manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system KCEC User manual

M-system KCEC User manual

Other M-system Transmitter manuals

M-system Mini-M M2DU User manual

M-system

M-system Mini-M M2DU User manual

M-system Mini-M M2TS User manual

M-system

M-system Mini-M M2TS User manual

M-system 35mm User manual

M-system

M-system 35mm User manual

M-system Mini-M M2XRP2 User manual

M-system

M-system Mini-M M2XRP2 User manual

M-system SENTRONIC M2SES User manual

M-system

M-system SENTRONIC M2SES User manual

M-system W2XR User manual

M-system

M-system W2XR User manual

M-system M5 Series User manual

M-system

M-system M5 Series User manual

M-system M2VF User manual

M-system

M-system M2VF User manual

M-system B3HU User manual

M-system

M-system B3HU User manual

M-system W2VABS User manual

M-system

M-system W2VABS User manual

M-system 27RS User manual

M-system

M-system 27RS User manual

M-system Mini-M M2AC User manual

M-system

M-system Mini-M M2AC User manual

M-system W2MS User manual

M-system

M-system W2MS User manual

M-system W2PA User manual

M-system

M-system W2PA User manual

M-system 10TS User manual

M-system

M-system 10TS User manual

M-system Mini-MW Series User manual

M-system

M-system Mini-MW Series User manual

M-system W2VF User manual

M-system

M-system W2VF User manual

M-system M80YS User manual

M-system

M-system M80YS User manual

M-system Mini-M M2YV User manual

M-system

M-system Mini-M M2YV User manual

M-system B3FR User manual

M-system

M-system B3FR User manual

M-system F2TS User manual

M-system

M-system F2TS User manual

M-system M3LPA2 User manual

M-system

M-system M3LPA2 User manual

M-system M3LR User manual

M-system

M-system M3LR User manual

M-system M2EXV User manual

M-system

M-system M2EXV User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
Sensor ..................................................................................(1)
Cable (CLSA-08, -12 only) ..................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■AUXILIARY POWER INPUT RATING & OPERATIONAL RANGE
• Locate the auxiliary power input rating marked on the
product and confirm its operational range as indicated
below:
AC power: Rating -15/+10%, 50/60 Hz, approx. 3VA
DC power: Rating ±10%, approx. 2W
or 85 – 150V, approx. 2W for 110V rating
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside a proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 85% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
K
-UNIT
Body Base Socket
Specifications
Zero Adj.
Span Adj.
INSTALLATION
Detach the yellow clamps located at the top and bottom of
the unit for separate the body from the base socket.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
■DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Hang the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN
rail adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
■CLAMP-ON CURRENT SENSOR
Secure the sensor to the cable e.g. using tie wraps.
Over-voltage clamp element is incorporated for safety in
open circuit.
CT TRANSMITTER
(clamp-on current sensor) MODEL KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 1 / 4
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
3456
2187
80 (3.15)
50 (1.97) 103 (4.06)
123 (4.84) [3.3 (.13)]
80 (3.15)
20
(.79)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2
–
4.5 (.18) dia.
MTG HOLE
15 (.59) deep
8
–
M3.5
SCREW
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
LOAD
SOURCE
l
k
L
K
+
–
OUTPUT
1
2
3
4
CONNECTOR*
CLAMP-ON SENSOR
*Connector provided only for the CLSA-08 and CLSA-12.
U(+)
V(–)
AUXILIARY POWER
7
8
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Auxiliary power input voltage: Check voltage across the
terminal 7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of suffi-
cient accuracy level. Turn the auxiliary power supply on
and warm up for more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 2 / 4
CLAMP-ON CURRENT SENSOR
The clamp-on current sensor is included in the product package.
■CLAMP-ON CURRENT SENSOR (leadwire type CLSA)
• 0 – 10A through 0 – 75A Use
Sensor model No.: CLSA-08
Sensor cable model No.: CLSA-08C-30
Applicable cable diameter: Max. 10.0
Sensor leadwire: AWG 22
Weight: 45 g (1.6 oz)
LK
10 (.39)
dia.
41 (1.61)
23 (.91)
27 (1.05)26 (1.02)
150 (5.91) 3000 (118)
l
k
• 0 – 100A Use
Sensor model No.: CLSA-12
Sensor cable model No.: CLSA-08C-30
Applicable cable diameter: Max. 16.0
Sensor leadwire: AWG 22
Weight: 70 g (2.5 oz)
16 (.63)
dia.
44.5 (1.75)
29 (1.14)
30 (1.18)
31 (1.22)
150 (5.91)
l
k
LK
3000 (118)
• 0 – 125A through 0 – 300A Use
Sensor model No.: CLSA-30
Applicable cable diameter: Max. 24.0
Sensor leadwire: AWG 18, 200 mm
Weight: 200 g (7.1 oz)
24 (.94)
dia.
64 (2.52)
47.5 (1.87)
40 (1.57)34 (1.34)
200 (7.87)
4
(.16)
4
(.16)
l
k
KL
• 0 – 350A through 0 – 500A Use
Sensor model No.: CLSA-50
Applicable cable diameter: Max. 36.0
Sensor leadwire: AWG 18, 200 mm
Weight: 300 g (10.6 oz)
36 (1.41)
dia.
80 (3.15)
59.5 (2.34)
50 (1.97)38 (1.50) 4
(.16)
4
(.16)
200 (7.87)
l
k
KL
■CLAMP-ON CURRENT SENSOR (screw terminal type CLSB)
Connection: M3 screw terminal (torque 0.5 N·m)
Screw terminal: Nickel-plated steel
Output wiring: Use AWG 22 or thicker wires for the output.
Twist the paired wires, extendable up to 30 meters.
• 0 – 10A through 0 – 50A Use
Sensor model No.: CLSB-05
Applicable cable diameter: Max. 10.0
Weight: 45 g (1.6 oz)
k
k
l
l
28.9 (1.14)
26.3 (1.04)8.6
(.34)
8.6
(.34)
48 (1.89)
10 dia. (.39)
2–M3 SCREW
TERMINAL COVER
(detachable)
KL
• 0 – 60A through 0 – 100A Use
Sensor model No.: CLSB-10
Applicable cable diameter: Max. 16.0
Weight: 80 g (2.8 oz)
37.4 (1.47)
30.5 (1.20)7.5
(.30)
7.5
(.30)
53.7 (2.11)
16 dia. (.63)
2–M3 SCREW
k
k
l
l
TERMINAL COVER
(detachable)
KL
• 0 – 125A through 0 – 200A Use
Sensor model No.: CLSB-20
Applicable cable diameter: Max. 24.0
Weight: 200 g (7.1 oz)
k
k
l
l
2–M3 SCREW
55.9 (2.20)
35.9
(1.41)
8.3
(.33)
8.3
(.33)
75.7 (2.98)
24 dia. (.94)
TERMINAL COVER
(detachable)
KL
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 3 / 4
• 0 – 225A through 0 – 400A Use
Sensor model No.: CLSB-40
Applicable cable diameter: Max. 35.0
Weight: 300 g (10.6 oz)
35 dia. (1.38)
k
k
l
l
2–M3 SCREW
KL
73.5 (2.89)
35.5
(1.40)
8.8
(.35)
8.8
(.35)
93 (3.66)
TERMINAL COVER
(detachable)
• 0 – 500A through 0 – 600A Use
Sensor model No.: CLSB-60
Applicable cable diameter: Max. 35.0
Weight: 360 g (12.7 oz)
73.5 (2.89)
35.5
(1.40)
8.8
(.35)
8.8
(.35)
93 (3.66)
TERMINAL COVER
(detachable)
35 dia. (1.38)
k
k
l
l
2–M3 SCREW
KL
Note 1: The output values may vary depending on the accuracy
of engagement at the clamp connection.
Note 2: The sensor is detachable up to 100 times (approx.).
Note 3: The sensor’s mechanical construction may cause it to
generate resonance sound. However, it does not affect
the performance of the sensor.
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 4 / 4