LVI Touch E3 User manual

1|
INSTALLATION AND OPERATING MANUAL
The Touch E3 can control certain LVI devices, please see each device´s
instruction manual.
MANUEL D'INSTALLATION ET D'UTILISATION
Le Touch E3 peut contrôler certains appareils LVI, consultez le manuel
d’utilisation de chaque appareil pour plus d’informations.
GB
FR
TOUCH E3


P16MI417 - A02 - 01/16 3|
FOR THE INSTALLER
INSTALLATION OF THE TOUCH SCREEN
01. Main characteristics
• Touch screen (4 inches)
• Interface via internet.WiFi 2.4 GHz (not 5.0 GHz)
• Wall mountable with power supply 85-265V (50-60)Hz
• Can be placed on the table with supplied bracket,and mini USB power supply (5V).
• Battery operation (only for settings)
• RF Communication with other devices
• Multiple heating device control.
• SD Card update
• Intuitive menus for device management
! Charge the Touch E3 for at least one hour before pairing the devices
already mounted.
02. Available devices for connecting to Touch E3 (For example: Yali Digital,
Parada and Ramo)
• Up to 50 rooms (zones) with one master radiator in each room.
• Up to 50 slave radiators to be distributed among the masters.
Examples: a) 50 zones with 1 master and 1 slave in each, total 100 radiators
b) 1 zone with 1 master and 50 slaves, total 51 radiators.
It is recommended to limit the number of slaves to 10 in one zone.
FOR
THE INSTALLER UK

| 4 P16MI417 - A02 - 01/16
FOR
THE INSTALLER
UK
03. Wall mounting
• Connect the power supply as described below. The electrical installation
must comply with local or national regulations. The product should be
connectedbyasuitableandqualiedelectrician.
TEMP. PRECISION: 0.1°C
ENVIRONMENTAL
CONDITIONS:
- Operating temperature
- Shipping and storage temp.
-0°C to +40°C
-30°C to +50°C
SETTING TEMPERATURE
RANGE:
- Comfort mode
- Reduced mode
- Frost protection mode
+5.5°C to +30°C, must be higher than the reduced mode temperature.
+5°C to +19°C, must be lower than Comfort mode temperature.
+0.5°C to +10°C
ELECTRICAL INSULATION: Class II
ELECTRICAL PROTECTION: IP 30
RADIO FREQUENCY:
- Range outside
- Range indoor (typical)
868 MHz, <10mW
200 m
Around 15 m
WIFI FREQUENCY:
2.4 GHz (not 5.0 GHz). Touch E3 supports the following standards:
- 802.11b at 2.4Ghz- 802.11g mixed 5GHz / 2.4GHz
Note that if your router is set to this standard ‘802.11g mixed
5ghz / 2.4GHz’ then it is mandatory to select the type of Key
to ‘WPA/WP2 mixed’ in order to connect in 2.4GHz with the
Microchip 2.4GHz WiFi module.
SOFTWARE VERSION Can be found at the bottom of the Main menu: xx.xx
CanbefoundatthebottomrightoftheWimenu:xxxxxx.xx
POWER SUPPLY 85-265V 50-60 Hz
CE DIRECTIVES:
Your product has been
designed in conformity with
the European Directives.
LV Directive 2006/95/EC
EMC Directive 2004/108/EC
R&TTE Directive 1999/5/EC
RoHS 2011/65/EU
POWER SUPPLY 85-265V, 50/60 HZ
NOT TO BE USED!

P16MI417 - A02 - 01/16 5|
• Screw the power supply on to the wall.
NOTE: The tab must be located at the top.
• Put the switch into the ON position by using a small pin
• Connect the mini USB cable and charger to the Touch E3.
• Mount the Touch E3 onto the bracket by sliding it down until it stops.
• Put the switch into the ON position by using a small pin
• The Touch E3 is now ready for use.
• Mount the Touch E3 on the power supply and slide it down until it stops.
• The Touch E3 is now ready for use.
04. Table installation
60 MM
ON / OFF
ON / OFF
CABLE
FOR
THE INSTALLER UK

| 6 P16MI417 - A02 - 01/16
05. General pictograms
SETTING LANGUAGE, TIME AND DATE
01. Press “Main menu” button A
02. Press “Set language” button D
•Theagofthecurrentlanguageisdisplayed.
03. Press “User settings” button F
• Set the current time and date
to return to the “Start screen”
to return to the previous screen
the buttons with a red dot require a long press
FOR
THE INSTALLER
UK
MAIN MENU
BUTTON
START SCREEN
SET LANGUAGE
USER SETTINGS PARAMETER SETTINGS
AB
MAIN MENU
C
F
D
G
E
H I

P16MI417 - A02 - 01/16 7|
CREATE HOUSE
01. Press “Main menu” button A
02. Press the “Parameter settings” button I (long press)
03. Press the “House creation” button
• Create all the rooms (or zones)
a Current room name
bTo change the current room name
c To add a room
dTo delete the current room
e Room selection
PAIRING RADIATORS
01. Press “Main menu” button A
02. Press the “Parameter setting” button I (long press)
• >> Select radio pairing
• Choose device, press “Heating”.
• Select room
FOR
THE INSTALLER UK
a
b
c
e e
d
RADIO PAIRING
ROOM MENU

| 8 P16MI417 - A02 - 01/16
• Start the pairing by pressing“radio pairing” button f
• Follow the instruction on the screen (depending on the type of device) .
• Repeat the steps for all devices, starting at >> Select radio pairing
•Press“Greencheck”buttontoconrm
• Device (Radiator or Remote Control) to measure the temperature
must be paired first in this zone!
•Press“Greencheck”buttontoconrm
03. Put the device (radiator or remote control) in pairing mode.
•Seedeviceleaetormanual
EXAMPLE: YALI DIGITAL /P/R
Press and hold the “OK” key for 5 seconds
rFi: Wireless Radio initialization (pairing)
Press “OK”to enter this initialization sequence.
Select with“+”or “-”the radio communication type and validate by pressing “OK”:
• rF.un: unidirectional communication, the digital thermostat only receives
orders from an LVI RF central programmer.
•rF.bi: bidirectional communication with an LVI Touch E3. The digital
thermostat communicates state and power consumptions to the LVI Touch E3.
Then the backlight will switch off and the digits will cycle showing that
the digital thermostat is waiting for a radio link signal from a Central
programmer or LVI Touch E3 to be received (press “”to cancel radio
initialization).When the radio link signal is received, pairing is saved,
then it will return to Auto mode.
FOR
THE INSTALLER
UK
RADIO PAIRING
BUTTON
f

P16MI417 - A02 - 01/16 9|
FOR
THE INSTALLER UK
When you have completed the pairing of all devices and each device is
installed in its final location, check that communication is established
between each device and the Central Unit.
Before checking, install the Central Unit in its final location. Checking
is undertaken by adjusting the heating mode or the set point on the
Central Unit and confirming that that the adjustment instruction has
been received by the Thermostat and the Receiver

| 10 P16MI417 - A02 - 01/16
04. Installation types (Type 1)
FOR
THE INSTALLER
UK
TOUCH E3
MASTER
SLAVE 1
SLAVE 2

P16MI417 - A02 - 01/16 11 |
05. Installation types (Type 2)
FOR
THE INSTALLER UK
TOUCH E3
SLAVE 2
SLAVE 1
(LVI RADIATOR)
(LVI RADIATOR)
MASTER

| 12 P16MI417 - A02 - 01/16
FOR THE INSTALLER
AND USERS
DEFINE A MODE TO A ZONE/ROOM
01. From the “Start screen”, press “Home” button. B
02. Press “Current mode” button 3 . (See“Heating Device Management”section, p 18).
Showinganti-freezemodethersttime.
g Comfort mode:
Set the comfort temperature in this mode.The radiator will remain at this
temperature.
h Auto mode: The room temperature will follow the selected program.
i Reduced mode:
Set the reduced temperature in this mode.The radiator will remain at this
temperature.
j Timer mode
•Todenethetime,pressthe“Blackhourglass”button.
•Denethetime(3minutes-44days)
• Press the “Green check” button
• Press the “White hour glass”button
• Press the “Green check” button
•Dene“timertemperature”bypressing“+”or“-”intheControlmenu.
k Frost protection mode.
Set the Frost protection temperature in this mode.The radiator will remain
at this temperature.
l Off mode.
The radiators will not heat. NOTE: Your house’s water pipes may freeze in this
mode. WARNING: The radiators are still connected to the electrical supply.
m Program Setting: For selecting the program to be followed when in Auto mode.
03. Press the desired mode button
04. Press the “Green check” button
FOR THE INSTALLER
AND USERS
UK
g h
m
i j k l CURRENT MODE
MENU

P16MI417 - A02 - 01/16 13 |
DEFINING TEMPERATURES FOR EACH ZONE, BOTH FOR
COMFORT AND REDUCED MODE.
01. From the “Start screen”, press “Home” button. B
02. >> Press “Current mode” button 3 . (See“Heating Device Management”section,p 18).
03. Press the “Comfort” or “Reduced” button
04. Press “Green check” button to confirm
05. Press “+” or “–” to set the temperature
06. Press “Heating”button 1 to save the temperature
07. Press the arrows 2 to change room. Or press button 9 to see all rooms.
Repeat from >> 02.
DEFINE WEEKLY PROGRAM FOR EACH ROOM
You have the possibility to SELECTapre-denedprogram,CREATE a new program
or EDIT (make small changes) to a program you have created yourself.
TO SELECT
01. From the “Start screen”, press “Home” button. B
02. Press the arrows 2 to change room. Or press button 9 to see all rooms.
03. Press “Current mode” button 3 . (See“Heating Device Management”section,p 18).
04. Press “Program Setting” button m
05. Press “Select” to choose any of the stored programs. There are 5 pre-defined
programs available.
06. Press “Green check” button to select a program
07. Warning sign, press”Green check” button.
08. Press the “back” button
09. Press the “clock” button
10. Press “Green check” button.
TO CREATE
01. From the “Start screen”, press “Home” button. B
02. Press the arrows 2 to change room. Or press button 9 to see all rooms.
03. Press “Current mode” button 3 . (See“Heating Device Management”section,p 18).
04. Press “Program Setting” button m
05. Press “Create” to define your own program.
06. >> Select the days that you want to program in the same way. When a day is:
• Red, it is not programmed
• Grey, currently selected for programming
• Green, it is programmed
FOR THE INSTALLER
AND USERS UK

| 14 P16MI417 - A02 - 01/16
FOR THE INSTALLER
AND USERS
UK
FOR EDIT
01. From the “Start screen”, press “Home” button. B
02. Press “Current mode” button 3 . (See“Heating Device Management”section, p 18).
03. Press “Program Setting” button m
04. >> To edit a created program, press “Edit” button.
05. Select the day you want to change.
06. Do the change.
07. Press “Green check” button.
08. Warning sign, press "Green check" button. If desired, repeat from >> 04.
09. Press the “back” button
10. Press the “clock” button
11. Press “Green check” button to confirm.
07. Initially, the reduced mode is set for 24h (15 minute periods). Press the
“Comfort” or “Reduced” buttons to create the program. The cursor can
also be moved by pressing the arrow buttons 2 .
08. Press “Green check” button to confirm these days and repeat until all days are
green >> 05.
09. Once all the days are green, press the “Green check” button.
10. Warning sign, press “Green check” button.
11. Press the “back” button
12. Press the “clock” button
13. Press “Green check” button to confirm.

P16MI417 - A02 - 01/16 15 |
FOR
USERS UK
FOR USERS
K Day and date
L Displays either time or temperature of a selected room. Change by pressing
temp/time value in the center of the screen and then choose which room's
temperature you want to display.
M Screen lock. Press on the icon and enter the default code “1066” or enter the code
youhaveconguredinInstallationmenu>> Screen lock.
N Error indicator, only visible when active. Access the list by pressing the icon.
O Powered by battery, only visible when disconnected.Touch E3 should be
connected to a power supply during normal use.
BHouse/Rooms access (only possible to view, not to change the settings when
the screen is locked)
P Holiday mode, only visible when active.
A To access“Main menu”
C Consumption statistics menu
• Press “heating”
- Check current or previous consumption period for the whole installation or
by room, per day/week/month/year.
• To present the information graphically, press the “information button”
• To delete history, press the “trash can” button (long press).
K
L M
N OBA
P START UP
SCREEN
MAIN MENU
C
F
D
G
E
H I

| 16 P16MI417 - A02 - 01/16
D Languagesetting.Theagofthecurrentlanguageisdisplayed.
E Mode menu
• Use this menu to set all radiators in the house to the same mode.
• Press button n until desired mode appears (An “empty button”means that
different zones could be in different modes).
• Press the “Green check”button. It will take a few minutes before all units
have received the new information.
F User settings
• In this menu, it is possible to set
- Date and time
- Summer -Winter time settings
- Temperature and time units.
- Background Colour
- Buttons colour
- Backlight
- Screen
- Reset User settings to factory settings.
G WiFi.
• If button is grey, wait until it is coloured. Press the button and you may read
the IP-address when the unit is connected to the internet via a WiFi-router and
the units MAC address.When you pair the Touch E3 to a server, you should
type password you receive by mail in “internet access password”.
See also “WiFi settings” section, page 21.
HHoliday mode
•Denetimeanddateofdeparture
FOR
USERS
UK
n
MODE MENU
INFORMATION
CONSUMPTION
STATISTICS MENU

P16MI417 - A02 - 01/16 17 |
I Installation (House creation menu)
• House creation (See “Create house” section, p 7)
• Radio pairing (See “pairing radiators” section, p 7)
• Screen lock (See“Other functions for the installer”section, p 19)
• Delete a device (See “Other functions for the installer”section, p 20)
• Delete all devices (See “Other functions for the installer”section, p 19)
• Identify a device (See “Other functions for the installer” section, p 19)
• Heating Settings (See “Other functions for the installer” section, p 20)
• WiFi settings (See “WiFi settings”section, p 21)
• General factory default (See “Other functions for the installer”section, p 20)
• Update Firmware (See “Other functions for the installer”section, p 20)
• Press the “Green check” button
•Denetimeanddateofreturn
• Press the “Green check” button
•Deneamodetowholeinstallation(SeeModemenu E ).
To cancel, press so the button is “empty”.
• Press the “Green check” button.
After the start or end time, it will
take a few minutes before all units
have received the new information.
FOR
USERS UK

| 18 P16MI417 - A02 - 01/16
HEATING DEVICE MANAGEMENT
1Heating button. Could be used for validation of temperature setting to
speed up the change.
2 Room selection
3 ”Current mode”, press to alter mode
4Set point temperature, or Ambient temperature value.
5 Press to toggle between values in point 4.
6Press to increase or decrease the setpoint. Does not need to be validated.
7 Heating indicator (animated when heating)
8 Current room name
9 Quick access to “Room menu”
10 Information button
11 Only displayed when screen is locked
12 Shows a“moon”symbol if radiator is in reduced mode by external signal.
FOR
USERS
UK
1
2 2 9
4
3 5
6
6
7
8
10
11
12 CONTROL MENU

P16MI417 - A02 - 01/16 19 |
FOR THE INSTALLER AND FOR
ADVANCED USERS
OTHER FUNCTIONS FOR THE INSTALLER
01. Press “Main menu” button A
02. Press the “Parameter setting” button I (long press)
03. Create house (See “Create house” section, p 7)
04. Radio pairing (See “pairing radiators” section, p 7)
05. To delete a device
• Press“Delete a device”button
• Press “heating”button
• Use the arrows to scroll through the list of paired devices.
• Select the device to be deleted
-Note:Tomakesurethattherightdeviceisdeleted,identifyitrst(Seebelow)
-Note:Iftherstdeviceinaroomisdeleted,alldevicesinthatroom
will be deleted.
•Press“Greencheck”buttontoconrm
06. To delete all devices
• Press“Delete all devices”button
•Press“Greencheck”buttontoconrm
• Press“Red cross”to decline
07. Identify a device and edit some device information; such as name, power,
surface temperature limitations and sequential mode.
• Press“Identify a device”button
• Press the “Radio button”
• Make the device send a radio message
- (On Yali, press OK and wait for the backlight to go off)
• Make a note of the ID-number that is displayed on 3rd line of the screen >>
• To be sure it is right, send a second radio message from the device and compare
the ID-number (it could happen that another device coincidently sends
a message at the same time, therefor it is good to repeat this operation).
FOR THE INSTALLER AND FOR
ADVANCED USERS UK

| 20 P16MI417 - A02 - 01/16
• If you want to edit device information/settings, press the button with a Red dot
(long Press):
- Device name,
- Power,
- Set front panel max surface temperature level.
> Press “Heating rate maximum level” rate.
>SelectP1,P2orP3.NOTE:therstpairedradiatormusthavethesame
or higher value than the rest of the radiators in the room, otherwise the energy
calculation will be wrong.
>Press“Greencheck”buttontoconrm.
- For double radiator, change to sequential control.
> Press “Sequential control”button
> Select “No”(default setting) if the radiator’s front and back panel should be
evenly heated.
> Select“Yes”if the radiator’s front and back panel should be heated sequentially.
>Press“Greencheck”buttontoconrm.
08. Screen lock
• Press “Screen lock” button
• Enter your personalized code (it must contain 4 characters)
•Press“Greencheck”buttontoconrm
Note: the default code is 1066
09. Heating settings
Set Minimum and Maximum allowed temperatures in each room.
• Press“Heating Settings” button
• Press a room button
10. WiFi settings (See “WiFi settings” section, p 21)
11. General factory default (all updates and user data will be erased except WiFi-
settings. They are reset under WiFi settings (See “WiFi settings” section, p 21)
by pressing the the Red “Reset” button (long press)
•Press“Greencheck”buttontoconrm
• Press“Red cross”to decline
12. Update firmware
•InsertSDcardwithnewrmware
•Press“Updatermware”
•Press“Greencheck”buttontoconrm
• Press“Red cross”to decline
Please wait until the end of the update procedure before removing the microSD from the Central
Unit.Theendoftheprocedureisdenotedbytheappearanceofthewi-buttonontheCentralUnit
FOR THE INSTALLER AND FOR
ADVANCED USERS
UK
Other manuals for Touch E3
2
Table of contents
Languages: