manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R7ML-EC8D User manual

M-system R7ML-EC8D User manual

R7ML-EC8D
P. 1 / 2EM-7805-Y Rev.1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax:
+81(6)6659-8510 E-mail: info@m-system.co.jp
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 8 points
(MECHATROLINK-I/ -II, short circuit protection) MODEL
R7ML-EC8D
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Discrete output extension module................................ (1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVE
•The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
•Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 10mA
■GENERAL PRECAUTIONS
•Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
01234567
Discrete Output Status Indicator LED
Output Terminals
786910
23145
■DISCRETE OUTPUT STATUS INDICATOR LED
Discrete output extension modules have LED indicators
showing output signal status.
Contact ON : LED ON
Contact OFF : LED OFF
■OUTPUT TERMINAL ASSIGNMENT
6
+24V
7
Y1
8
Y3
1
0V
2
Y0
3
Y2
9
Y5
4
Y4
10
Y7
5
Y6
NO. ID FUNCTION NO. ID FUNTION
1 0V 0V 6 +24V 24V DC (common)
2 Y0 Output 0 7 Y1 Output 1
3 Y2 Output 2 8 Y3 Output 3
4 Y4 Output 4 9 Y5 Output 5
5 Y6 Output 6 10 Y7 Output 7
CONNECTING THE EXTENSION MODULE
1) Remove the extension connector cover located at the side
of the basic module.
2) Connect the extension module.
3) Mount the combined module on a DIN rail.
R7ML-EC8D
P. 2 / 2EM-7805-Y Rev.1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax:
+81(6)6659-8510 E-mail: info@m-system.co.jp
EXTERNAL DIMENSIONS unit: mm (inch)
11.5
(.45)
786910
23145
65 (2.56)
30 (1.18) [5 (.20)]
3 (.12)5.5 (.22)
DIN RAIL
35mm wide
54 (2.13)
17 (.66)
50 (1.97) 18.5 (.73)
10–M3 SCREW
TERMINALS
for OUTPUT
6 (.24)
CONNECTION DIAGRAM
Connect the unit as in the diagram below.
EXTENSION CONNECTOR
6
10V
10
Y7
9Y5
8Y3
7Y1
5Y6
4Y4
3Y2
+24V
Y0
2
■ Output Connection Example
6
1
2
Y0
0V
+24V –
+
10
Y7
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminal:
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd, Nichifu Co., Ltd
6 (.24) max
3.3 (.13) max
mm (inch)
I/O DATA DESCRIPTION
015
0:OFF 1:ON
Output 0
Output 1
Output 2
Output 3
Unused
Output 7
Unused
■DISCRETE OUTPUT

Other M-system Control Unit manuals

M-system M8YC User manual

M-system

M-system M8YC User manual

M-system R6S-TS2 User manual

M-system

M-system R6S-TS2 User manual

M-system R7D-MS4 User manual

M-system

M-system R7D-MS4 User manual

M-system M6NPS1 User manual

M-system

M-system M6NPS1 User manual

M-system R7L-RR8 User manual

M-system

M-system R7L-RR8 User manual

M-system R3-PA2 User manual

M-system

M-system R3-PA2 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7M-EC16B User manual

M-system

M-system R7M-EC16B User manual

M-system Mini-M M2ADS User manual

M-system

M-system Mini-M M2ADS User manual

M-system R3-NM3 User manual

M-system

M-system R3-NM3 User manual

M-system Devicenet R7F4HD-DAC32C User manual

M-system

M-system Devicenet R7F4HD-DAC32C User manual

M-system M6SXF3 User manual

M-system

M-system M6SXF3 User manual

M-system R7HL-DC8C User manual

M-system

M-system R7HL-DC8C User manual

M-system F2DL User manual

M-system

M-system F2DL User manual

M-system R3-RR8 User manual

M-system

M-system R3-RR8 User manual

M-system R7F4DD-DC16A-H User manual

M-system

M-system R7F4DD-DC16A-H User manual

M-system R3-NF3 User manual

M-system

M-system R3-NF3 User manual

M-system R3-PD16B User manual

M-system

M-system R3-PD16B User manual

M-system R7C-EC8C User manual

M-system

M-system R7C-EC8C User manual

M-system R3Y-SS8 User manual

M-system

M-system R3Y-SS8 User manual

M-system R7L-YV2 User manual

M-system

M-system R7L-YV2 User manual

M-system R7M-EC8A User manual

M-system

M-system R7M-EC8A User manual

M-system R7C-EC8A User manual

M-system

M-system R7C-EC8A User manual

M-system R7HL-DAC16C User manual

M-system

M-system R7HL-DAC16C User manual

Popular Control Unit manuals by other brands

NCR 7358-K705 Kit instructions

NCR

NCR 7358-K705 Kit instructions

Siemens SIMOTION D410 PN manual

Siemens

Siemens SIMOTION D410 PN manual

Samson 41-73 Series Mounting and operating instructions

Samson

Samson 41-73 Series Mounting and operating instructions

Oxylitre POD Series Operating/safety instructions

Oxylitre

Oxylitre POD Series Operating/safety instructions

Keysight Technologies 81940A user guide

Keysight Technologies

Keysight Technologies 81940A user guide

Lovato EXP10 01 user manual

Lovato

Lovato EXP10 01 user manual

CLA-VAL CRL-60 Installation operation & maintenance

CLA-VAL

CLA-VAL CRL-60 Installation operation & maintenance

Control Techniques UD53 user guide

Control Techniques

Control Techniques UD53 user guide

Panasonic CF-BAC04GU operating instructions

Panasonic

Panasonic CF-BAC04GU operating instructions

Burkert 8630 operating instructions

Burkert

Burkert 8630 operating instructions

Control Techniques EMERSON DeviceNet user guide

Control Techniques

Control Techniques EMERSON DeviceNet user guide

Hayward TC Series Installation, operation and maintenance instructions

Hayward

Hayward TC Series Installation, operation and maintenance instructions

Seitz 2A6 Series operating instructions

Seitz

Seitz 2A6 Series operating instructions

First 710 Series Installation instruction

First

First 710 Series Installation instruction

Texas Instruments MCT8316AEVM user guide

Texas Instruments

Texas Instruments MCT8316AEVM user guide

NASSAU ED520 Functional description

NASSAU

NASSAU ED520 Functional description

Tion IRM330 user manual

Tion

Tion IRM330 user manual

National Instruments NI 9436 Getting started guide

National Instruments

National Instruments NI 9436 Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.