Dearusers,
Thankyouforhavingselectedtheintelligent alarmsystems. Pleaseread
throughthismanualbefore installation soas tooperateproperly.
Theintelligent alarmsystemadoptsthenewestGSMnetworkandDigital
SignalProcessingtechnology,andiswidelyusedinsecurityfields, suchas
protectyour home,store,office, factoryetc. It reallyrealizeswireless alarm
dealingandcontrollingremotely,convenientlyandflexible,and solvesthe
limitationofwireddatatransmissionintelephoneandwirednetwork.
Perfectstructure,convenientinstallation,easy operationwithwireless
remotecontrollersare designedfortheideaofpeople-oriented,whichwill
makeyoufeeleasy andcomfortablewhileusing this intelligentalarm
system.
Peopleiscenter,technologyisfirst”isourcompany’sactionrule.
CustomerSatisfactionisourconsistentpursuit. Perfectsystem,excellent
services, sincereattitudes will bringyouanewenjoyment.

Contents
1Description ..................................... 1
1.1 Mainfunctions.................................. 1
1.2Specification.................................. 2
2S tructure........................................ 3
3Installation and Operation........................... 6
3.1. Installing theSIMcard........................... 6
3.2Theconnection ofwired detectorsandspeaker.........6
3.3Running....................................... 7
4 . Pre-recordalarming voice.................... . ....... 7
5 . Programming by keyboard.......................... 8
5.1.Entering into settingstatus....................... 8
5.2.Programming mobilephonenumbersfor SMS alarm... 8
5.3.Programming phonenumbersfor voice callingalarm... 9
5.4. Modifying the passwordofalarmhost...............9
5.5.Modifying alarmhostID........................... 9
5.6.WhethersendSMSornotwhenarm/disarm.................. 10
5.7. Exiting settingstatus....................................... 10
6Programming by SMScommand................................. 10
6.1. Programming3 mobilephonenumbers forSMS alarm....... 10
6.2. Programming3 phonenumbers forvoice calling alarm........ 11
6.3. Deleting alarmphonenumbers.................... 11
6.4. Modifying thepasswordofalarmhost..................... 11
6.5. Arm/Disarm............................................... 1 1
6.6. Modifyingzones name.................................... 12
6.7. Modifying installation address name........................ 12
6.8. Inquiring arm/disarmstatus................................12

6.9. InquiringAC powerstatus ofalarmhost................... 12
6.10. Switchingover fourlanguages..............................13
6.11.Programming independentarm..................... ....... 13
6.12.Cancelindependentarm.................................... 13
7. Programmingby phonekeypadremotely......................... 14
8. Operating steps.................................................. 15
8.1.Arm/disarmby remote controller............................. 15
8.2.Emergencyalarm........................................... 15
8.3.AC powerfailurealarm...................................... 15
8.4. Handlingalarm............................................. 16
8.5.Arm/disarmandlisteninremotely........................... 16
9. Installationandoperationcautions............................... 17
10.Encode method.................................................. 18

1. Description
Thealarmsystemadopts SMSdatatransmissionandvoiceplatformof
GSMnetworktosendcontrolcommandandreceivealarm message
remotely. The systemcan be armed accordingto user’s requirements, when
asignalisdetectedby sensors,the sensors will sendalarmsignalto alarm
hostimmediately,thenthe alarm host will send alarmSMSto pre-set
mobilephonenumbers, and meanwhiledialsitspresettelephone/mobile
phonenumbersautomatically.Inaddition,usercandialthenumberinthe
alarm hosttoremotecontrolthehost, suchas arm,disarmetc.
1.1Mainfunctions
lWhethersendSMSornotwhenarm/disarm;
lArm/disarmremotelybyphone keypad;
lAutomaticallysendSMSto3 presetphonenumbers whilealarming;
lAutomaticallycall 3presetphonenumbers andstarton-sitelistenin
whilealarming;
lReal-timereport thealarmzoneremotelybySMSand voice
reminding;
lWithuser-friendlyvoice reminderwhileoperating the alarm host;
lSupporttwo-waycommunications;
lBuilt-in dedicatedemergencyalarmzoneandfirealarmzone;
lAutomaticallyreport whiletheACpowerfailedorrecovered and
switchtobackup batterywhentheexternalpowerfailure;
lBuilt-in 12 wireless alarmzones(including1 emergencyzoneand

1fire alarm zone), and 2 wired zones (with anti-cutfunction);
1.2Specification
1. Wireless frequency:315MHz/433MHz;
2. GSM frequency:900/1800/850/1900MHz
3. Alarmresponsetime: ≤8s (GSM signalin normal)
4. Powerrequirements:AC 220V50Hz/60Hz
Workingconsumption:< 0.6W
Backupbattery:DC7.4V/850MA
Backupbatteryworkinghours: ≥10 hours
5.Workingcondition
temperature: -20~+60℃humidity: ≤95% (non-condensation)
6.Size:150mm(L)×100mm(W)×16mm(H)
7. Recordtime:10s

2Structure
As shownabove:
1. Emergency button:usedforemergencyalarm
2. WIRLESS LEDindicator:when receivingwireless signalfrom wireless
sensoror remote controller, theLEDwill beon,otherwiseis off.
3. RUN LED indicator: blinking every2s whentheGSMsignalisnormal,
whentheGSM signalis failureit blinks every1s.
4. ALARM LED indicator: When thereisanalarmorenteringintosetting
status, itwill beon;whenthereisno alarm orescaping thesetting status, it
will be off.

5. Independentarm LED indicator: When thereisonezoneinthe
independentarmstatus, theLEDis on.
6. ARM LED indicator:Aftersystemarmed, it will beon;it will beoff
whendisarm.
7. Power LED indicator: External AC powerisconnected,theLEDis
on;external AC poweris failure, theLEDis off.
Shownas above:
1. Fixinghole: Use forfixingthealarmhost;

2. Powerswitch: Switchto rightison, Switchto leftisoff.
Shownas above:
1、SIM card socket
2、Learningbutton
3、Recordingbutton
4、Settingbutton
5、Siren socket
6、Powersupply socket

Shownas above:
1、RecordingMIC
2、ListeninMIC
3. Installation and operation
3.1、Installing theSIMcard
Thealarmhost transmits alarminformationby GSMSMS &voice
platform,soyoushouldprepareaSIMcardbeforetheinstallation.(If
youuseanewSIM card,you should checkthenewSIMcardcarefully
whether it cansendSMSand makecallsnormally ornot.)
Notes:Please turnoff thepowerbeforeinsertSIMcardandmakesure
thedirectionis correct.
3.2 The connection ofwired detectors and speaker
Thealarmhostisconfigured with 2 wiredalarmzones and

two-waycommunicationfunctions(bothwiredalarmzonewith
anti-cutfunction.)
Thewiring methodis as following:
1)After open thehost case withscrewdriver,youwill see6 wires insidethe
host. Shownas below:
Ofwhich:
Redwire:anodeoftheintercomspeaker;blackwire:thecathodeof
theintercomspeaker.
Bothyellowwires areforwiredzone1;
Bothgreenwires areforwiredzone2;
2)Drawoutthesewiresofwireddetectors &intercomspeakers from
thebackofthealarmhost(shownas following:

3.3、Startthealarmhost
Makesurethepowersupplywellconnection,switchon the
power;youwillsee thattheALARMindicatorlight,ARMindicator
light,POWERindicatorlightkeepbrightening,theRUNindicator
lightisblinking.After25s, thehostgetsintoinitialization&getsinto
thestatusofGSMnetworksearching,afterthatit will maketwo di
di”beepsoundsforconfirmation,thenthealarmsystemgetinto
normallyworking.Atthismoment,theAlarmindicatorlightandarm
indicatorlightwillbeoff, theRUNindicatorlightwill blink2s/time.
Notes:
If theRUNindicatorlightkeepsbrightening orkeepslightoff,it
means thatthealarmhosthas searchedtheGSM faults automatically.

4. Recordalarmvoicemessage
Press REC”button,during thehostworkingstatus, thehostwillmake
di ”sound,thenit beginsto10 secondsrecord.Itwill make di,di ”
soundsafterfinishing therecording.Ifyou’veconnectedtheintercom
speakerbefore,thehostwill broadcastyourrecordedmessage
automatically.
Note:Messageshouldbebrief.Forexample: ThisisNo.xx, buildingxx
districtxx. Pleasehelp, thereisillegalintrusioninthehouse.”
5. Programthehostbywireless controlkeypad
51. Getinto setting status
Duringthehost’srunningstatus, press set”button,it will maketwodidi
beepsounds, atthemeanwhiletheALARMLEDison.Itmeansthehost
entersintothesetting status. Thenyoucanstarttoprogramthealarm
numbers.
Note: Whensettingbythekeypad,everytimeyoupress thebuttonyou
will hear di”soundsforconfirmation, ifthere’s no voice you canpress
thebuttonagain.
Youcanpress this button *”(before pressing thebutton #”)to cancel
thenumbers thatyouhavealready input.
5.2 ProgramSMSalarmnumbers forreceiving SMSalarmmessage
a. Insettingstatus, operatethekeyboardas below

Input:Serialnumber+ mobilephonenumber+ #
Example: set13688888888 as thefirstSMSalarmphonenumber.
Input113688888888#, thenyouwill hear di, di ”soundsforconfirmation.
Repeattheprocess tosettheothertwomobilephonenumbers.
Note: serialnumbercanonlybe1,2,3 andthenumber 1”isthefirstSMS
alarmphonenumber, therestmaybededucedbyanalogy.
DeleteSMSalarmmobilephonenumbers
Input: serialnumber+ #, thencancancelthephonenumbers.
Note: Wesuggestyousettingthe firstSMSalarmmobilephone
number becausethatifyoudidnotsetthefirstsmsalarmnumber;you
will beunabletoknowwhether all ofthecontentsofthesettingare
rightornot.
5.3 Programming phone numbersforvoice calling alarm
Insetting status, input: Serialnumber+ phonenumber+ #
Example: Programphonenumber13688888888 asthefirstvoicecalling
number. Input413688888888#, thenyouwill hear di,di ”soundsfor
confirmation.
Repeattheprocess tosettheothertwophonenumbers.
Note: serialnumbercanonlybe4, 5, 6andthenumber 4”isthefirst
phonenumberforcall alarm,therestmaybededucedbyanalogy. Phone
number canbetelephoneormobile.
Deletephonenumbers forvoice callingalarm.
Input: serialnumber+ #, thencan cancelthephonenumbers.
5.4 Modifying thepasswordofalarmhost

Thefactorydefault passwordis 1234. Thepasswordmustbefourdigits.
Insetting status, theninput 7+newpassword+#”bywireless keypad,
youwillhear clicksoundsforconfirmation.
Example: set4321 asnewpassword,thenyoucaninput: 7+4321+#,you
will hear two didi ”confirmationsounds aftersetting successfully.
5.5 Modifying thealarmhostID
Thefactorydefault IDis 000000. Theserialnumbermustbesix digits.
Insettingstatus, theninput0 +sixdigitsofnewID+#, thehostwill make
asoundas di, di”toconfirmtheinput.
Example: set123456 asanewID,theninput: 0123456 #, aftersetting
successfully,youwill heretwodidiconfirmationsounds.
5.6 Whether sendSMSornot whenarm/disarm
Whenoperatethehostbyremotecontroller,ifyouwanttolethostsend
arm/disarm”SMStomobilephone,pleasefollowupthestepsasbelow.In
settingstatus, input 9+ # ”on wireless keyboard,thenyouwill hear di,di ”
soundforconfirmation.
Repeattheoperation,you cancancelthis function.
5.7 Exitsetting status, youwill receiveasetting message
Aftersuccessfullysetting,ifyou don’t’press any buttononwireless keypad
for15s,thealarmhostwill automatically exitsetting status. Atthismoment,
alarm indicatorlightwill beoff,andit will maketwo didi ”beepsounds,
thenthealarmhostwillsendoutasettingmessagetothefirstSMSalarm

number.
6. Programmingby SMS Command
6.1 Programming 3 mobilephonenumbers forSMS alarm
InputSMS:4digitspassword+DD +serialnumber+SMSalarmphone
number, thensendtoalarmhost.
Example:Thehost’spasswordis1234;set13888888888 asthefirstSMS
alarmphonenumber.
Send SMStoalarmhost: 1234DD113888888888
You will receiveasettingmessageaftersuccessfullysettingtheSMSalarm
mobilenumber.
Note: Theserialnumbershows alarmsequence (mustbe1, 2, 3)
6.2 Programming 3 phonenumbers forvoicecalling alarm
InputSMS:4digits password+DD +serialnumber+call alarmphone
number
Example:Thehost’spasswordis1234;set01088888888asthefirstcall
alarmphonenumber.
Send SMS:1234DD401088888888
Note: Theserialnumbershows alarmsequence (mustbe4, 5, 6)
6.3 Deletealarmphonenumbers
InputSMS:4 digitspassword+ DD + serialnumber
Example:Thehost’spasswordis1234. If youwanttodeletethefirstalarm
phonenumber,

Send SMS:1234DD1
Note: Theserialnumbershows alarmsequence (mustbe1, 2, 3, 4, 5, 6)
6.4 Changehost’s password
InputSMS:4 digitspassword+ DD + 7 + 4 digitsnewpassword
Example:Thehost’soriginalpasswordis1234. Ifyou wanttoset5678 as
newpassword
Send SMS:1234DD75678
Aftersettingsuccessfully,thenewpasswordwill besenttothefirstSMS
alarmphonenumber.
6.5 Arm/Disarmcommand
ArmbySMS:4 digitspassword+ A1
DisarmbySMS:4 digitspassword+ A2
Example:Thehost’spasswordis1234. Ifyouwanttosetthehostinarm
moderemotelycontrol, thenyoumaysendoneSMS:1234A1.
6.6 ChangeZone’sname
InputSMS:4digitspassword+DM+zone’scode(2digits)+Newzone’s
name
ReturnSMS:Newzone’s name.
Example:Thehost’spasswordis1234. If you wanttochangezone06’s
nameintoOurbedroomPIRAlarm.
Send SMS:1234DM06OurbedroomPIRAlarm.
Note:Changednameshouldbeless than 24 characters.
Zone’s codein2 digits:01 to11, ofwhich11 istheemergencyzone, and 12
is defaultas firealarmzone
6.7 Modify thenameoftheinstallationaddress

InputSMS: 4 digitspassword”+ DM00”+ userdefined name”
Aftermodifyingsuccessfully,themodifiednamewill besenttothepreset3
SMSalarmmobilephonenumbers.
6.8 Inquirehost’s arm/disarmstatus
Send SMS:4 digitspassword+ W1
ReturnSMS:Thehost’s arm/disarmstatus
6.9 Inquirehost’s externalpowerstatus.
InputSMS:4 digitspassword+ W2
ReturnSMS:host’s externalpowerstatus
6.10 4 Languages Switchover
InputSMS: 4 digitspassword”+ LG”+ series number”
Notes:Series numberstands for1.2.3.4, ofwhich1 stands forEnglish, 2
standsforChinese, 3 standsforRussian, 4 standsforSpanish
Aftersettingsuccessfully,youwill get3SMSreplyforswitchingtorelated
language.
6.11 Independentarm
Whentheindependentzoneinindependentarmstatus, onlySMScommand
cancontroltheindependentzone,doesn’tacceptanyother modes control.
Setalarmzoneastheindependentzone,inputSMS: 4digitspassword”+

AA”+”zoneseriesnumber”
Notes: zoneseriesnumber”standsfor10 zones (fromzone01 tozone10),
it’s allowtosetmulti-zones as independentzones.
Example:Ifyouwanttosetzone1, zone3, andzone4asindependent
zones, thehostpasswordis1234, thenyoucansend aSMStoalarmhost,
inputSMS:1234AA01, 03, 04
Notes:Betweeneachzone, youmustuseacomma , ”forseparating.
SMSreply:thestatusofeachzone,ofwhich A”stands forthezonehas
beeninstatusofindependentzone.
6.12 Cancelindependentarm
Whentheindependentzoneintheindependentarmstatus, onlySMS
command cancontroltheindependentzone,doesn’tacceptany othermodes
control.SowecanuseSMStocanceltheindependentarm, SMSinput:
4 digits password”+”AD”+ Zoneseries number”
Notes:Thezoneseriesnumberstandsfor10 zones (fromzone01 tozone
10), youcancancelmulti-independentzonesonetime.
Example:If you wanttocancelindependentzone1, zone3, zone4, the
passwordis 1234, thenyoumaysendSMStoalarmhost: 1234AD01,03,04
Pleaserememberthatyoushoulduseacomma ,”forseparating eachzone.

7. Remotecontrolalarmhostby phone
You canuseanytelephoneormobilephonetodialthephonenumberofthe
host, thehostwill automaticallygetthrough after15 secondsdetectingand
remindyou ofinputtingpasswordwithvoice.If theenteredpasswordis
wrongfor3 times, thehostwill handupthephoneautomatically;ifthe
enteringpasswordis correct,you will hear voice reminder, Press onearm,
press twodisarm”. Meanwhile, remotemonitoringwill runautomatically.
Press *”, you will hear di, di”sounds fromhosttoindicateit enteredinto
settingStatus, thenyoucancontinuethefollowingsteps
Note: Everytimewhenyoupress thephonekeyboard,thehostwill
makeclicksounds.Ifnot,thismeansyouroperationisunsuccessful,
youshouldpress itagain.
Youcanpress *”tocancelthenumberswhichyouhavealready
inputted(beforepress #”).
(1). Programmobilephonenumbers forSMSalarm
(2). Programmobilephoneortelephonenumbers foralarmcall
(3). Modifypasswordofthehost
(4). ModifynewIDofthehost
(5). Setalarmhostwhetherreply armordisarm”SMSornot
(6). Chooseopen/closealarmofhardwirezonecontact
(7). Exit settingstatusofthehost
Thesettingstepsbyphonearethesameas bywireless keyboard.Pleasedo
as correspondingoperationmethodbywireless keyboard.
8. Usage
8.1 Arm/disarmedby remotecontroller
a. Press thebutton ” on the remote controller, thehostmakes di”sound
and theLOCALLEDandREMOTE LEDaretwinkling.30 seconds later
thehostenters intoarmmodeandtheLOCALLEDand REMOTE LEDare
Table of contents
Other LY-TECH Security System manuals
Popular Security System manuals by other brands

Telguard
Telguard T-1630M Classic Quick installation guide

LG
LG IrisAccess iCAM4100 quick start guide

Meraki
Meraki MX84-HW installation guide

Bosch
Bosch VSS7902/00T Installation and operational manual

Honeywell Home
Honeywell Home Touchscreen 6290W installation guide

Visonic
Visonic SR-730 PG2 - installation instructions