
RD
OR
WH
YL
GN/YL:GREEN/YELLOW
: OPTIONAL PARTS
BLUE
BLACK
BROWN
RED
ORANGE
WHITE
YELLOW
:
:
:
:
:
:
:
3456
(5) LP-K3023HA/HL/HM

- 12 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
(1) The function of main control
1. Time Delay Safety Control
3min The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle.
(Protection of compressor)
3sec The indoor fan is ceased for 3 seconds to prevent relay noise.
(Protection of fan relay and micro chip)
30sec The 4-way valve is ceased for 30 sec. to prevent the refrigerant-gas abnormal noise when the Heating
operation is OFF or switched to the other operation mode.
2. Airflow Direction Control
This function is to swing the louver left and right automatically and to set it at the desired position.
The procedure is as the following.
1st : Press the ON/OFF Button to operate the product.
2nd : Press the Airflow Direction Control Button to swing the louver left and right automatically.
(Remote controller)
3rd : Repress the Airflow Direction Control Button to set the louver as the desired position.
(Remote controller)
3. Cooling Mode Operation
When selecting the Cooling( ) Mode Operation, the unit will operate according to the setting by the
controller and the operation diagram is as following.
Intake Air temp.
Setting Temp. +1°C
(Compressor ON)
Setting Temp. -1°C
(Compressor OFF)
Indoor Fan Speed Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
3 minutes
More than
3 minutes
More than
Compressor ON OFF ON OFF ON
Operation Details
4. Off Timer Function
This function is to set the time of stopping the unit operation.
The procedure is as the following.
1st: Press the timer set button on the Remocon.
2nd: The buzzer sounds and then the display window shows the Off-Time to be set as
- The Off-Time is shifted as the following by each press.
- If you select ' ', the Off-Timer function will be cancelled.
- During Off-Timer Operation, if you repress the timer set button, the rest time will be displayed.
....

- 13 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
5. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
Intake Air Temp.
Setting Temp.
(Compressor ON)
Setting Temp. -1°C
Indoor Fan Speed
Compressor
Electric Heater(Option)
ON
ON
OFF ON OFF
OFFOFF ON OFF
OFF
Hot
Start
minimum
10sec.
minimum
10sec.
minimum
10sec.
minimum
10sec.
OFF
AA
OFFLOW LOW
Setting Temp. +1°C
(Compressor OFF)
Selecting
fan speed
Selecting
fan speed
•A point: The indoor pipe temperature to be less then 35°C & Discharge air Temperature to be less than 29°C.
The indoor fan operates for minimum 10sec. even if falls lower than 34°C.
Low(V)Stop(VI)
39˚C
Discharge Air Temp.
Indoor Pipe Temp.
34˚C
28˚C
26˚C
Selecting Fan Speed(IV)
Low(II)Stop(I)
(Hot-Start Operating)
Heating Start
(Hot-Start Release Point)
Selecting Fan Speed(III)
During heating operation, the operating procedure of the indoor fan is as the following.
Step Indoor fan speed Pipe temp. Air discharge temp.
Off 28 C(Hot start operating)
Low 28 C < 39°C
Selecting speed 28 C ≥39°C
Selecting speed 28 C > 34°C
Low 26 C ≤34°C
Off 26 C

- 14 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
5-1. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
Intake Air Temp.
Setting Temp.
(Compressor ON)
Setting Temp. -1°C
Indoor Fan Speed
Compressor
Electric Heater(Option)
ON
ON
OFF ON OFF
OFFOFF ON OFF
OFF
Hot
Start
minimum
10sec.
minimum
1min
minimum
10sec.
OFF
AA
OFFLOW
LOW
LOW
Setting Temp. +1°C
(Compressor OFF)
Selecting
fan speed
Selecting
fan speed
•A point: The indoor pipe temperature to be less than B°C.
The indoor fan operates for minimum 10sec. even if the indoor pipe temperature falls lower than B°C.
Low(V)Stop(VI)
C˚C
Indoor Pipe Temp. D˚C
22˚C
20˚C
Selecting Fan Speed(IV)
Low(II)Stop(I)
(Hot-Start Operating)
Heating Start
(Hot-Start Release Point)
Selecting Fan Speed(III)
During heating operation, the operating procedure of the indoor fan is as the following.
Step Indoor fan speed Pipe temp.
Off ≤22°C(Hot start operating)
Low ≥22°C
Selecting speed ≥C°C
Low ≤D°C
Off ≤20°C
Heat OFF Heat ON
Indoor Temp. Indoor Temp.
15°C20°C20°C15°C20°C20°C
C°C32°C34°C36°C30°C31°C33°C
D°C28°C30°C32°C26°C28°C30°C
B°C27°C29°C31°C- - -

- 15 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
6. Hot-Start Control
•The indoor fan stops until the evaporator piping temperature will be reached to 28°C.
•During heating operation, if piping temperatures fall below 26°C fan stops.
•The operation diagram is as following.
7. Defrost Control
•Defrost operation is controlled by timer and sensing temperature of outdoor pipe.
•The first defrost starts only when the outdoor pipe temperature falls below -6°C after 45 minutes passed from
starting of heating operation and more than.
•Defrost ends after 10 minutes pass from starting of defrost operation or when the outdoor pipe temperature rises
over 12°C even if before 10 minutes.
•The second defrost starts only when the outdoor pipe temperature falls below -6°C after 45 minutes pass from
ending of the first defrost and more than.
INDOOR PIPE
TEMP.
INDOOR FAN
SPEED
Selecting
fan speed
OFF OFFLOW
1min
Maximum
COMPRESSOR ON
28°C
26°C
More than 45 minutes of
heating operation
Outdoor Pipe Temp.
Indoor Fan
Compressor
4-Way Valve
ON
ON
ON
ON
OFF
ON
OFF
HOT-
START
ON
ON OFF OFFON
12°C
(Defrost OFF)
-6°C
(Defrost ON)
Within
10 minutes
Defrost
Defrost
More than 45 minutes of
heating operation

- 16 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
11. Child Lock function
This function is to operate Air conditioner only by Remocon.
The procedure is as the following
1st: Press the 2 buttons of the temperature control simultaneously, to raise-to lower on the Display Panel of the
product for more 3 seconds.
2nd: The buzzer sounds and then the window of Display Panel shows
CCLL
(CL) mark.
3rd: To release this function, the reverse again the operating procedure could be done.
❈During this function is operating, any buttons of Display Panel don't work. But it is possible to operate with
Remote controller.
9. Protection of the evaporator pipe from frosting
•Compressor and outdoor fan stop when indoor pipe temperature is below -2°C and restart at the pipe temperature
is above 12°C.
10. Air Purifying Operation(CA, HA, ZA Model only)
8. Soft Dry Operation Mode
•During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°C, the compressor
OFF temperature is the setting temperature minus 1°C.
•When the room temperature rises over the compressor ON temperature, the operation mode is switched to the Cool-
ing mode.
•When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
•The operation diagram is shown below.
Intake Air Temp.
Indoor Fan Speed LOW
Selecting
fan speed
Selecting
fan speed
LOW LOW LOW LOW
Compressor OFFON ONON OFF OFF ON
LOW
OFF
Setting Temp. +2°C
(Compressor ON)
Setting Temp. -1°C
(Compresso OFF)
Operation
Cooling
Cooling
operation
Dry operation
3 min. 3 min.
10 min.
maximum
7 min. maximum
10 min.
Mode Selecting
Operating Mode
Fan Speed Outdoor OFF
Initial Starting
of Air purifying
Operation
- Low at the initial
- But could be
switched to Med.
Hi
OFF
- Outdoor not operating
- Fan operating + Air puri-
fying operating
Repress Air
purifying
Button or
ON/OFF
Button
When switched
to Air purifying
operation
Selecting Speed
of Main Operating
Mode
ON or OFF
depend on
main operat-
ing
- Outdoor operating
- Main Operating +
Air purifying operating

- 17 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
12. Alarm mode display / only displayed while operating.
CCOO
: The sensor for sensing room temperature is open or short.
CC11
: The sensor for sensing piping temperature is open or short.
13. Jet Cool
❏During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed
setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time
in a hot summer.
In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.
❏You can select this function during the operation of Cooling/ Soft Dry/ Auto/ Fan.
❏When it is selected, JET COOL lamp is on immediately and fan speed graphic(red) is on 3 times off.
❏Possible to select or cancel using JET COOL key.
❏To cancel the JET COOL Mode, press the JET COOL button again or the Fan Speed button or the Room
Temperature Setting button and the unit will operate in high Fan speed on Cooling mode(set up to 18°C).
❏During the operation when it stops and runs again setting up is high fan speed on cooling mode(set up to
18°C).
14. Energy Saving
➀If setting temperature of starting energy saving operation is under 22°C, first, setting temperature it up to
22°C and perform energy saving operation.
➁After energy saving operation starts, if adaptation time of the human body pass from the point which room
temperature and setting temperature meet together, increase setting temperature 1°C more.
➂If it doesn't satisfy number ➀even in 50 minutes from the start of energy saving operation, increase 1°C.
➃After increasing setting temperature 1°C more by number ➀, ➁, perform number ➁, ➂again, if setting tem-
perature goes up to 25°C, maintain this temperature.
➄If setting temperature goes down to under 25°C, during the operation, do number ➁, ➂, ➃again.
15. AUTO RESTART
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
Setting energy
saving operation
Setting temp.
23˚C
21˚C
22˚C
23˚C
24˚C
25˚C
26˚C
27˚C
Setting temp.
24˚C
Setting temp.
25˚C
maintains setting temp.
25˚C
28min.
50min. 50min. 50min.
35min. 47min.

- 18 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
16. Function of changing set temperature when re-operation after stop.
Operation is set the following condition when re-operation with start/stop button.
1.Operation mode.
Cooling/soft dry mode Cooling mode
Heating mode Heating mode
2. Setting the set temperature when cooling operation.
Room temperature > Set temperature: to be set to the previous set temperature.
Room temperature ≤Set temperature
a) Room temperature ≥26°C: to be set to 24°C
b) 22°C ≤Room temperature ≤25°C: to be set to 21°C
c) 19°C ≤Room temperature ≤21°C: to be set to -1°C less than room temperature.
d) Room temperature ≤18°C: to be set to 18°C
3. Setting the set temperature when heating operation.
Room temperature < Set temperature: to be set to the previous set temperature.
Room temperature ≥Set temperature
a) Room temperature ≤20°C: to be set to 23°C
b) 21°C ≤Room temperature ≤25°C: to be set to 26°C
c) 26°C ≤Room temperature ≤28°C: to be set to +1°C more than room temperature.
d) 29°C ≤Room temperature : to be set to 30°C
17. Function for test operation
1) Outline of Operation
- This is for checking the condition of installation during the installation, and it is operated by cooling, Fan speed
is high, comp. on, and Auto air flow operations without setting temperature.
2) Operation or Cancel
- Do test operation, if you push ON/OFF button and the down room temperature checking button over 3 sec-
onds at the same time.
- During the operation, if you push the stop button or push ON/OFF button and the down room temperature
checking button over 3 seconds at the same time, the test operation will be cancelled and unit come to rest.
- During the operation, if you input remocon key or key on Display panel, it performs its duties.
3) Function
- It operates cooling, fan speed is high, auto air flow operation, comp. on for 18 ± 1 minutes, regardless of room
temperature.
- After 18 ± 1 minutes of operation, it becomes off itself.
- During the operation, signal 8888stands for "LLoo"

1. Selection of the best location
1) Indoor unit
•There should not be any heat source or steam
near the unit.
•There should not be any obstacles to prevent the
air circulation.
•A place where air circulation in the room will be
good.
•A place where drainage can be easily obtained.
•A place where noise prevention is taken into con-
sideration.
•Do not install the unit near the door way.
•Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
2) Outdoor unit
•If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted.
•There should not be any animals or plants which
could be affected by discharged hot air.
•Ensure the space indicated by arrows from the
wall, ceiling, fence, or other obstacles.
- 19 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
Installation of Indoor, Outdoor Unit
50cm
50cm
50cm
100cm
5cm
5cm
40cm
100cm
A
B
Indoor unit
Outdoor unit
3) Piping length and the elevation
Cooling Only Model
5/8" 1/4" 30 20
5/8" 3/8" 30 20
5/8" 3/8" 30 20
20K
28K/30K
40K
PIPE SIZE
MODEL
GAS SIDE LIQUID SIDE
Max.
Length
A (m)
Max.
Elevation
B (m)

- 20 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes LGE Internal Use Only
2. Indoor Unit installation
The mounting floor should be strong and solid
enough to prevent it from vibration.
Drill the piping hole with 70mm diameter hole-
core drill at either the right or the left of indoor
unit. The hole should be sightly slant to the out-
door side.
Insert the plastic tube through the hole.
Cut the extruded outside part of the plastic tube,
if necessary.
3. Outdoor unit Installation
Install the outdoor unit on the concrete or any
solid base securely and horizontally by securing
it with bolts (Ø12mm) and nuts.
If there is any vibration transmitted to the build-
ing, mount the rubber underneath the outdoor
unit.
4. Refrigerant amount
Before shipment, this air conditioner is filled with
the rated amount of refrigerant including additional
amount required for air-purging, subject to 5m pip-
ing length. (The rated amount of refrigerant is indi-
cated on the name plate.) But when the piping
length exceeds 5 meters, additional charge is
required according to the following table.
Example)
In case of 10m long pipe(one-way), the amount of
refrigerant to be replenished is:
(10 - 5) x 30 = 150g
Wall
Core Drill
Tilt
Cut if necessary
More than 15mm
Wall
Plastic tube
(Bushing)
INSIDE OUTSIDE
200mm
70mm 70mm
90mm
MODEL
LP-K Series
REFRIGERANT CHARGE
30g per 1m
This manual suits for next models
23
Table of contents
Other LG Air Conditioner manuals