LPG Cellu M6 User manual

3
!
In order to respond better to customer requirements or expectations, LPG Systems is continuously researching ways of
improving the design and quality of its products. This will explain the few minor differences between your equipment
and the item described in this guide. If you own a Cellu M6 Keymodule i, some chapters of this user guide do not apply
as specified in this document.
Congratulations on the purchase of your Cellu M6 Keymodule [2]
i
. This model represents the fruits of numerous years of
experience in the design and production of cutaneous tissue
treatment systems. You will experience fully the technical
perfection and reliability of LPG Systems, which is the
leader in this sector. This operator’s manual contains the
operating description, basic maintenance instructions to
be performed periodically and the safety instructions.
You are reminded that your device is designed for the
treatment of connective tissue and that it must only be
used by a professional trained by LPG Systems or an
authorized distributor if you live outside France. If you
have any doubts whatsoever concerning the operation or
maintenance of your equipment, please do not hesitate
to contact LPG the Customer Service Department of your
distributor.
Please read the complete manual carefully
before using your equipment.
© Copyright LPG Systems 2007. LPG, Cellu M6, Keymodule and Endermologie Photo System
are registered trademarks of LPG.
Reproduction, even in part, is strictly prohibited.
GU 350
Edition A dated 03/07
OPERATOR’S MANUAL
Registered trademark
1

!The manufacturer reserves the right to amend the product technical specifications without prior notice. Any reproduc-
tion – even in part – is prohibited. All the illustrations in this operator’s manual are non-binding.
Table of contentsPackage contents
!Unpacking instructions to be retained.
The package contents are identical, except for the Cellu M6 Keymodule i device,
the face heads are not available on this version.
4 5
• One Cellu M6 Keymodule [2]
i
unit
• One main T70 head
• Three Keymodule
• One supply cable
• A set of auxiliary heads
• A set of micro-nozzles/micro-heads
• A set of lift heads
• One operator’s manual
• One maintenance kit
• Marketing environment
1
description of the unit
............................................
p.
6
2
description of the controls
......................................
p.
8
3
precautions for use
..................................................
p.
9
4
maintenance
............................................................
p.
11
5
operating faults
.....................................................
p.
21
6
technical specifications
..........................................
p.
22
7
treatment heads
.....................................................
p.
24
8
warranty
................................................................
p.
39
9
accessories
.............................................................
p.
42

!The unit can only operate if it is connected to the mains by its supply cable and provided the ON switch has been
actuated and the green voltage light is on When the unit is switched on, the pump starts to run automatically for
about ten seconds for priming.
1
description
of the unit
auxiliary
head hose
access door to filters
and maintenance kit
articulating arm
for main head
air inlet for
ventilation
protection strip
gripping area
for raising the unit
main treatment head
main head hose
drawer for storing
the auxiliary heads
keymodule
pivoting wheels
gripping area for
moving the unit
connection
of auxiliary
treatment head
articulating
arm for
auxiliary head
adjustable mobile
arm rods
air outlets from
ventilation circuit
electrical
cable support
on/off switch
main’s filter
and fuse holder
access door
to technical
elements
electrical cable
data plate
BEFORE USE MAKE SURE THAT THE SUPPLY CABLE IS COMPLETELY UNWOUND
Access to the filters
auxiliary head filter
main head filter
maintenance kit
control
panel
Cellu M6® Keymodule [2]i
1
description
of the unit
6 7
Drawer for storing the
series 600 auxiliary heads
Cellu M6 Keymodule [2]iCellu M6 Keymodule i*
!* The auxilary heads are replaced by the 600 series auxilary heads.
monitor screen

• Check that the supply voltage of the unit
indicated on the data plate complies
with the mains voltage.
• The unit must be connected to a grounded
outlet in accordance with current electri-
cal standards.
• Never use the unit on a dusty, uneven
floor, or in a moist atmosphere.
• Check that the inlet to the ventilation
circuit is always unobstructed.
• Fully unwind the supply electrical from
its support to ensure good ventilation
of the unit.
• Switch the unit off if it is not going to
be used for a long period. In this case,
operate the machine for a 1/2 an hour
approximately every 8 weeks.
• Do not allow solid debris or liquid to be
sucked into the unit, as these could
cause damage.
• Never use the auxiliary adapter as a treat-
ment head or allow it to come into direct
contact with the skin.
• Do not use the main head to carry out
treatment on the scalp.
• Only use the treatment heads supplied with
your unit or recommended by LPG.
• Only use LPG Systems treatment garments.
• Never use the unit for purposes
other than those recommended
by LPG Systems.
• LPG Systems will not be liable for any
inappropriate use of the equipment.
• With respect to treated tissue, some
parameters may cause pain or tissue
lesions. The operator must be particularly
attentive to the sensations felt by the person
undergoing treatment where:
- the intensity is greater than 4 in continuous
or sequential mode
(for frequencies less than 4 Hz),
- the system has changed to reverse mode
(rollers rotating in opposite direction).
• The operator must ensure that the
parameters (intensity, sequentiality,
differential...) are always adapted
to the cutaneous tissue being treated.
• You are advised to rest the device for
10 minutes between each 35-minute
treatment session when using it at a room
temperature higher than 25°C (77°F).
!Where the unit has not been used for a long time, it is possible that marks may form on the ground where the wheels
are. This phenomenon is the result of a chemical reaction between the components of some floorings and those of the
wheels of the Cellu M6 Keymodule [2] i.
PrecautionsControl panel
Main head
2
description of
the controls
3
precautions
for use
8 9
control screen
stop/start key
parameters
keys
return to
menu
escape
key
program
selection
keys
roller speed
adjustment keys
frequency
adjustment
keys
roller
selection key
initial roll
selection key
stop/
start keys
control screen

!ALL THE MAINTENANCE OPERATIONS DESCRIBED IN THIS SECTION MUST BE CARRIED OUT WITH THE UNIT
SWITCHED OFF AND THE POWER CABLE DISCONNECTED.
Index
identification rating plate
p.
12
time meters
p.
13
cleaning the unit
p.
14
replacing filter cartridges
p.
15
replacing fuses
p.
16
instructions for disconnecting the treatment heads
p.
16
access to the technical items
p.
17
replacing the filters of the vacuum generator
p.
18
transport/storage
p.
19
maintenance kit
p.
20
maintenance file
p.
20
4
maintenance
11
• Do not treat open wounds, the eyes,
intra-cavity areas, mucous membranes,
the genitals and breasts.
• In the event of pregnancy, do not treat
the lumbar-abdominal region. Consult
with the doctor with regard to this treat-
ment.
• Do not treat a patient with an infectious
disease, a growing tumour, phlebitis etc.
• Consult with the doctor where the
subject has a case history of tumours
or is in remission.
• Do not treat any swollen or inflamed
areas without seeking medical advice and
without training in the LPG technique in
this particular area.
• Make sure that the patient does not have
a peacemaker to prevent electronic inter-
ferences.
Contra-indications:
Because of the risk of interference, it is important that the professional ensures the patient
is not equipped with a personal medical device such as a pacemaker. If this is the case, the pro-
fessional should obtain details about the device in question to ensure that any interference will
not affect the correct use of the equipment.
!This unit contains programs to help the operator obtain the best anticipated results for each case undergoing treat-
ment. Under no circumstances may these programs be construed as a guarantee of successful treatment, which varies,
depending on the morphology, physiology and eating behaviour of each patient.
Contra-indications
• Do not treat a patient suffering from
inexplicable and persistent pain without
seeking medical advice and without
training in the LPG technique in this
particular area.
• Do not treat a patient following invasive
medical treatment, without seeking the
medical advice of the doctor or surgeon
who performed this operation and without
training in the LPG technique in this par-
ticular area.
For a more detailed list of the indications and
contraindications of Endermologie, please
refer to the training manuals.
As this list is not exhaustive, always seek out
medical advice in the event of doubt.
3
precautions
for use
10

4
maintenance
!The identification rating plate is located on the bottom, behind the unit.
Identification
rating plate
Your unit is identified by a serial number
shown on the rating plate.
The rating plate also shows the permitted sup-
ply voltage for the unit.
If you need to contact LPG Systems
because of a technical problem,
please indicate the serial number of your
Cellu M6 Keymodule [2]i.
This serial number provides information
on the year and month of manufacture
of your unit.
The letter gives the year of manufacture:
V= 2005, W= 2006, X= 2007, Y= 2008, etc.
The two figures indicate the month of produc-
tion: 01= January, 02= February,
03= March, etc.
The corresponding icon indicates that the unit
was sold after August 13, 2006.
In conformity with the 2002/96/CE directive,
it cannot be thrown away with standard house-
hold waste but must be disposed of by means
of recycling.
By doing so, you help the environment by
contributing to the conservation of natural
resources and the protection of human health.
Time meters
serial number
supply voltage
and frequency
year and month
of manufacture
4
maintenance
12
Your unit comprises several TIME METERS
that total the operating hours of the various
units for periodic maintenance purposes.
These meters can be seen at control panel
level, from the CONFIGURATION screen
.
C1: The Main Head Filter Counter totals the
number of operating hours for the main
head filter.
C2: The Auxiliary Head Filter Counter totals
the number of operating hours for the
auxiliary head filter.
C3: The Pump Filter Counter totals the num-
ber of operating hours for the pump.
C4: The Main Head User Counter totals the
number of operating hours for the main
head.
C5: The Keymodule User Counter totals the
number of operating hours for the Key-
module connected to the main head.
13
from the control panel
This pictogram means “Warning, please con-
sult the user guide.”
This pictogram means “Your device comprises
a part that is in contact with the patient that is
isolated electrically from all other parts of the
device.”

4
maintenance
Cleaning
the unit
4
maintenance
14 15
!Do not use aggressive products, such as acetone, trichloroethylene or alcohol, or abrasive sponges.
Replacing
filter cartridges
14 15
We recommend that you clean your unit
as often as possible, not only for reasons
of hygiene and aesthetics but also because
cleaning the unit will help keep it in a good
state of repair and extend its useful life.
Using a vacuum cleaner with a fine nozzle,
clean the following sections:
• The inside of the access drawer to
the auxiliary heads, (having already
removed all the auxiliary heads).
• The inside of the access door to the
filters.
Using a moist sponge, clean the following
sections:
• All the external hoods.
• Hoses.
• The power cable.
Using a cloth soaked with a little domestic
cleaning product not containing alcohol,
clean the following sections:
• Control screen and control panel.
• The inside of the access drawer to
the auxiliary heads.
• The inside of the access door to the
filters.
Your unit has 2 filters. One is for filtering
the circuit of the main head while the other
filters the circuit of the auxiliary heads.
The filter cartridge guarantees the efficiency
of your unit and extends its useful life.
Remember to change the cartridge every
forty hours.
A warning message on the screen indicates
that a filter needs changing. Open the filter
access hood. Unscrew the filter cartridge
and replace the cartridge with a new one.
Remember to purchase new filter cartridges
from the LPG Systems Customer Service
Department so you always have a spare.
Never use your device without filter.

!If fuses with the incorrect rating are used, this could result in damage to the entire electrical system.
Replacing fuses
Your unit is protected against short-circuits
by 2 ceramic 6.3 mm x 32 mm time-delay
fuses.
Fuse replacement:
1. Disconnect the supply cable from
the mains.
2. Loosen one of the 2 fuse holders.
3. Remove the fuse.
4. Repeat the same operation for the
second fuse holder.
Remember to purchase new fuses from
LPG Systems Customer Services, so that
you always have a spare on hand.
Because of its rapid-fit twist connection,
the main treatment head can easily be
disconnected from its hose by loosening
the aluminium connection bush.
To connect the head, take hold of the hose
and proceed with its electrical connection
and then screw tight by tightening
the aluminium bush.
Disconnecting the treatment heads and
hoses is quick and easy.
1. Loosen the two screws and remove the
rear screen located on the mobile arm,
using the small, hex key.
2. Loosen and disconnect the electric
connection.
3. Remove the plastic connection from
its housing.
4. Disconnect the plastic connection.
Disconnect the supply cable.
Open the rear door to gain access to the tech-
nical elements using a screwdriver.
Only loosen the 4 fixing screws a quarter turn.
Instructions for
disconnecting the treatment heads (cont’d)
Instructions for
disconnecting the treatment heads
Access to the
technical items
!Connection system identical for the two circuits.
fuse holder
CERAMIC 6.3 X 32
TIME-DELAY FUSE
electrical
connector
1
2.5 MM
HEX KEY
2
3
4
screwdriver
electrical supply
central control
electronic
control board
vacuum generator
aluminium
bush
4
maintenance
4
maintenance
16 17

!It is important to replace the filter cartridges one after the other, so that the correct cartridge is replaced in its housing.
The Cellu M6 must be switched off before proceeding with a filter cartridge change. The unit must also be cold, so as to
avoid any risk of burning.
Replacing
the filters of the vacuum generator
The vacuum generator has two filter car-
tridges:
• one paper cartridge at the inlet, on the
left side,
• one metal cartridge on the discharge
side, on the right side.
These two cartridges must be replaced after
every 1.000 hours of operation.
No special tool is required for this operation.
1. Open the rear door to gain access to the
technical elements.
2. Loosen the two knurled nuts of the va-
cuum generator hood.
3. Unscrew the cover.
4. Unscrew the central knurled nut.
5. Remove the cartridge from the spring.
6. Replace with a new cartridge.
7. Repeat the same operation for the
second cartridge.
8. Once the new filters are in place, validate
the operation by selecting the icon repre-
senting the filters you have just changed,
by pressing the appropriate key and hold
the VALID.
To confirm replacement, the icon depicting
the filters disappears.
Where the unit is only being moved a short
distance or when stored for a short while
in the folded position, it is essential to insert
the two shims provided for this purpose.
If you require any information on the packag-
ing, shims and procedure to be adopted,
please contact LPG Systems Customer
Services.
1. Fix the treatment heads to their relevant
support using large rubber bands.
2. Loosen the 4 screws using the large
hey key.
3. Pull the top section of the unit upwards.
4. Bend while holding the unit.
5. Insert the various shims in order
to protect the hoods.
Transport/Storage
!LPG Systems will not be liable for damage caused by transport or storage in the folded position, if the shims provided
for this purpose, are not in place.
HEX KEY, 5
acknowledge replacement by
pressing the key for a long time
2
3
4
5
8
hinged system
timber shims
foam shims
4
maintenance
4
maintenance
18 19

Maintenance kit
The tools supplied with the equipment
in the tool box are sufficient to carry out the
maintenance operations defined in this
guide.
Contents of the maintenance kit:
• 4 hole covers,
• 2 spare fuses,
• 2 hexagonal spanners
(model: no. 2.5 and no. 5),
• 1 Torx T30 key,
• 1 Torx T10 key,
• 1 screwdriver.
If your unit is not working properly, pro-
ceed with the following checks
before calling Customer Services:
• Is the unit properly connected to a
mains plug?
• Is the mains plug live?
• Is the ON switch lit up?
• Are the fuses of the unit in good
order?
• Are the filter cartridges clean and
properly in place?
• Are the hoses free?
• Are the hoses properly connected
to the mobile arms of the balancer?
• Are the sealing valves of the main
head in their proper place, clean and
moving?
• Is the Keymodule of the main head
correctly fitted?
• When switching on, the main head
screen is blocked in the MAINTE-
NANCE MENU; there is a problem of
compatibility between the electronic
boards of the T70 and the Cellu M6
Keymodule [2]i. Please contact Cus-
tomer Services of your distributor.
Once these checks have been carried out
and if the malfunction persists, please
contact Customer Services of LPG Sys-
tems or the nearest authorized dealer,
indicating the model of your unit, its serial
number and operating time in hours (see
access to the time meters).
A little problem!
What should I do
Maintenance file
4
maintenance
5
operation
faults
20 21
Replacement of the filter cartridge for the main head circuit .................................................40 hours
Replacement of the filter cartridge for the auxiliary head circuit ...........................................40 hours
Overhaul of the main head ............................................................................approx. every 1.000 hours
Replacement of the vacuum generator filters .....................................................................1.000 hours
Replacing the TML10: Once the TML10 flaps no longer permit proper skin treatment, they should
be replaced. Use the TML10 airtight kit. The airtight kit should be replaced at most every 100 hours’
of operation.
Replacing the TML19 and TML30: Once the TML19 and TML30 flaps no longer permit proper skin
treatment, they should be replaced. Use the TML19 and TM30 airtight kits. These kits should be
replaced at most every 250 hours’ of operation.
date
number of hours
operations carried out

General characteristics
127V - 60 Hz
Supply voltage ..............................................................................127V AC
Frequency ........................................................................................60 Hz
Intensity consumed .............................................................................10A
Power consumed ...................................................................1.200 Watts
Ceramic fuses ................................................................................T12.5A
100V - 60 Hz
Supply voltage ..............................................................................100V AC
Frequency ........................................................................................60 Hz
Intensity consumed .......................................................................... 12.5A
Power consumede ................................................................. 1.250 Watts
Ceramic fuses ...................................................................................T20A
100V - 50 Hz
Supply voltage ..............................................................................100V AC
Frequency .........................................................................................50Hz
Intensity consumed .......................................................................... 12.5A
Power consumed ...................................................................1.000 Watts
Ceramic fuses ...................................................................................T20A
Electrical properties
Dimensions: Length x width x height ............................ 60 x 46 x 210 cm
Net weight .........................................................................................90 kg
Maximum set depression ............................................69 kPa (690 mbar)
Fuses ........................................................................................ Time-delay
.........................................................................................Size 6.3 x 32 mm
Cooling ....... By way of mechanical ventilation incorporated in the pump
Protection index ................................................................................ IP 20
Electrical protection class .......................................................................1
Operating temperature ..........................+10°C to +30°C (+50°F to +86°F)
Storage temperature ............................. -20°C to +70°C (-4°F to +158°F)
Unit fitted with patented treatment heads.
The Cellu M6 Keymodule [2] i is marked as a medical device by virtue of
Annex V of regulation 93/42/EEC (standards 60601-1-1 and 60601-1-2).
!Please consult Customer Services regarding other voltages.
Electrical properties
230V - 50 Hz
Supply voltage .............................................................................230V AC
Frequency ........................................................................................50 Hz
Intensity consumed ..............................................................................4A
Power consumed .....................................................................920 Watts
Ceramic fuses ....................................................................................T8A
220V - 60 Hz
Supply voltage ..............................................................................220V AC
Frequency ........................................................................................60 Hz
Intensity consumed ............................................................................4.8A
Power consumed ...................................................................1.100 Watts
Ceramic fuses .....................................................................................T8A
6
technical
specifications
6
technical
specifications
22 23
0088

Contents
7.A
description of main head
T70 .......................................
p.
26
7.B
description of keymodule
............................................
p.
27
7.C
functions incorporated in the main head
.......................
p.
30
7.D
description of micro-heads/nozzles
.............................
p.
31
7.E
description of lift heads
............................................
p.
31
7.F
functions incorporated in the auxiliary adapter
............
p.
32
7.G
description of auxiliary heads
.....................................
p.
32
7.H
maintenance
.............................................................
p.
33
!The manufacturer reserves the right to amend the product technical specifications without prior notice. Any reproduc-
tion, even in part, is prohibited. All the illustrations of this treatment head supplement are non-binding.
TREATMENT HEAD
Registered trademark
7
treatment
heads
7
treatment
heads
24 25

The Keymodule is the bottom interchange-
able section of the T70 main head. It com-
prises the motorised rollers
and sealing valves.
You have three Keymodule, the character-
istics of which differ from the motorized
rollers in several points:
• Diameter and texture of the rollers.
• Rigidity of return springs on motorised
rollers.
• Roller lenght.
Keymodule i1:
It is characterised by the following points:
• Roller diameter: 26 mm.
• Hard springs.
Keymodule i2:
It is characterised by the following points:
• Roller diameter: 28 mm.
• Soft springs.
Movement and direction of rotation are visu-
ally displayed by LEDs for these Keymodule.
!
Before running your unit for the first time, ensure that a Keymodule is properly connected to the T70.
Keymodule®
Main head T70
monitor screen
rapid twist
connection
main handle
control panel with
adjustment keys
trigger
keymodule
safety grid to prevent
the ingress of foreign
debris
treatment chamber
motorized rollers
electrical contacts
sealing
valve
latch
keymodule
disconnected
keymodule
connected
7. A
description
of main
head
t
70
7. B
description
of keymodule
26 27

7. B
description
of keymodule
InstallationKeymodule®
Every Keymodule is designed to be
compatible with the main head T70.
Attach the Keymodule to the main head
as shown in the photos opposite.
To remove the Keymodule release the lat-
ches.
Keymodule i 50:
is adaptable to the main head of the
Cellu M6 Keymodule [2]i T70. It consists
of two motorised rollers and airtight val-
ves.
It is characterized by the following points:
•
Roller diameter: 26 mm.
•
Roller length: 50 mm.
•
Soft springs.
•
The depth of treatment can be selec-
ted by setting the rollers a distance of
between 28 and 10 mm apart.
electrical
contacts
sealing valve
latch
keymodule
disconnected
keymodule
connected
7. B
description
of keymodule
28 29
Setting the cursor
of keymodule i1, i2 and i50
The Keymodule i1, i2 and i 50 have a cur-
sor, which can be adjusted to 5 positions,
thereby making it possible to adjust the
spacing between the motorized rollers.
When the cursor is in the bottom position
(figure 1) the distance between centres
of the rollers is maximum and fixed, there
is no roller mobility.
When the cursor is in the top position
(figure 2) the distance between centres of
the rollers is variable, from a maximum
position to a minimum position, which
ensures maximum mobility of the rollers.
When the cursor is in one of the 3 inter-
mediate positions (figure 3) the distance
between centres of the rollers,
as well as their mobility, are variable.
123
keymodule
i1, i2
keymodule
i50

7. E
description of
nozzles /
micro head &
lift heads
7. C
functions
incorporated
in the t70
Micro-nozzles and micro-heads serie 600
31
!These functions are only possible provided the main treatment head has been selected.
Functions incorporated
in the main head
Apart from roller speed settings, frequency
or treatment mode (Roll’in or Roll’up), the
main head also incorporates the Start/
Stop and reverse functions and the roller
direction indicator.
Start/Stop:
Once the pump has been switched on via
the START button on the control screen,
starting and stopping the treatment can be
controlled from the main head:
To start treatment, squeeze the trigger
briefly.
To stop treatment, squeeze the trigger for
a longer period. This function can also be
enabled via the START/STOP button on the
head.
Direction of movement indicator (when
the rollers are moving in the same direc-
tion):
Each squeeze of the trigger reverses the
direction the head moves in.
Throughout the treatment, the direction of
movement of the main head is shown by
flashing lights.
Reverse mode and LEDs:
In reverse mode (the rollers are turning in
opposite directions) the way the LEDs flash
becomes more specific:
• in roll’out mode (the 2 rollers roll in
the fold), the 2 LEDs are lit and flash,
• in roll’in mode (the 2 rollers roll out
the fold), the 2 LEDs stay lit.
trigger support
stop key
forward
movement (roll’up)
backward
movement (roll’up)
mode roll’inmode roll’out
30
T7 CONVEX
T7 FLAT
T7 CONCAVE
SUPPORT (COMMON TO ALL THE MICRO-NOZZLES
AND ALL MICRO-HEADS)
MICRO-NOZZLE N°1 AND 2
TML 10 WITH REMOVABLE FLAPS TML 19 WITH REMOVABLE FLAPS TML 30 WITH REMOVABLE FLAPS
Adjusting the force with which the flaps
return:
To guarantee that the flaps return effectively
and therefore to optimize treatment, it is
important to adjust the knob in line with the
intensity of the treatment and the program
selected.
• Turn the knob from A to G to increase the
flap’s return force.
• Turn the knob from G to A to reduce the
flap’s return force.
Lift heads
. D
!This chapter does not apply to Cellu M6 Keymodule i.

7. G
functions incorpor.
in the aux. adapter
/
description of
aux. heads
7. H
maintenance
Cleaning the auxiliary heads
!All the maintenance operations described in this section must be carried out with the unit switched off and the supply
cable disconnected. This chapter does not apply to Cellu M6 Keymodule i.
33
!These functions are only possible provided the auxiliary treatment head has been selected.
Functions
incorporated in the auxiliary adapter
32
control
start/stop
to reduce treatment
intensity
to increase treatment
intensity
Because the control is incorporated in the
auxiliary head connection, you can start or
stop your treatment by operating the START/
STOP switch and adjust the treatment inten-
sity using the +/- keys without having to go to
the control panel of your unit.
Auxiliary
heads serie 600 - active
TYPE: 630A
TYPE: 644A
TYPE: 615A
auxiliary adapter with
incorporated controls
controls
twist connection
↔
↔
.F
When used for specific purposes such as the
after-effects of burns or lymphoedema,
the treatment heads must be thoroughly
disinfected after use:
1. After following the cleaning procedure
described above, soak the head (auxiliary
head, micro-head and micro-nozzle) and
the rollers in a disinfectant solution for
15 minutes.
2. Rinse carefully.
3. Leave to dry.
Warning: Use a non-alkaline disinfectant that complies with
AFNOR standards and has the following microbiological
properties: Bactericide (NF EN 1040, NF T 72-171, NF T 72-
190, T 72-300/301), Fungicide (NF EN 1275, NF T 72-200).
For reasons of hygiene, the treatment
heads should be cleaned before and after
each use with the heads disconnected
from the machine. Use antiseptic wipes
and a bactericidal and fungicidal solution.
Lift head:
1. Before use, clean the flaps and the side
plates.
2. After use, remove the flaps from the head
for more thorough cleaning. Grasp the
flaps between the thumb and index finger
and pull them upwards.
3. Next clean the head’s transparent side
plates with antiseptic wipes and a bacteri-
cidal and fungicidal solution.
Cleaning the lift heads

7. H
maintenance
7. H
maintenance
3534
!Warning: Do not use aggressive products such as acetone, trichloroethylene or surgical spirit or abrasive sponges,
ultrasound or UV lamps. Does not apply to the Cellu M6 Keymodule [2] i.
Cleaning the lift heads (cont’d)
4. Clean the flaps in the same way.
5. Once cleaning is complete, refit the flaps
by pushing them back into their housing,
holding them with the antiseptic wipe.
Removing the TML10 flaps:
The TML10 flaps can be removed and refitted
using the special extractor tool.
1. To remove the flaps, hold the extractor
tool’s sides in, then release them and pull
out both the tool and the flaps.
2. To remove the flaps from the tool, press in
on the sides of the tool.
3. Once cleaning is complete, replace the
flaps as shown below.
Replacing the flaps/airtight kit
Once the flaps no longer permit proper skin
treatment, they should be replaced. Use the
flaps provided with the machine or order
an airtight kit from the Customer Service of
your distributor.
1. TML10 airtight kit.
2. TML19 and TML30 airtight kit.
3. Using the hex key provided in the kit,
remove the side plates by unscrewing
the two screws and replace them with
the new ones.
4. Remove the sealing ring from the treat-
ment head connector and replace
it with the new one.
33
44
2
1

7. H
maintenance
Cleaning
the main head
Cleaning
the main head
7. H
maintenance
3736
Cleaning the Keymodule:
1. Turn the Keymodul and clean the rollers
on either side. Manually turn the rollers
so as to gain access to the entire surface
area.
2. Turn the Keymodule again and refit
the sealing valves as shown on the photos.
3. Do not forget to clean the sealing joint
between the Keymodule and head body.
4. Check that the electrical contacts are
clean and dry and proceed in the reverse
sequence to refit the Keymodule onto the
main head.
Now check that the head is operating
correctly. To do this, operate the head in the
palm of your hands to ensure the correct
sealing of the treatment chamber and
visually inspect the movement of the valves
and that of the rollers.
WARNING: if the Keymodule is not fitted to
the main head, if it is incorrectly positioned
or even faulty, the main head screen will
display the icon alongside:
Check the assembly of the Keymodule.
electrical contacts
sealing joint between
the head body and the
keymodule
For hygiene reasons, the treatment heads
must be cleaned after each use, using
antiseptic wipes with a bactericidal and
fungicidal solution.
Special attention must be paid to those
parts coming into contact with the patient.
Cleaning the tightness valves:
1. Release the Keymodule as shown
on the photos.
2. Make sure that the cursor is in the top
position.
3. Bring the roller to the center.
4. Remove the corresponding sealing valve by
handling it as shown on the photo.
Repeat this operation for the other valve.
5. Then clean the valves and their location.
Replace the valves after:
100 hours’ operation.
!Do not use aggressive products, such as acetone, trichloroethylene or alcohol at 90°, or abrasive sponges.
!Do not use aggressive products, such as acetone, trichloroethylene or alcohol at 90°, or abrasive sponges.

8
warranty
General
warranty conditions
39
Cleaning the auxiliary heads
micro-heads and micro-nozzles
38
7. H
maintenance
You have recently acquired an appliance dis-
tributed by LPG Systems or an LPG Systems
approved distributor. It is the purchaser/us-
er’s responsibility to find out from the local
authorities the conditions and professional
qualifications that should be met before us-
ing the appliance.
The purchase of this equipment implies the
legal acceptance by the purchaser/ profes-
sional user of these general warranty condi-
tions. If the appliance was sold to you by an
approved LPG Systems distributor,
the purchaser/user should refer to the sup-
plier’s warranty conditions. These may in
no way increase the undertakings made in
these present warranty conditions. The war-
ranty can only be implemented and is only
valid if the warranty slip has been duly filled
out and returned to LPG Systems within two
weeks of delivery, irrespective of the coun-
try. Warranty slips that are only partially
completed will be rejected.
The appliance is guaranteed against
manufacturing flaws and defects in the raw
materials. The warranty extends for the
shorter of the following two periods: one (1)
year OR two thousand (2.000) hours of use
from the invoice date. During this period,
LPG Systems undertakes to exchange or
repair free of charge, as quickly as possible,
any part that LPG Systems acknowledges
as defective, however LPG Systems does
not undertake to replace the entire appli-
ance. Traveling and living expenses for our
technicians and transportation costs of the
appliance or parts to and from the after-
sales service workshop are not covered by
this warranty. Replacements and repairs
performed within this warranty, with or with-
out immobilization of the equipment, shall
not have the effect of extending the warranty
period. Replaced parts become the property
of LPG Systems
or the approved distributor.
No compensation
shall be paid for loss of
use. The purchaser/user is required to allow
LPG Systems the necessary time and means
to carry out all repairs and deliveries of
replacement spare parts, Failure to comply
will absolve us from our obligations under
the warranty.
The only courts of competent jurisdiction
are those within the legal district of LPG
Systems’ head office regardless of any juris-
diction clauses in any other document.
Warranty exclusions:
• Damage occurring during transportation.
Transportation of this equipment and/or
spare parts is at the recipient’s own risk.
Before taking delivery, it is the recipi-
ent’s responsibility to verify the state of
the goods and to make a claim against the
transport company in the manner usual in
the delivery country.
• Non-observance of the installation and
operating instructions, failure to carry
out maintenance and/or negligence in
maintaining the appliance and/or its filter
cartridges, connection to a faulty electricity
supply or a non-earthed electricity supply
or a power supply whose voltage is differ-
ent to the one indicated on the appliance.
For hygiene reasons, the treatment heads
must be cleaned after each use, using
wipes containing an antiseptic, bactericidal
and fungicidal* solution.
Cleaning the auxiliary heads:
1. Disconnect the auxiliary head of the adap-
ter for cleaning purposes.
2. Remove the two head rollers to proceed
with quick and efficient cleaning as
shown on the photograph. For mi-
cro-heads, use the micro-head tool
supplied.
3. Clean the rollers and the treatment
chamber.
4. Refit the rollers and check that they
rotate freely.
5. For cleaning the micro-nozzles, use cot-
ton swabs containing the same solution.
The Keymodule is a high-technology
unit comprising numerous mobile micro-me-
chanical parts. The unit must be returned to
our Technical Support Center if certain wear
items require replacing.
The head may start to lose some of its cha-
racteristics at around 1.000 hours
of operation.
micro-head tool
* Do not use aggressive products, such as acetone, trichloroethylene or alcohol at 90°, or abrasive sponges.
Overhaul
of the Keymodule®
!

8
warranty
To be filled
in by the manufacturer
To be completed
and return to LPG Systems
Name: ..........................................................................................................................
Adress: ........................................................................................................................
Country:.......................................................................................................................
Tel.: .............................................................................................................................
Type of establishment: ...............................................................................................
Profession: ..................................................................................................................
Type of unit: Cellu M6 Keymodule [2]i
Serial number: ………….............................………….
Date: ………………………………….......
LPG SYSTEMS S.A.
Technoparc de la Plaine
30, rue du docteur Abel - BP n° 35
26902 VALENCE Cedex - France
RCS Romans B 335 183 836
Tel.: +33 (0)4 75 78 69 00 - Fax: +33 (0)4 75 42 80 85
Type of unit: Cellu M6 Keymodule [2]i
To validate the warranty, detach this slip and return to the address below within 15 days following use of the unit:
LPG SYSTEMS S.A. - Technoparc de la Plaine
30, rue du docteur Abel - BP n° 35 - 26902 VALENCE Cedex 9 - France
✂
!
8
warranty
41
General
warranty conditions (cont’d)
Non-compliance with the general guarantee
conditions during the term of the warranty
and following expiry of the latter, may lead
to LPG Systems being exonerated of any
liability in the event of damage attributed to
the products supplied.
LPG Systems will not be held liable with
respect to equipment/material losses or
physical accidents (i), following installation
that does not comply with the statutory or
regulatory provisions of the country where
the unit is to be used or (ii) which could
jeopardize a Cellu M6 Keymodule [2]i unit,
which was the subject of intervention work
not scheduled in the LPG Systems operator’s
manual and/or carried out by the operator or
a third party not authorized by LPG Systems.
LPG Systems will be absolved of its liability
in the event of use exceeding the level of
professional competence/qualification of the
operator or resulting from the incorrect use
of the unit.
• If an appliance is sold before the end of the
warranty period, the warranty is trans-
ferred to the purchaser for the remaining
warranty period, on the condition:
i) that the original invoice is provided,
ii) that the initial vendor is informed of
the sale.
• Modification, mounting of accessories or
dismantling of the equipment.
• Any operation and/or intervention not
specified in the LPG Systems Operating
Instructions and performed on the equip-
ment by the purchaser/user and/or any
party not approved by LPG Systems.
• Use of consumables, spare parts, inappro-
priate components or parts not supplied by
LPG Systems.
• Blockage of the appliance through aspira-
tion of a foreign body.
• Normal wear and tear of any of the equip-
ment’s parts resulting from normal usage.
• Falls, impacts, lightning, fire, force ma-
jeure, water damage and natural disasters.
Limitation and
exoneration of liability
40
Other manuals for Cellu M6
1
Table of contents
Other LPG Medical Equipment manuals

LPG
LPG HUBER 360 EVOLUTION User manual

LPG
LPG Cellu M6 Endermolab i User manual

LPG
LPG Cellu M6 Alliance User manual

LPG
LPG Mobilift M6 Connect User manual

LPG
LPG HUBER 360 EVOLUTION User manual

LPG
LPG CELLU M6 Alliance Lab Medical User manual

LPG
LPG HUBER 360 EVOLUTION User manual

LPG
LPG WELLBOX S User manual

LPG
LPG CELLU M6 Alliance Medical User manual

LPG
LPG Cellu M6 Alliance Technical manual