BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Totalized pulse input module ........................................... (1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT INSERTION/REMOVAL OF MODULES
• Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches while the power is supplied.
The switches are used only for maintenance without the
power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R5-BS).
TOTALIZED PULSE INPUT MODULE
(Pi 2 points) MODEL R5-PA2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6139 Rev.2 P. 1 / 3
INSTRUCTION MANUAL
COMPONENT IDENTIFICATION
Euro Type
Connector Terminals
456
123
ON
1
Counter
Reset
2345678
1
2
RUN
3
4
Status Indicator LED
RUN LED
Counter Reset SW is normally OFF during operation.
■
SIDE VIEW ■FRONT VIEW
Note 1: Counter Reset SW is normally OFF during operation.
Note 2: Be sure to set unused SW1 through 7 to OFF.
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
Input status indicator: Red LED; turns on with the inputs supplied.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R5CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Span 100 to 60000 10000
R5-PA2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6139 Rev.2 P. 2 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
456
123
6.5
(.26)
90 (3.54) LOCKING CLAMP
90 (3.54) 5.6
(.22)
18 (.71)
POSITIONING GUIDE
■CONNECTION DIAGRAM
BUS CONNECTOR
INTERNAL POWER
*For dual redundant communication.
1
6
3
4
Pi 1
COM1(–)
Pi 2
COM2(–)
INTERNAL BUS A
INTERNAL BUS B*
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL
Applicable wire size: 0.2 to 2.5 mm2
Stripped length: 7 mm
COUNTER RESET
1) Remove Network Module or its cables and interrupt com-
munication with other devices.
2) Turn ON the Counter Reset SW (SW8) on R5-PA2 mod-
ule.
3) Return the module to the base and turn the power supply
on.
4) Red RUN LED turns on and the module starts resetting
its counter. When the resetting is complete, the LED
turns to green. DO NOT remove the power while the red
LED is on.
5) After the green LED is confirmed, turn the power supply
off.
6) Turn OFF the Counter Reset SW (SW8).
7) Return the Network module onto the base and turn the
power supply on.
Note: Counter Reset SW must be turned OFF after this pro-
cedure because the module does not start counting with
ON state.
R5-PA2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-6139 Rev.2 P. 3 / 3

Other M-system Control Unit manuals

M-system R7M-DC16B User manual

M-system

M-system R7M-DC16B User manual

M-system R3Y-DS8N User manual

M-system

M-system R3Y-DS8N User manual

M-system R6N-RS2 User manual

M-system

M-system R6N-RS2 User manual

M-system F2DL User manual

M-system

M-system F2DL User manual

M-system R7M-EA8 User manual

M-system

M-system R7M-EA8 User manual

M-system R3-PD16A User manual

M-system

M-system R3-PD16A User manual

M-system R7M-DC16A User manual

M-system

M-system R7M-DC16A User manual

M-system R3S-DC8 User manual

M-system

M-system R3S-DC8 User manual

M-system R6S-TS2 User manual

M-system

M-system R6S-TS2 User manual

M-system Devicenet R7F4HD-DAC32C User manual

M-system

M-system Devicenet R7F4HD-DAC32C User manual

M-system R7D-YS2 User manual

M-system

M-system R7D-YS2 User manual

M-system R3-GD1 User manual

M-system

M-system R3-GD1 User manual

M-system R7M-YS2 User manual

M-system

M-system R7M-YS2 User manual

M-system R30YV4 User manual

M-system

M-system R30YV4 User manual

M-system R3-PA2 User manual

M-system

M-system R3-PA2 User manual

M-system TR3EX User manual

M-system

M-system TR3EX User manual

M-system R7C-YS2 User manual

M-system

M-system R7C-YS2 User manual

M-system R7F4HML3-D-DAC32B User manual

M-system

M-system R7F4HML3-D-DAC32B User manual

M-system R3-RR8 User manual

M-system

M-system R3-RR8 User manual

M-system R7C-EC8B/UL User manual

M-system

M-system R7C-EC8B/UL User manual

M-system R7F4DD-DC16A-H User manual

M-system

M-system R7F4DD-DC16A-H User manual

M-system R3-SV8B User manual

M-system

M-system R3-SV8B User manual

M-system R3-AS4 User manual

M-system

M-system R3-AS4 User manual

M-system R7ML-EC16B User manual

M-system

M-system R7ML-EC16B User manual

Popular Control Unit manuals by other brands

Emerson Sempell PSRV VS99 manual

Emerson

Emerson Sempell PSRV VS99 manual

Rockwell Automation Allen-Bradley 1756-EWEB installation instructions

Rockwell Automation

Rockwell Automation Allen-Bradley 1756-EWEB installation instructions

Belimo L Series instruction manual

Belimo

Belimo L Series instruction manual

ABB Relion 615 series Operation manual

ABB

ABB Relion 615 series Operation manual

Cavotec STD-302N-R user manual

Cavotec

Cavotec STD-302N-R user manual

IFM Electronic AL2230 operating instructions

IFM Electronic

IFM Electronic AL2230 operating instructions

Burkert 2103 Series quick start

Burkert

Burkert 2103 Series quick start

BD Alaris PCA Pocket guide

BD

BD Alaris PCA Pocket guide

White Rodgers 36C03 installation instructions

White Rodgers

White Rodgers 36C03 installation instructions

IFM AL1120 operating instructions

IFM

IFM AL1120 operating instructions

National Instruments NI 9853 Getting started guide

National Instruments

National Instruments NI 9853 Getting started guide

hager TYA606A manual

hager

hager TYA606A manual

Dwyer Instruments DP3 Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments DP3 Series Installation and operating instructions

Hawle HAWIDO 1795 manual

Hawle

Hawle HAWIDO 1795 manual

Kitz F14A Operation, maintenance, and installation instructions

Kitz

Kitz F14A Operation, maintenance, and installation instructions

Metso Jamesbury 5000 series Installation, maintenance and operation instructions

Metso

Metso Jamesbury 5000 series Installation, maintenance and operation instructions

Gemini 972AR Installation and use manual

Gemini

Gemini 972AR Installation and use manual

Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF manual

Siemens

Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.