1 - Safety summary
1 1 Safety
•Always adhere to the pro essional sa ety and accident prevention
regulations applicable to your country during device installation and
operation;
•installation and maintenance operations have to be carried out by
quali ied personnel only, with power supply disconnected and stationary
mechanical parts;
•device must be used only or the purpose appropriate to its design: use or
purposes other than those or which it has been designed could result in
serious personal and/or the environment damage;
•high current, voltage and moving mechanical parts can cause serious or
atal injury;
•warning ! Do not use in explosive or lammable areas;
•ailure to comply with these precautions or with speci ic warnings
elsewhere in this manual violates sa ety standards o design, manu acture,
and intended use o the equipment;
•Lika Electronic assumes no liability or the customer's ailure to comply
with these requirements.
1 2 Electrical safety
•Turn OFF power supply be ore connecting the device;
•connect the unit according to the explanation in the ”4 - Electrical
connections” section on page 11;
•the wires o unused signals must be cut at di erent lengths and insulated
singularly;
•connect Zero setting and Counting direction inputs to 0Vdc, i not used;
- to zero set the encoder, connect the Zero setting input to +Vdc or 100
µs at least, then disconnect +Vdc; normally voltage must be at 0Vdc; zero
setting must be per ormed a ter Counting direction; we suggest
per orming the zero setting when the encoder is in stop;
- Counting direction (see the “3 – Mounting instructions” section):
increasing count = connect to 0Vdc; decreasing count = connect to
+Vdc;
•in compliance with 2014/30/UE norm on electromagnetic
compatibility, ollowing precautions must be taken:
- be ore handling and installing the equipment, discharge
electrical charge rom your body and tools which may come in touch
with the device;
- power supply must be stabilized without noise; install EMC ilters on
device power supply i needed; T or P type LC ilters are o ten adequate;
- always use shielded cables (twisted pair cables whenever possible);
- avoid cables runs longer than necessary;
- avoid running the signal cable near high voltage power cables (e.g. drive
cables);
- install the device as close as possible to the electronic control unit;
- mount the device as ar as possible rom any capacitive or inductive
noise source; shield the device rom noise source i needed;
MAN SMA5 E 1.8.odt 1 - Sa ety summary 6 o 20