HP90 Recessed Fluorescent H9S2GLR254 or 154
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR254UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88.
To reduce glare the average brightness at 65° shall not exceed 3776 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 74.1%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Specifications (continued)
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white
acrylic enamel. Rust preventative undercoating. Reflector – low iridescence specular
aluminum 95% reflectance.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others)
54=T5 54W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp Ballast Type: <10THD
1 Lamp Elec. T5 HO PG ††
(54 Watt)
2 Lamp Elec. T5 HO PG ††
(54 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 1234 1235 1235
5 1226 1231 1237 117
15 1179 1208 1233 342
25 1088 1151 1202 530
35 957 1051 1121 655
45 791 913 998 698
55 601 750 852 661
65 402 576 713 564
75 207 402 474 384
85 49 68 44 85
90 000
Model No. H9S2GLR154UNVPG
LER = FP - 66.5 IW - 61.9 BF - 1.02
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2010216
Catalog Number: H9S2GLR154UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: Advance ICN-2S54
Report is based on 4500 Lumens per lamp.
Efficiency: 89.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.920 22.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1612. 1860. 2034.
55 1510. 1884. 2140.
65 1371. 1964. 2431.
75 1152. 2238. 2639.
85 810. 1124. 727.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 92 88 86 83 80 83 80 78
02 87 80 73 75 69 65 72 67 64
03 79 69 62 65 59 54 63 57 53
04 72 61 53 57 51 45 55 49 45
05 66 54 46 51 44 39 49 43 38
06 61 49 40 46 39 34 45 38 34
07 57 44 36 42 35 30 41 34 30
08 53 40 33 38 31 27 37 31 26
09 49 37 29 35 28 24 34 28 24
10 46 34 27 32 26 22 32 26 21
ZONE LUMENS % LAMP % FIXT
00-030 989 22.0 24.5
00-040 1644 36.5 40.7
00-060 3002 66.7 74.4
00-090 4036 89.7 100.0
90-180 0000 0.0 000.0
00-180 4036 89.7 100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR254UNVPG
LER = FP - 66.5 IW - 112.39 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2006118
Catalog Number: H9S2GLR254UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: B254UNV-E
Report is based on 4400 Lumens per lamp.
Efficiency: 84.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.800 22.800
0.0 45.0 90.0 FLUX
0 2340 2340 2340
5 2320 2339 2354 223
15 2228 2326 2406 658
25 2079 2280 2417 1044
35 1851 2134 2220 1303
45 1548 1790 1827 1348
55 1173 1345 1428 1197
65 771 963 1099 950
75 383 625 665 597
85 75 95 60 125
90 000
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3179. 3676. 3752.
55 2970. 3405. 3615.
65 2649. 3309. 3776.
75 2149. 3507. 3731.
85 1250. 1583. 1000.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 88 84 82 79 77 79 77 74
02 83 76 70 71 67 63 69 65 61
03 76 67 59 63 57 52 60 56 51
04 69 59 51 56 49 44 54 48 44
05 64 52 45 50 43 38 48 42 38
06 59 47 39 45 38 33 43 37 33
07 54 43 35 41 34 29 39 34 29
08 50 39 32 37 31 26 36 30 26
09 47 36 29 34 28 24 33 27 23
10 44 33 26 31 25 21 31 25 21
ZONE LUMENS % LAMP % FIXT
00-030 1926 21.9 25.9
00-040 3229 36.7 43.4
00-060 5774 65.6 77.5
00-090 7446 84.6 100.0
90-180 000000.0 000.0
00-180 7446 84.6 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
H9 Standard HP90
HY For NYC Code – I.B.E.W. Manufactured
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 5/Folio M32-11 Rev. A