manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system M8CD1 User manual

M-system M8CD1 User manual

This manual suits for next models

1

Other M-system Control Unit manuals

M-system Devicenet R7F4HD-DAC32D User manual

M-system

M-system Devicenet R7F4HD-DAC32D User manual

M-system R7M-YS2 User manual

M-system

M-system R7M-YS2 User manual

M-system R1M-A1 User manual

M-system

M-system R1M-A1 User manual

M-system R7M-DA16 User manual

M-system

M-system R7M-DA16 User manual

M-system R7F4HML3-D-DAC32A User manual

M-system

M-system R7F4HML3-D-DAC32A User manual

M-system R3-SV4B User manual

M-system

M-system R3-SV4B User manual

M-system R7HL-DC16B User manual

M-system

M-system R7HL-DC16B User manual

M-system R7HL-TS4 User manual

M-system

M-system R7HL-TS4 User manual

M-system R3-SV8B User manual

M-system

M-system R3-SV8B User manual

M-system R3-NL1 User manual

M-system

M-system R3-NL1 User manual

M-system R7M-DC16B User manual

M-system

M-system R7M-DC16B User manual

M-system R3-GM1 User manual

M-system

M-system R3-GM1 User manual

M-system R7ML-YV2 User manual

M-system

M-system R7ML-YV2 User manual

M-system R30YV4 User manual

M-system

M-system R30YV4 User manual

M-system R7C-YS2 User manual

M-system

M-system R7C-YS2 User manual

M-system R3-NC2 User manual

M-system

M-system R3-NC2 User manual

M-system 61A User manual

M-system

M-system 61A User manual

M-system R3-PS3 User manual

M-system

M-system R3-PS3 User manual

M-system R7ML-DC16A User manual

M-system

M-system R7ML-DC16A User manual

M-system R7HL-DC8C User manual

M-system

M-system R7HL-DC8C User manual

M-system R7C-EC16A User manual

M-system

M-system R7C-EC16A User manual

M-system R7L-EC16B User manual

M-system

M-system R7L-EC16B User manual

M-system R3-GC1 User manual

M-system

M-system R3-GC1 User manual

M-system R7C-TS4 User manual

M-system

M-system R7C-TS4 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M8CD / M8CD1
EM-5489 Rev.2P. 1 / 2
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner ....................................................... (1)
■ MODEL NO.
Check that model No. described on specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
■ M8CD1: CONFORMITY WITH EC DIRECTIVES
• Functional insulation is maintained between signal input
and output.
• The equipment must be mounted inside a panel.
• Install lightning surge protectors for those wires connected
to remote locations.
• Insert a noise filter for the power source, input and output
connected to the unit. COSEL Noise Filter Model NAC-06-
472, TDK Noise Filter Model ZCAT 3035-1330 or equivalent
is recommended.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may affect
the protection level of this unit when it is integrated in a
panel system. The user may have to review the CE require-
ments in regard to the whole system and employ additional
protective measures to ensure the CE conformity.
■ ENVIRONMENT
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing and ventilate it.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in order
to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with
cables, etc.
■ WIRING
• Do not install cables (input and output) close to noise
sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
INSTRUCTION MANUAL
MODEL
DELAY BUFFER
M8CD
M8CD1
Time Constant Adj.
Specification
Label
Span Adj.
Zero Adj.
Mounting Screw
Body
■ AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■BOTTOM VIEW
• Time Constant Adjustment
Turning the potentiometer clockwise (MAX) increases the
time constant, counterclockwise (MIN) to decrease.
INSTALLATION
Use Installation Base (model: M8BS❑).
MAX
MIN
Time Constant Adj.
M8CD / M8CD1
EM-5489 Rev.2P. 2 / 2
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any calibra-
tion.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■ HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
(Output 1 and Output 2 are linked.)
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure
1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the "ADJUST-
MENT PROCEDURE" explained earlier.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]
+
–
Installation Base
OUTPUT 1
6
7
8
9
10
11
+
–
+
–
OUTPUT 2
1
2
A
B
POWER
+
–
INPUT
I/O PINS
17.5(.69)
48 (1.89)
75 (2.95)
83 (3.27)
TERMINAL CONNECTIONS
Connect the unit as in the diagrams below.
■EXTERNAL DIMENSIONS mm (inch)
■CONNECTION DIAGRAM
CHECKING
1) Terminal wiring: Check that all cables are correctly
connected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.