ABuilding Safety. Building Security.
Multi Module
MEA244-1
Description
• ADM loop technology with
System Sensor/200 protocol
• 4 independent line-monitored inputs
• 4 independent outputs with patented
monitoring of line resistance and
load resistance
• Optimized for use in extinguishing
systems
• Supply supervised for undervoltage
The Multi Module MEA244-1 has been designed espe-
cially for use in extinguishing systems. It has 4 indepen-
dent inputs for connection of contact detectors, and 4
independent, powerful outputs for actuation of external
control devices.
The inputs are monitored to detect wire breakages and
short circuits of the connection leads. On the outputs
the internal resistances of the control devices and the
line resistances are monitored separately. An automatic
calibration procedure, which gets started by pressing
a key during commissioning, determines the reference
values of both resistances. The patented method of
multiple monitoring makes the reliable detection of line
or load faults as well as contact corrosion possible.
The multi module is used as loop element with inte-
grated dual-isolator, in an ADM loop with System Sen-
sor/200 protocol. The module occupies 8 consecutive
addresses on the ADM loop. During commissioning, the
base address, which is assigned to input 1, gets ente-
red using a key, all further addresses are automatically
assigned by the module.
The MEA244-1 and the connected control devices are
supplied through an external 24V power supply. The
supply voltage gets supervised for undervoltages. If the
voltage drops below the threshold of the undervoltage
detection, then this event is automatically signalled to
the control panel, via the loop, as fault of all four out-
puts. Each input and each output has a status LED.
The multi module is available in two versions:
• The MEA244-1/TR has been designed for mounting
on a DIN rail,
• the MEA244-1/E can be mounted in a control panel
using the supplied mounting spacers.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
MEA244-1_DBL_LST_EN_0823.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Supply voltage 20 to 30VDC
Threshold of undervoltage detection 21.7V (can be increased to 25.3V by using a jumper)
Current consumption at 24V 35mA (quiescent)/max. 160mA (without load)
Current consumption on the loop 500µA
Number of inputs / outputs 4 / 4
Load current per output max. 1.5A
Ambient temperature MEA244-1 -5°C to +60°C
Ambient temperature external control equipment +5°C to +50°C (to ensure the functioning of the fault detection)
Patent number AT 501 215 B1
Approval VdS G205120
Multi module for mounting on rail
Dimensions L × W × H 196 × 97 × 56 (mm)
Weight 310g
Order number 249092
Order name Multi Module/Mounting Rail MEA244-1/TR
Multi module for mounting in control panel
Dimensions L × W × H 194 × 93 × 20 (mm)
Weight 150g
Order number 249095
Order name Multi Module/Panel Mounting MEA244-1/E

This manual suits for next models

1

Other LST Security System manuals

LST 55100-908 User manual

LST

LST 55100-908 User manual

LST PA58-3 User manual

LST

LST PA58-3 User manual

LST Vds 245302 User manual

LST

LST Vds 245302 User manual

LST SZ58-3 User manual

LST

LST SZ58-3 User manual

LST Serial Interface Module SIM06-1 User manual

LST

LST Serial Interface Module SIM06-1 User manual

Popular Security System manuals by other brands

Honeywell ADEMCO VISTA-10P Installation supplement

Honeywell

Honeywell ADEMCO VISTA-10P Installation supplement

netvox RA02G user manual

netvox

netvox RA02G user manual

Bentel Security LADY-PI manual

Bentel Security

Bentel Security LADY-PI manual

DS Produkte MD-328J instructions

DS Produkte

DS Produkte MD-328J instructions

Honeywell LYNX quick guide

Honeywell

Honeywell LYNX quick guide

Voyager WVRXCAM1 Wvrxcam

Voyager

Voyager WVRXCAM1 Wvrxcam

Compound Security Systems Mosquito MK4 ADDITIONAL SETUP INSTRUCTIONS

Compound Security Systems

Compound Security Systems Mosquito MK4 ADDITIONAL SETUP INSTRUCTIONS

Abibird Abibird user guide

Abibird

Abibird Abibird user guide

AMS CO-ALARM S/200-C Installation and operating instructions

AMS

AMS CO-ALARM S/200-C Installation and operating instructions

WataSensor WALERT user manual

WataSensor

WataSensor WALERT user manual

System Sensor PS24LO Installation and maintenance instructions

System Sensor

System Sensor PS24LO Installation and maintenance instructions

Steren CCTV-2000 user manual

Steren

Steren CCTV-2000 user manual

Thitronik WiPro III installation manual

Thitronik

Thitronik WiPro III installation manual

Eminent EM8610 user manual

Eminent

Eminent EM8610 user manual

KATEK TeleAlarm EV-04 quick start guide

KATEK

KATEK TeleAlarm EV-04 quick start guide

Aruba LS-BT20 installation guide

Aruba

Aruba LS-BT20 installation guide

Karassn KS-858G user manual

Karassn

Karassn KS-858G user manual

3M 501 Operator instructions

3M

3M 501 Operator instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.