LG Energy Solution RESU10H Prime User manual

Installation Manual for RESU10H Prime
LG Energy Solution strongly advises users to exercise due care in following LG Energy
Solution’s product installation manual. Warranty claims are invalid if damage is caused
by human error in a manner inconsistent with the installation manual’s instructions.
Version 1.02
Scan QR code to view
[Installation Video Guide]
Scan QR code to view
[Installation Manual PDF File]

ENGLISH
2
The information included in this manual is accurate at the time of publication.
However, this manual is subject to change without prior notice. In addition, the illustrations
LQWKLVPDQXDODUHPHDQWRQO\WRKHOSH[SODLQV\VWHPFRQ¿JXUDWLRQFRQFHSWVDQGLQVWDOODWLRQ
instructions.
Please note the images shown are for illustration purposes only.
Contents
1 Safety
1.1 Symbols
1.2 Safety Instructions
1.2.1 General Safety Precautions
1.2.2 Battery Handling Guide
1.2.3 Response to Emergency Situations
1.3 Warning Label
4XDOL¿HG3HUVRQQHO
2 Product Introduction
2.1 Technical Data
2.1.1 Dimensions and Weight
2.1.2 Performance
2.2 Features
2.3 Maintenance
3DFNDJLQJ6SHFL¿FDWLRQV
3 Installation
3.1 Mechanical Requirements
3.1.1 Package Contents
3.1.2 Basic lifting guide
3.1.3 Unboxing the Package
3.1.4 Installation Location
3.1.5 Clearance
3.1.6 Tools & Safety Gear Required
3.1.7 Appearance and Dimensions
3.1.8 System Clearance
3.1.9 Installing the Battery Pack
3.2 Installation process for Remote Monitoring Device (RMD)
3.2.1 Prepare for installation using RMD
3.2.2 Installation via RMD
3.3 Cable Connections
&DEOH&RQ¿JXUDWLRQ
3.3.2 Guide for cable connection and setting the DIP switch
3.3.3 Spring Terminal Blocks
4 Commissioning
4.1 LED Indicators
4.2 Powering On the Battery Pack
6KXWWLQJ2൵WKH%DWWHU\3DFN
5 Troubleshooting
5.1 Troubleshooting Overview
5.1.1 Post-Installation Checklist
5.1.2 Troubleshooting Guidelines
6 Uninstallation & Return
6.1 Return/Replacement Instructions
6.1.1 Uninstallation
6.1.2 Contact Information
7. Appendix
7.1 Connection in RESU10H Prime parallel battery system
7.1.1 Setting for communication termination resistor (About Section B)
7.1.2 Power cable (When using a combiner box)
7.2 R MD Applications
7.2.1 Battery Status check via RMD
7.2.2 BMS, DC/DC and RMD Update via RMD
7.2.3 Installation via RMD for web user

3
1 Safety
1.1 Symbols
Caution, risk of electric shock
'RQRWSODFHRULQVWDOOQHDUÀDPPDEOHRUH[SORVLYHPDWHULDOV
Install the product out of reach of children
Read the instruction manual, in its entirety, before starting installation
and operation
Heavy weight may cause serious back injuries
Do not dispose of the product with household waste
Recyclable
Disconnect the equipment before carrying out maintenance or repair
Observe precautions for handling electrostatic-sensitive devices
Protective Class 1
Caution, risk of electric shock, energy storage timed discharge.
1.2 Safety Instructions
For safety reasons, installers are responsible for familiarizing themselves with the contents of
this document and all warnings before performing installation and servicing.
1.2.1 General Safety Precautions
Over-voltages or wrong wiring can damage the battery pack and cause combustion which can
be extremely dangerous.
$Q\W\SHRISURGXFWEUHDNGRZQPD\OHDGWRDOHDNDJHRIHOHFWURO\WHVRUÀDPPDEOHJDV
$YRLGLQVWDOOLQJWKHEDWWHU\SDFNZKHUHÀDPPDEOHPDWHULDOVDUHVWRUHG'RQRWLQVWDOOLQSODFHV
where explosive gas or chemicals are present.
During installation of the battery, the utility grid and solar input must be disconnected from the
%DWWHU\3DFNZLULQJ:LULQJPXVWEHFDUULHGRXWE\TXDOL¿HGSHUVRQQHO
%DWWHU\SDFNVKRXOGRQO\EHVHUYLFHGE\TXDOL¿HGSHUVRQQHO
The electronics inside the battery pack are vulnerable to electrostatic discharge.
Be sure to be grounded before handling the battery pack.
Read the label with Warning Symbols and Precautions, which are visible under the Battery
Cover (see Section 1.3 Warning Label).
1.2.2 Battery Handling Guide
'RQRWH[SRVHWKHEDWWHU\WRDQRSHQÀDPH
'RQRWSODFHWKHSURGXFWQHDUWRKLJKO\ÀDPPDEOHPDWHULDOV
Do not expose or place near water sources such as downspouts or sprinklers.
Do not store or install the product in direct sunlight.
Do not install the product in an airtight enclosure or in an area without ventilation.
Do not install the product in living area of dwelling units or in sleeping units other
than within utility closets and storage or utility spaces.
Store in a cool and dry place. (Do not store in greenhouses or storage areas for
KD\VWUDZFKD൵DQLPDOIHHGIHUWLOL]HUYHJHWDEOHVRUIUXLWSURGXFWV
6WRUHWKHSURGXFWRQDÀDWOHYHOVXUIDFH
Store the product out of reach of children and animals.
Store the product in clean environment, free of dust, dirt and debris.
'RQRWGLVFRQQHFWGLVDVVHPEOHRUUHSDLUWKHSURGXFWXQTXDOL¿HGSHUVRQQHO2QO\
TXDOL¿HGSHUVRQDODUHWRKDQGOHLQVWDOODQGVHUYLFHWKH3URGXFW
Do not damage the Product by dropping, deforming, impacting, cutting or
SHQHWUDWLQJZLWKDVKDUSREMHFW'RLQJVRPD\FDXVHD¿UHRUOHDNDJHRI
electrolytes.
Do not touch the product if liquid spills on it. There is a risk of electric shock.
Handle the battery wearing insulated gloves.
'RQRWVWHSRQWKHSURGXFWRUWKHSURGXFWཚVSDFNDJLQJVLQFHWKHSURGXFWPD\EH
damaged.
'RQRWSODFHDQ\IRUHLJQREMHFWVRQWRSRIWKH%DWWHU\3DFNDQGRQWKHFRROLQJ¿Q
Do not put the battery pack upside down on the ground.
Do not connect the power cables at terminal the block in the opposite direction.
Do not charge or discharge a damaged battery.
If the Product is installed in a garage or carport, ensure there is adequate clearance
from vehicles.
7KHEDWWHU\SDFNKDVEHHQFHUWL¿HG,3DQGFDQEHLQVWDOOHGLQGRRUVDVZHOO
as outdoors. However, if installed outdoors, do not allow the battery pack to be
exposed to direct sunlight or water sources, as they may cause:
- Power limitation phenomena in the battery (with a resulting decrease in energy
production by the system).
- Premature wear of the electrical/electromechanical and mechanical components.
- Reduction in performance, performance warranty and possible damage of the battery
Only use the product with a LGES-authorized inverter.
For a list of compatible inverters, visit the LG ESS Battery Website by the URL
below and check the ‘Home Battery’ > ‘Product Info’ menu.
https://www.lgessbattery.com/us (in case of North America)
https://www.lgessbattery.com/au (in case of Australia)
https://www.lgessbattery.com/eu (in case of all EU-countries in general)
https://www.lgessbattery.com/de (in case of Germany)
https://www.lgessbattery.com/it (in case of Italy)
https://www.lgessbattery.com/es (in case of Spain)
Do not connect any AC conductors or photovoltaic conductors directly to the
battery pack. These are only to be connected to the inverter.
1.2.3 Response to Emergency Situations
The Product includes internal fault mechanisms designed to prevent failures and subsequent
risk hazards. However, LG Energy Solution cannot guarantee safety performance of the
Product is ever exposed to abuse, damage or negligence.
If a user happens to be exposed to the internal materials of the battery cell due to
damage on the outer casing, the following actions are recommended.
In case of inhalation: Leave the contaminated area immediately and seek medical
attention.
In case of contact with eyes: Rinse eyes with running water for 15 minutes and
seek medical attention.
In case of contact with skin: Wash the contacted area with soap thoroughly and
seek medical attention.
In case of ingestion: Induce vomiting and seek medical attention.
,ID¿UHEUHDNVRXWDWWKHORFDWLRQZKHUHWKHEDWWHU\SDFNLVLQVWDOOHGSHUIRUPWKHIROORZLQJ
countermeasures.
8WLOL]H¿UHH[WLQJXLVKLQJPHGLD
A respirator is not required during normal operation.
8VHDQ)0RU&2H[WLQJXLVKHUIRUEDWWHU\¿UHV
8VHDQ$%&¿UHH[WLQJXLVKHULIWKH¿UHLVQRWIURPWKHEDWWHU\DQGKDVQRW\HWVSUHDGWRLW
)ROORZSURSHU¿UH¿JKWLQJLQVWUXFWLRQV
1. ,ID¿UHRFFXUVZKHQFKDUJLQJEDWWHULHVSURYLGHGLWLVVDIHWRGRVRGLVFRQQHFW
WKHEDWWHU\SDFNFLUFXLWEUHDNHUWRVKXWR൵WKHSRZHUFKDUJH
2. ,IWKHEDWWHU\SDFNLVQRWRQ¿UH\HWH[WLQJXLVKWKH¿UHEHIRUHWKHEDWWHU\SDFN
FDWFKHV¿UHSUHIHUDEO\ZLWKZDWHU
3. ,IWKHEDWWHU\SDFNLVRQ¿UHGRQRWWU\WRH[WLQJXLVKLWDQGHYDFXDWHSHRSOH
from the premises immediately.
WARNING
There may be a possible explosion when batteries are heated above 150°C. When a
battery pack is burning, it will leak poisonous gases. Do not approach it.
(൵HFWLYHZD\VWRGHDOZLWKDFFLGHQWV
2QODQG3ODFHWKHGDPDJHGEDWWHU\LQWRDVHJUHJDWHGSODFHDQGFDOO\RXUORFDO¿UH
department or service engineer.
In water: Stay out of the water and do not touch anything if any part of the battery, inverter,
or wiring is submerged.
Do not use the submerged battery again. Contact your service engineer for assistance.

ENGLISH
4
1.3 Warning Label
Product/warning label and Battery Control Unit’s traceability label are behind the front cover.
The front cover opens by turning the front cover handle counterclockwise. Battery Modules’
traceability labels are attached to the side of the Battery Modules.
1
2-1
2-2
2-2
Placethespacer
Intheline HERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Placethespacer
InthelineHERE
Handle
Turn counterclockwise
1. Product/Warning Label
2. Traceability label
2-1. Battery Control Unit 2-2. Battery Module
EH153064P8S1DMA
żżżżżżżżżż
SH077064P8S1BMA
żżżżżżżżżżA
SH077064P8S1BMA
żżżżżżżżżżB
4XDOL¿HG3HUVRQQHO
7KLVJXLGHIRUWKHWDVNVDQGSURFHGXUHVGHVFULEHGKHUHLQLVLQWHQGHGIRUXVHE\VNLOOHGVWD൵
RQO\$VNLOOHGVWD൵LVGH¿QHGDVDWUDLQHGDQGTXDOL¿HGHOHFWULFLDQRULQVWDOOHUZKRKDVDOORI
the following skills and experience:
.QRZOHGJHRIWKHIXQFWLRQDOSULQFLSOHVDQGRSHUDWLRQRIRQJULGDQGR൵JULG
(backup) systems
Knowledge of the dangers and risks associated with installing and using electrical
devices and acceptable mitigation methods
Knowledge of the installation of electrical devices
Knowledge of and adherence to this guide and all safety precautions and best
practices
4XDOL¿FDWLRQVSHFL¿HGLQEDWWHU\ZDUUDQW\¿OH
5(68FHUWL¿FDWLRQLQWKHEDWWHU\ZHEVLWH
: Knowledge of local installation standards
: Electrical license for battery installation required by the country or state
Repair the battery by disassembly is possible only at the LG Service Center or by
DSHUVRQZKRLVVSHFLDOO\DXWKRUL]HGVHSDUDWHO\IURPWKHLQVWDOODWLRQTXDOL¿FDWLRQ
2 Product Introduction
2.1 Technical Data
2.1.1 Dimensions and Weight
RESU10H Prime
Part Number EH153064P8S1
Width 504 mm (19.8”)
Height 817 mm (32.2”)
Depth 295 mm (11.6”)
Weight 1) 111 kg (244 lbs)
1) Battery pack weights may vary slightly.
2.1.2 Performance
Electrical Characteristics
Usable Energy 1) 9.6 kWh
Battery Capacity 64.1 Ah
Voltage Range 350 to 450 VDC
Absolute Max. Voltage 595 VDC
Max. Current (charging/discharging) 14.3A @ 350V
Max. Power (charging/discharging) 5 kW
Peak Power 2) (only discharging) 7 kW for 10 sec.
Peak Current (only discharging) 20.9 A for 10 sec.
Communication Interface RS485/ CAN
DC Disconnect Circuit Breaker
Connection Method Spring Type Connector
User Interface LEDs for Normal and Fault Operation
Operating Conditions
Installation Location Indoor/Outdoor
Operating Temperature charge 14°F to 122°F (-10°C to 50°C)
discharge -4°F to 122°F (-20°C to 50°C)
Operating Temperature
(Recommended)
59°F to 86°F (15°C to 30°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C), acceptable for 7
days in total
-4°F to 113°F (-20°C to 45°C), acceptable for the
¿UVWPRQWKV
-4°F to 86°F (-20°C to 30°C), acceptable for months
7~12
Humidity 5% to 95%
Altitude Max. 6,562 ft (2,000 m)
Cooling Strategy Natural Convection
&HUWL¿FDWLRQ
Safety Cell
Battery
Pack
UL1642
CE / RCM / IEC 62619 / UL1973 /
IEC62477-1
Emissions FCC
+D]DUGRXV0DWHULDOV&ODVVL¿FDWLRQ Class 9
Transportation UN38.3
Ingress Rating IP55
ဵ7HVW&RQGLWLRQV7HPSHUDWXUH&)DWWKHEHJLQQLQJRIOLIH
ဵ(QHUJ\LVPHDVXUHGXQGHUVSHFL¿FFRQGLWLRQVIURP/*(QHUJ\6ROXWLRQ&3&9&3
1) Value for battery pack only. Maximal usable energy at the AC output may vary by condition,
VXFKDVLQYHUWHUH൶FLHQF\FRQ¿JXUDWLRQDQGWHPSHUDWXUH
2) Peak current excludes repeated short duration (less than 10 sec. of current pattern).
817 mm
(32.2”)
295 mm
(11.6")
504 mm
(19.8")

5
1. Short Circuit Current/Duration
Short Circuit Current 1.106 kA
Duration 0.97 ms
2. Arc Flash Protection Calculations
,QRUGHUWRSURWHFWSHUVRQQHOIURPWKHSRVVLELOLW\RIJHWWLQJLQMXUHGE\DQDUFÀDVK
KD]DUG$UFÀDVKFDOFXODWLRQRIWKHEDWWHU\V\VWHPLVHVWLPDWHGZLWKWKH,QFLGHQW(QHUJ\
Calculations refer to Annex D of NFPA 70E.
Battery System Voltage 171.4V
Battery System Internal Resistance ȍ
Bolted Fault Current 1.106 kA
Arcing Current 0.553 kA
Clearing Time 792 us
Arc Flash Incident Energy 0.000088 Cal/cm
2
Working Distance 450 mm (18inches)
Battery system installers must wear PPE (Personal Protective Equipment) according to
NFPA 70E Article 130.
WARNING
When installing the battery system, the worker shall wear arc-rated clothing
in every occasions and places to protect him/her from any possible exposure
WRDQHOHFWULFDUFÀDVK
The arc-rated clothing worn by the worker must assure the worker’s
movement and visibility while covering all ignitable clothing.
The worker shall always wear the non-conductive safety helmet every
occasions and places to protect him/her from any danger of head injury
from electric shock or burns due to the contact with energized electrical
conductors or circuit parts resulting from electrical explosion.
The worker shall wear non-conductive protective equipment for the face,
neck, and chin at every occasion and location to protect him/her from danger
RILQMXU\IURPH[SRVXUHWRHOHFWULFDUFVRUÀDVKHVUHVXOWLQJIURPDQHOHFWULFDO
explosion.
The worker shall wear non-conductive protective equipment for the eyes at
every occasion and location to protect him/her from any danger of injury
IURPHOHFWULFDUFVRUÀDVKHVUHVXOWLQJIURPDQHOHFWULFDOH[SORVLRQ
7KHZRUNHUVKDOOZHDUKHDULQJSURWHFWLRQZLWKLQWKHDUFÀDVKERXQGDU\
The worker shall wear heavy-duty leather gloves or arc-rated gloves,
VDWLVI\LQJWKHIROORZLQJUHJXODWLRQOHYHOIRUDUFÀDVKSURWHFWLRQ,QWKHFDVH
of wearing the rubber gloves for the shock protection, he/she shall wear
additional leather protectors above the gloves.
The worker shall wear heavy-duty leather footwear or dielectric footwear or
ERWKWRSURYLGHVRPHDUFÀDVKSURWHFWLRQ
The worker shall inspect arc-rated apparel before every use. Work clothing
RUDUFÀDVKVXLWVWKDWDUHFRQWDPLQDWHGRUGDPDJHGWRWKHH[WHQWLPSDLULQJ
the protective qualities, shall not be used. Protective items that become
FRQWDPLQDWHGZLWKJUHDVHRLOÀDPPDEOHOLTXLGVRUFRPEXVWLEOHPDWHULDOV
shall not be used.
The garment manufacturer’s instructions for care and maintenance of arc-
rated apparel shall be followed.
Arc-rated apparel shall be stored in a manner that prevents physical damage;
damage from moisture, dust, or other deteriorating agents; or contamination
IURPÀDPPDEOHRUFRPEXVWLEOHPDWHULDOV
2.2 Features
Compact energy storage unit for domestic photovoltaic system compatibility
Residential 400V DC battery pack system: Daily cycle and emergency back up
capability.
DC/DC
Circuit
Breaker
(600V)
++
--
Circuit Breaker
Battery Inverter
Battery Power
Interface
Inverter Power
Interface
Protection devices included as follows:
- Inverter Power Interface for protection against overvoltage, overcurrent, external
short-circuit, reverse polarity, inrush current and over temp.
- Battery Power Interface for protection against internal short-circuit, overvoltage,
overcurrent, over temp and undervoltage.
Flexible installation: Indoors or Outdoors
2.3 Maintenance
RESU10H Prime does not require maintenance during normal operation if properly installed
per the installation manual. In the event of fault, contact the regional service center.
3DFNDJLQJ6SHFL¿FDWLRQV
Category Contents
Size (L×W×H) 720 mm
(28.3”)
845 mm
(33.3”)
910 mm
(35.8”) Outer Size
Qty/Box (ea) 1
Packaging
Materials
Box Corrugated Cardboard Disposable
Inner Corrugated Cardboard Disposable
Pallet Wood Disposable
Weight
Product 111 kg (244.7 lbs)
1 pack/box
(Battery Module (x2) + Battery
Control Unit + enclosed items)
Packaging 39 kg (86.0 lbs) Pallet (10.5kg) + Box (28.5kg)
Gross 150 kg (330.7 lbs) Product + Packaging
3 Installation
3.1 Mechanical Requirements
3.1.1 Package Contents
The following items are included in the package:
Battery Module A&B Battery Control Unit Module Connect
Plate
Module Support
BRKT (x2)
Standing Bracket
1 & 2
Spacer (x2) M6 x L10 Flange
Bolt (x18)
M5 × L200 Long
Flange Bolt (x6)
3/4"-1" Adapter (x2) Cap (x2) Manual Drill template
Cable ties (Optional)
Wall Mounting
Bracket Bottom
(Optional)
Wall Mounting
Bracket Top
(Optional)
Wall Mounting
Bracket Top Support
(Optional)
M6 x L10 Flange
Bolt (x3)
(Optional)
M8 x L15 Sems
Bolt (x8)
This manual suits for next models
1
Table of contents
Other LG Camera Accessories manuals

LG
LG LGES-5048 Original operating instructions

LG
LG CHEM RESU10H User manual

LG
LG CHEM RESU10H User manual

LG
LG RESU16H Prime User manual

LG
LG RESU FLEX Operating and maintenance instructions

LG
LG AJ-LAH2 User manual

LG
LG RESU 10H User manual

LG
LG CAM Plus User manual

LG
LG LPT-A100L User manual

LG
LG ICR18650B3 Owner's manual
Popular Camera Accessories manuals by other brands

Trojan
Trojan GC2 48V quick start guide

Calumet
Calumet 7100 Series CK7114 operating instructions

Ropox
Ropox 4Single Series User manual and installation instructions

Cambo
Cambo Wide DS Digital Series Main operating instructions

Samsung
Samsung SHG-120 Specification sheet

Ryobi
Ryobi BPL-1820 Owner's operating manual