COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT PANEL CONFIGURATION (with the cover open)
Span Adj.
Zero Adj.
5
87
6
12
43
INSTALLATION
Use Standard Rack (model: 17BXE).
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner ....................................................(1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
24 V DC ±10%, approx. 35 mA
■ REMOVING THE UNIT
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 40 to 85% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
PT TRANSMITTER MODEL 17PE
INSTRUCTION MANUAL
17PE
P. 2 / 2EM-2938
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: inf[email protected].jp
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■ DIMENSIONS mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■ CONNECTION DIAGRAM
1
2
LOAD
SOURCE
V
U
v
u
FUSE
FUSE
VT
OUTPUT
AUXILIARY
POWER
CONNECTOR
■ TERMINAL ASSIGNMENTS
12
34
78
56
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Auxiliary power supply voltage: Check voltage supplied to
the rack (model: 17BXE). Use a power source of ripple
level 10% p-p or less.
3) Input: Check that the input voltage is within 0 – 120%
of the rated voltage.
4) Output: Check that the load resistance meets the described
specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered speci-
fications, therefore you usually do not need any calibration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■ HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the auxiliary power supply on and warm
up for more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above procedure
1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accuracy
described in the data sheet. When the output is out of toler-
ance, recalibrate the unit according to the "ADJUSTMENT
PROCEDURE" explained earlier.
LIGHTNING SURGE PROTECTION
In order to protect the unit from lightning surges entering
through signal and power supply cables, use of appropriate
lightning surge protectors are recommended. Please contact
M-System.

Other M-system Transmitter manuals

M-system M80YS User manual

M-system

M-system M80YS User manual

M-system Mini-M M2UDS2 User manual

M-system

M-system Mini-M M2UDS2 User manual

M-system M2EXV User manual

M-system

M-system M2EXV User manual

M-system Mini-M M2REB User manual

M-system

M-system Mini-M M2REB User manual

M-system Mini-M M2XRP2 User manual

M-system

M-system Mini-M M2XRP2 User manual

M-system M2LPM User manual

M-system

M-system M2LPM User manual

M-system F2TS User manual

M-system

M-system F2TS User manual

M-system M6SCTC User manual

M-system

M-system M6SCTC User manual

M-system M3LU2 User manual

M-system

M-system M3LU2 User manual

M-system Mini-M M2XU User manual

M-system

M-system Mini-M M2XU User manual

M-system M3LU User manual

M-system

M-system M3LU User manual

M-system M1EXM-2 User manual

M-system

M-system M1EXM-2 User manual

M-system W2MS User manual

M-system

M-system W2MS User manual

M-system W2TS User manual

M-system

M-system W2TS User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system TM User manual

M-system

M-system TM User manual

M-system 6BPA User manual

M-system

M-system 6BPA User manual

M-system 10VF2 User manual

M-system

M-system 10VF2 User manual

M-system W2VS User manual

M-system

M-system W2VS User manual

M-system W5RS User manual

M-system

M-system W5RS User manual

M-system Mini-M M2SP User manual

M-system

M-system Mini-M M2SP User manual

M-system F2VF User manual

M-system

M-system F2VF User manual

M-system Mini-M M2DY User manual

M-system

M-system Mini-M M2DY User manual

M-system Mini-M M2E Series User manual

M-system

M-system Mini-M M2E Series User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.