manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system 10MS User manual

M-system 10MS User manual

10MS / 10MK
P. 1 / 2 EM-0816 Rev.2
INSTRUCTION MANUAL
MODEL
10MS/10MK
POTENTIOMETERTRANSMITTER
COMPONENT IDENTIFICATION
INSTALLATION
Use Standard Rack (model: 10BX❑).
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the
connection diagram label on the unit side.
CHECKING
1) Terminal wiring: Check that all cables are correctly
connected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 10BX❑). For the DC power source, be sure that
the ripple level is within 10% p-p.
3) Input: Check voltage across the terminal 2 (+) – 3 (–) with
a voltmeter to show 0V at 0% potentiometer input and the
same voltage as that across 1 (+) –␣ 3 (–) at 100% input.
4) Output: Check that the load resistance meets the de-
scribed specifications.
Zero Adj.
Span Adj. Output 1
Body
Specification Label
Connection Diagram
Label
(side)
Zero Adj.
Output 2*Span Adj.
Terminal Cover
*Provided only when the second output is selected.
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner ................................................... (1)
■ MODEL NO.
Check that model No. described on specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
■ POWER INPUT RATINGS
• Power input ratings are specified by the model number
suffix code. Check the power input voltage for the unit on the
specification label.
24V DC ±10%, approx. 35mA with Voltage Output 1
approx. 55mA with Current Output 1
■ GENERAL
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing and ventilate it.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -5 to +55°C (23
to131°F)withrelativehumiditywithin30to90%RHinorder
to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
+
–
+
–
1
OUTPUT 1
7
8
+
–
OUTPUT 2
5
6
CONNECTOR
*1 output type has the output 1 connected to the
card-edge connector in parallel.
OUTPUT 2*
POWER
2
3
2
1
POTENTIOMETER
max.
min.
3
10MS / 10MK
P. 2 / 2 EM-0816 Rev.2
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory with the total resistance
input, therefore you do not need any calibration if you use the
potentiometer's total resistance.
When you don't use the total resistance or in case of regular
calibration, adjust the output as explained in the following.
■ HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure
1) – 3).
5) Go through the same procedure for Output 2. Extender
Card (model: 10EC) is required to access the Output 2
Adjustments on top of the unit maintaining electrical
connection at the rear connector.
EXTERNAL DIMENSIONS mm (inch)
130 (5.12)
3 (.12)
50 (1.97)
82 (3.23)
2–4.3 (.17) dia.
MTG HOLE TERMINAL COVER
7–M3.5 SCREW
8 (.31)
91 (3.58)
99 (3.90 )
25 (.98)
12
3
56
78
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the "ADJUST-
MENT PROCEDURE" explained earlier.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

This manual suits for next models

1

Other M-system Transmitter manuals

M-system 6M User manual

M-system

M-system 6M User manual

M-system 10SP User manual

M-system

M-system 10SP User manual

M-system W2CFG User manual

M-system

M-system W2CFG User manual

M-system F2TS User manual

M-system

M-system F2TS User manual

M-system JR User manual

M-system

M-system JR User manual

M-system W5MS User manual

M-system

M-system W5MS User manual

M-system JPA2 User manual

M-system

M-system JPA2 User manual

M-system MXS User manual

M-system

M-system MXS User manual

M-system M3LT User manual

M-system

M-system M3LT User manual

M-system M5MS-5-R User manual

M-system

M-system M5MS-5-R User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

M-system M5VF User manual

M-system

M-system M5VF User manual

M-system VOS2T User manual

M-system

M-system VOS2T User manual

M-system Mini-M M2PA User manual

M-system

M-system Mini-M M2PA User manual

M-system M5XREB User manual

M-system

M-system M5XREB User manual

M-system WRS2 User manual

M-system

M-system WRS2 User manual

M-system 99SVA User manual

M-system

M-system 99SVA User manual

M-system 18KJV User manual

M-system

M-system 18KJV User manual

M-system Mini-M M2RS User manual

M-system

M-system Mini-M M2RS User manual

M-system W2TS User manual

M-system

M-system W2TS User manual

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system KWVS2 User manual

M-system

M-system KWVS2 User manual

M-system M2EXS User manual

M-system

M-system M2EXS User manual

M-system 6PA User manual

M-system

M-system 6PA User manual

Popular Transmitter manuals by other brands

Panametrics DigitalFlow XMT868i Programming manual

Panametrics

Panametrics DigitalFlow XMT868i Programming manual

INVISIBLE FENCE ICT 700 owner's manual

INVISIBLE FENCE

INVISIBLE FENCE ICT 700 owner's manual

Lectrosonics DBu instruction manual

Lectrosonics

Lectrosonics DBu instruction manual

Danfoss AKS 41 Technical leaflet

Danfoss

Danfoss AKS 41 Technical leaflet

RKI Instruments 65-2396RK 04 Series Operator's manual

RKI Instruments

RKI Instruments 65-2396RK 04 Series Operator's manual

elero TempoTel 28 260.0001 operating instructions

elero

elero TempoTel 28 260.0001 operating instructions

Endress+Hauser Liquiline M OM42 technical information

Endress+Hauser

Endress+Hauser Liquiline M OM42 technical information

Endress+Hauser Cerabar S PMC71 technical information

Endress+Hauser

Endress+Hauser Cerabar S PMC71 technical information

GEORGIN ProcessX Series instruction manual

GEORGIN

GEORGIN ProcessX Series instruction manual

PR PRetrans 6333 manual

PR

PR PRetrans 6333 manual

Endress+Hauser AT1000 AT1 operating instructions

Endress+Hauser

Endress+Hauser AT1000 AT1 operating instructions

elero UniTec-868 operating instructions

elero

elero UniTec-868 operating instructions

Siemens SITRANS L Series operating instructions

Siemens

Siemens SITRANS L Series operating instructions

Axcera CHV400BTD Technical manual

Axcera

Axcera CHV400BTD Technical manual

Sennheiser SK 300 instruction manual

Sennheiser

Sennheiser SK 300 instruction manual

Speaka Professional 2226164 operating instructions

Speaka Professional

Speaka Professional 2226164 operating instructions

JUMO DELOS SI operating manual

JUMO

JUMO DELOS SI operating manual

CSS AssistX IR one quick guide

CSS

CSS AssistX IR one quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.