1
Important Safety Instructions
Product Overview
• Disconnect EB from mains power before power supply is being prepa-
red. Do not pull connection cable with force.
• Before connecting the EB to mains power, ensure that the socket is
correctly wired.
• The lamphead must be disconnected from power before changing or
tting the lamp.
• EB must be switched off before connecting or disconnecting the lam-
phead with the lamp head cable. To avoid any danger to the user and
EB, we highly recommend unsing our original LIGHTMAN cables and
connectors.
• Working temperature of the EB is guaranteed between - 20°C and 50°C
• Do not operate the EB in high humidity or explosive gas environments
• within 3 minutes after startup, the ballast is locked and all operations
are invalid (default frequency is 75Hz, brightness is 100%)
The 575/1200/1800 electronic ballast from our LIGHTMAN series provides
an automatic switchable ballast for 575W / 1200W / 1800W metal halide
lamps. It features high efciency, power density and automatic problem
analysis.
• Flicker-free operation – up to 10‘000 fps (frames per second)
• uctuation of output light is less than 3%
• compared to inductive EB, light intensity is increased by at least 20%
• constant power output
• constant color temperature
• 50% - 100% power output adjustment
• at least 20% increase of service life (lamp)
• Output frequency: 50 - 1000Hz, Fine-Tuning range: 800Hz - 1200Hz