lumishore Eclipse SMX93 User manual

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
1
45-0204-Rev1
Voltage
10-31V DC
Color Output
Color change
Please read the following pages before attempting installation to ensure complete understanding of
Lumishore ECLIPSE SMX93. This product should only be installed, inspected, and maintained by a qualied
electrician only, in accordance with all applicable electrical codes. Be certain electrical power is OFF before
and during installation and maintenance.
Before you start:
• Always ensure that the vessel’s power source and baery are disconnected or isolated prior to installaon.
• A qualied professional should carry out both the electrical and mechanical installaon.
• For best underwater illuminaon, LUMISHORE recommends installaon 4” to 12” (100-300mm) below the
minimum load water line.
• Choose a locaon - The light must be mounted on a at (not curved) surface. For underwater installs mount
on transom or side hull only.
• A hole will be drilled to allow the cable to be inserted; care must be taken to ensure there is unrestricted
access inside the hull.
• When installing three or more lights, equal spacing 2.5’- 3’ is recommended to give a consistent light pool.
• The light is temperature sensive and must not be located close to the exhaust outlet or other heat source.
• SMX93 Lights operate on 12V or 24V DC. Never connect a light directly to the mains AC voltage, or DC voltage
other than that specied.
• For Installaon on boats up to 7.5m (25 ). Isolaon kit (39-0203) MUST be used on boats with conducve
hulls.
eclipse SMX93 Color Select Installation Manual
60-0315 - SMX93 - Color Select

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
2
Mechanical installaon
Tools: Drill, drill bits, marine sealant (3M 4200, or equivalent),F2 Frearson type screwdriver, Flat head screw
driver, cloth for clean-up:
Pilot Hole for Screws - 9/64” / 3.5mm
Hole for Cable - 9/32” / 7mm
Recess for Gland - 17/32” / 13.5mm hole to a depth of 5/8” / 15mm
1. Select a suitable at surface that is accessible from behind and ensure the cable can be run without a
problem.
2. With one hole at the boom center, mark and drill the pilot holes for the screws & drill a ø4mm
counter bore to a depth of 5mm in each locaon. Drill the power cable hole. The cable hole must be
recessed on the outside of the hull to accept the cable gland on the back of the light, so that the lights
sits ush.
Note: Cored hulls must be sealed prior to ng the lights - refer to the manufacturers instrucons.
3. Clean and prepare the hull ready for the sealant.
Rear side
Basic Dimensions
Apply sealant
Boom center
70 mm (2.75in)
17mm (0.67in)
12mm
(0.47in)
PCD 61mm
(2.40in)
120°

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
3
4. Apply a connuous thick bead of sealant to the back of the light, making sure the recess on the outer
edge is slightly overlled. Also apply a bead of sealant around the cable gland. Refer to image above.
5. Push the power cable through the hole and align the light with the pilot hole screws.
6. Aach the light using the 3 supplied screws by hand ghtening with a screwdriver.
IMPORTANT: Do not over ghten. Do not use power tools to ghten screws.
7. Use a damp cloth to wipe o excess sealant that has squeezed out around the light. DO NOT use
chemical cleaners or solvents.
IMPORTANT: Refer to the direcons on the sealant to make sure it has fully cured before
launching the boat into the water.

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
4
Installaon diagram - Single switch
Plan the cable route prior to installaon. Ensure all cables are suitable for marine applicaons, and
correctly rated for the required voltage and current. Each light must be individually fused. The cable
connecons are:
Red 12V or 24V DC
Black Ground
Fuse rangs: 12V DC 4A
24V DC 3A
An ON / OFF switch should be installed to select the modes of operaon. All connecons must be made
waterproof.
Fuse or
Circui t
Breaker
Batter y
Red
(+VDC)
Red
(+VDC)
Black
(GND)
Fuse
Fuse
Switch
On
Use correct cable gauge -
consult ABYC recomendations
for MAX 3% voltage drop

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
5
Switch operaon
The lights operate in a preset color cycle, always starng in white, The lights then go into a color cycle. The
lights can be paused on any color in the cycle. To do this turn the switch OFF / ON (wait a second before
switching back on). Switch OFF / ON to restart the color cycle. To reset to white, switch the lights o for 5
seconds, and then back on.
R
E
D
G
R
E
E
N
B
L
U
E
W
H
I
T
E
O/On to Pause
O/On to Resume
S
w
i
t
c
h
i
n
g
O
N
S
t
a
r
t
s
h
e
r
e
Installaon Diagram - Eclipse Command Center
Note: For full ECLIPSE Command Center control consult ECLIPSE Command Center installaon manual
Cut the cable just below the
heat shrink. Remove the outer
insula�on to reveal the yellow
wire
Before connuing ensure the Yellow wire from the light has been exposed (see below)

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
6
Up to 2 lights per Command Center
RED
BLK
YEL
RED
WHT
BLU
YEL
RED
BLK
YEL
ECLIPSE Command Center
CONNECT AS BELOW;
ECLIPSE cable harness RED to SMX93 RED
ECLIPSE cable harness YEL to SMX93 YEL
ECLIPSE cable harness WHT & BLU to SMX93 BLK
ECLIPSE Cable
Harness
10 - 15V
Select and install appropriate
blade fuse for complete circuit
Electrical installaon - ECLIPSE Command Center
Important! The ECLIPSE Command Center
installation is suitable for 12V boats ONLY.
More than 2 lights per Command Center
YEL YEL YEL YEL YEL
RED to +10 - 31V
Fuse Fuse Fuse Fuse Fuse
RED to +10 - 31V RED to +10 - 31V RED to +10 - 31V RED to +10 - 31V
BLK to GND BLK to GND BLK to GND BLK to GND BLK to GND
ECLIPSE Command Center
CONNECT AS BELOW;
ECLIPSE cable harness YEL to SMX93 YEL
SMX93 RED to +10-31V (Individually fused)
SMX93 BLK to GND
ECLIPSE Cable
Harness
RED, WHT & BLU - No connect.
Ensure any unused wires are isolated.

| + 44(0)208 144 1694 | Info@Lumishore.com
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | Sales@LumishoreUSA.com
Lumishore UK, Unit D12, Upper Fforest Way, Swansea Enterprise Park, Swansea, SA6 8QR
7
Cleaning and maintenance
LUMISHORE lights require simple cleaning. Lights should be checked oen to ensure the light body and lens
area are free from sea growth. In the event that your light requires cleaning, we recommend the use of a
so cloth or so bristled brush.
• DO NOT use any abrasive cleaning materials as these may damage the body of the light.
• DO NOT use any cleaning uids that contain solvents, acids or alkali’s.
• DO NOT clean using pressure washing or sandblasng equipment.
Slight discoloraon of body may occur over life. This does not aect performance, and is not subject to
warranty.
Due to nature and high build quality it may on rare occasions be possible to see small levels of condensa-
on, this is normal for high power LEDs and will disappear aer cooling and does not harm operaon in any
way.
If the lens of the light is covered for any reason, e.g. maintenance, or painng DO NOT switch the lights on
unl the covers are removed.
Warranty
LUMISHORE Ltd warrants the SMX93 to be free from defects in workmanship and materials for a period of
two years, starng from the date of original purchase. Misuse, abuse, improper installaon, neglect, im-
proper shipping, damage caused by disasters such as re, ood, and lightning, installaon by unqualied
personnel, unauthorized repair or modicaon will void this warranty. For the avoidance of confusion and
doubt, non-compliance with all installaon, maintenance and operang instrucons in this document con-
stute non-conformance with warranty terms.
This manual suits for next models
1
Table of contents
Other lumishore Lighting Equipment manuals

lumishore
lumishore Eclipse SMX23 User manual

lumishore
lumishore eclipse SMX94 User manual

lumishore
lumishore LUX SNL 180 User manual

lumishore
lumishore LUX Livewell Light LW25 User manual

lumishore
lumishore LUX Flood Light 18" User manual

lumishore
lumishore Curved 20 User manual

lumishore
lumishore EOS Lumi-Link Blackbox User manual

lumishore
lumishore LUX Strip Light SL180 User manual

lumishore
lumishore eclipse SMX53 User manual

lumishore
lumishore eclipse CL30 User manual