Installaon and Operang Instrucons CHM
Wall mounng
Feel good through warmth from electricity - www.technotherm.de
GB
7. Guideline
Informaon requirements for electrical room heaters
Type: CHM DSM (oponal with the DSM interface)
Designaon Symbol Rate Unit Designaon Unit
Heang capacity Type of heat supply, only for electrical storage heaters in rooms (select one type)
Nominal thermal
output Pnom 0.5 1.0 1.2 1.5 1.8 2.0 kW Manual thermal charge control, with integrated thermostat NO
Minimal thermal
output (indicave) Pmin 0.5 1.0 1.2 1.5 1.8 2.0 kW Manual thermal charge control with acknowledgement of the
room inside and /or outside temperature
NO
Maximum con-
nuous thermal
performance
Pmax,c 0.5 1.0 1.2 1.5 1.8 2.0 kW
Electronic charge control with acknowledgement of the room
inside and /or outside temperature
NO
Auxiliary current
consumpon
Heang power supported with a fan NO
At nominal thermal
output elmax 0.5 1.0 1.2 1.5 1.8 2.0 kW Type of heang power / room temperature Control (select one
type)
At the minimum
heang capacity elmin 0.8 0.8 0.8 0.8 0.8 0.8 Wa Single-stage heang capacity; no room temperature control NO
At the standby
mode elSB 0.8 0.8 0.8 0.8 0.8 0.8 Wa Two or more manual stages, no room temperature control NO
With mechanical room temperature control NO
With electronic room temperature control NO
Electronic temperature control in the room, depending on the
me of day
NO
Electronic temperature control in the room, depending on the
weekday
YES
Other control opons (mulple choice is possible)
Room temperature control with presence detecon NO
Room temperature control with detecon of an opened window YES
With remote control opon NO
With adapve start control YES
With limitaon of heang me NO
With a black lamp sensor NO
Contact Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt, Germany
Type: CHM RF (addional thermostat TPF-Eco and Eco interface is required
Designaon Sym-
bol Rate Unit Designaon Unit
Heang capacity Type of heat supply, only for electrical storage heaters in rooms (select one
type)
Nominal thermal
output Pnom 0.5 1.0 1.2 1.5 1.8 2.0 kW Manual thermal charge control, with integrated thermostat NO
Minimal thermal
output (indicave) Pmin 0.5 1.0 1.2 1.5 1.8 2.0 kW Manual thermal charge control with acknowledgement of the
room inside and /or outside temperature
NO
Maximum con-
nuous thermal
performance
Pmax,c 0.5 1.0 1.2 1.5 1.8 2.0 kW
Electronic charge control with acknowledgement of the room
inside and /or outside temperature
NO
Auxiliary current
consumpon
Heang power supported with a fan NO
At nominal thermal
output elmax 0.5 1.0 1.2 1.5 1.8 2.0 kW Type of heang power / room temperature Control (select
one type)
At the minimum
heang capacity elmin 2 2 2 2 2 2 WSingle-stage heang capacity; no room temperature control NO
At the standby
mode elSB 0.47 0.47 0.47 0.47 0.47 0.47 WTwo or more manual stages, no room temperature control NO
With mechanical room temperature control NO
With electronic room temperature control NO
Electronic temperature control in the room, depending on
the me of day
NO
Electronic temperature control in the room, depending on
the weekday
YES
Other control opons (mulple choice is possible)
Room temperature control with presence detecon NO
Room temperature control with detecon of an opened
window
NO
With remote control opon YES
With adapve start control NO
With limitaon of heang me NO
With a black lamp sensor NO
Contact Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt, Germany