ABuilding Safety. Building Security.
Multi Module
MEA244-1
Description
• ADM loop technology with
System Sensor/200 protocol
• 4 independent line-monitored inputs
• 4 independent outputs with patented
monitoring of line resistance and
load resistance
• Optimized for use in extinguishing
systems
• Supply supervised for undervoltage
The Multi Module MEA244-1 has been designed espe-
cially for use in extinguishing systems. It has 4 indepen-
dent inputs for connection of contact detectors, and 4
independent, powerful outputs for actuation of external
control devices.
The inputs are monitored to detect wire breakages and
short circuits of the connection leads. On the outputs
the internal resistances of the control devices and the
line resistances are monitored separately. An automatic
calibration procedure, which gets started by pressing
a key during commissioning, determines the reference
values of both resistances. The patented method of
multiple monitoring makes the reliable detection of line
or load faults as well as contact corrosion possible.
The multi module is used as loop element with inte-
grated dual-isolator, in an ADM loop with System Sen-
sor/200 protocol. The module occupies 8 consecutive
addresses on the ADM loop. During commissioning, the
base address, which is assigned to input 1, gets ente-
red using a key, all further addresses are automatically
assigned by the module.
The MEA244-1 and the connected control devices are
supplied through an external 24V power supply. The
supply voltage gets supervised for undervoltages. If the
voltage drops below the threshold of the undervoltage
detection, then this event is automatically signalled to
the control panel, via the loop, as fault of all four out-
puts. Each input and each output has a status LED.
The multi module is available in two versions:
• The MEA244-1/TR has been designed for mounting
on a DIN rail,
• the MEA244-1/E can be mounted in a control panel
using the supplied mounting spacers.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
MEA244-1_DBL_LST_EN_0823.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Supply voltage 20 to 30VDC
Threshold of undervoltage detection 21.7V (can be increased to 25.3V by using a jumper)
Current consumption at 24V 35mA (quiescent)/max. 160mA (without load)
Current consumption on the loop 500µA
Number of inputs / outputs 4 / 4
Load current per output max. 1.5A
Ambient temperature MEA244-1 -5°C to +60°C
Ambient temperature external control equipment +5°C to +50°C (to ensure the functioning of the fault detection)
Patent number AT 501 215 B1
Approval VdS G205120
Multi module for mounting on rail
Dimensions L × W × H 196 × 97 × 56 (mm)
Weight 310g
Order number 249092
Order name Multi Module/Mounting Rail MEA244-1/TR
Multi module for mounting in control panel
Dimensions L × W × H 194 × 93 × 20 (mm)
Weight 150g
Order number 249095
Order name Multi Module/Panel Mounting MEA244-1/E

This manual suits for next models

1

Other LST Security System manuals

LST Vds 245302 User manual

LST

LST Vds 245302 User manual

LST Serial Interface Module SIM06-1 User manual

LST

LST Serial Interface Module SIM06-1 User manual

LST 55100-908 User manual

LST

LST 55100-908 User manual

LST SZ58-3 User manual

LST

LST SZ58-3 User manual

LST PA58-3 User manual

LST

LST PA58-3 User manual

Popular Security System manuals by other brands

Fluidwell F190-A manual

Fluidwell

Fluidwell F190-A manual

Risco Agility 3 user manual

Risco

Risco Agility 3 user manual

Stark ST-6107W operating manual

Stark

Stark ST-6107W operating manual

GE AL-1291 Point ID installation manual

GE

GE AL-1291 Point ID installation manual

PROEL AE300 OPERATING AND INSTALLATION Manual

PROEL

PROEL AE300 OPERATING AND INSTALLATION Manual

NAPCO NETLINK datasheet

NAPCO

NAPCO NETLINK datasheet

Clover BUN 1460 Quick installation guide

Clover

Clover BUN 1460 Quick installation guide

Lorex SG15F6584 instruction manual

Lorex

Lorex SG15F6584 instruction manual

Honeywell X-618 installation manual

Honeywell

Honeywell X-618 installation manual

Visonic PowerMaster-33 G2 Installer's guide

Visonic

Visonic PowerMaster-33 G2 Installer's guide

Cisco Codec C Series Getting started guide

Cisco

Cisco Codec C Series Getting started guide

Pyronix Enforcer 32WE Setup guide

Pyronix

Pyronix Enforcer 32WE Setup guide

Q-See QS458-811-5 manual

Q-See

Q-See QS458-811-5 manual

DesignTech Smart Entry 20083 / 25583 installation manual

DesignTech

DesignTech Smart Entry 20083 / 25583 installation manual

Swann SwannSecure instruction manual

Swann

Swann SwannSecure instruction manual

jablotron JA-10 Series manual

jablotron

jablotron JA-10 Series manual

Prestige APS-596E owner's guide

Prestige

Prestige APS-596E owner's guide

R.W. BECKETT GENISYS 52040 installation instructions

R.W. BECKETT

R.W. BECKETT GENISYS 52040 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.