manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Transmitter
  8. •
  9. M-system KCEC User manual

M-system KCEC User manual

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
Sensor ..................................................................................(1)
Cable (CLSA-08, -12 only) ..................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■AUXILIARY POWER INPUT RATING & OPERATIONAL RANGE
• Locate the auxiliary power input rating marked on the
product and confirm its operational range as indicated
below:
AC power: Rating -15/+10%, 50/60 Hz, approx. 3VA
DC power: Rating ±10%, approx. 2W
or 85 – 150V, approx. 2W for 110V rating
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside a proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 85% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
K
-UNIT
Body Base Socket
Specifications
Zero Adj.
Span Adj.
INSTALLATION
Detach the yellow clamps located at the top and bottom of
the unit for separate the body from the base socket.
Clamp
(top & bottom)
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
Shape and size of the base socket
are slightly different with various
socket types.
■DIN RAIL MOUNTING
Set the base socket so that its
DIN rail adaptor is at the bot-
tom. Hang the upper hook at
the rear side of base socket on
the DIN rail and push in the
lower. When removing the
socket, push down the DIN
rail adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DI-
MENSIONS.”
■CLAMP-ON CURRENT SENSOR
Secure the sensor to the cable e.g. using tie wraps.
Over-voltage clamp element is incorporated for safety in
open circuit.
CT TRANSMITTER
(clamp-on current sensor) MODEL KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 1 / 4
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the front of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
3456
2187
80 (3.15)
50 (1.97) 103 (4.06)
123 (4.84) [3.3 (.13)]
80 (3.15)
20
(.79)
40 (1.57)
50 (1.97)
7.8 (.31)
CLAMP
(top & bottom)
DIN RAIL
35mm wide
2
–
4.5 (.18) dia.
MTG HOLE
15 (.59) deep
8
–
M3.5
SCREW
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
LOAD
SOURCE
l
k
L
K
+
–
OUTPUT
1
2
3
4
CONNECTOR*
CLAMP-ON SENSOR
*Connector provided only for the CLSA-08 and CLSA-12.
U(+)
V(–)
AUXILIARY POWER
7
8
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Auxiliary power input voltage: Check voltage across the
terminal 7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of suffi-
cient accuracy level. Turn the auxiliary power supply on
and warm up for more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 2 / 4
CLAMP-ON CURRENT SENSOR
The clamp-on current sensor is included in the product package.
■CLAMP-ON CURRENT SENSOR (leadwire type CLSA)
• 0 – 10A through 0 – 75A Use
Sensor model No.: CLSA-08
Sensor cable model No.: CLSA-08C-30
Applicable cable diameter: Max. 10.0
Sensor leadwire: AWG 22
Weight: 45 g (1.6 oz)
LK
10 (.39)
dia.
41 (1.61)
23 (.91)
27 (1.05)26 (1.02)
150 (5.91) 3000 (118)
l
k
• 0 – 100A Use
Sensor model No.: CLSA-12
Sensor cable model No.: CLSA-08C-30
Applicable cable diameter: Max. 16.0
Sensor leadwire: AWG 22
Weight: 70 g (2.5 oz)
16 (.63)
dia.
44.5 (1.75)
29 (1.14)
30 (1.18)
31 (1.22)
150 (5.91)
l
k
LK
3000 (118)
• 0 – 125A through 0 – 300A Use
Sensor model No.: CLSA-30
Applicable cable diameter: Max. 24.0
Sensor leadwire: AWG 18, 200 mm
Weight: 200 g (7.1 oz)
24 (.94)
dia.
64 (2.52)
47.5 (1.87)
40 (1.57)34 (1.34)
200 (7.87)
4
(.16)
4
(.16)
l
k
KL
• 0 – 350A through 0 – 500A Use
Sensor model No.: CLSA-50
Applicable cable diameter: Max. 36.0
Sensor leadwire: AWG 18, 200 mm
Weight: 300 g (10.6 oz)
36 (1.41)
dia.
80 (3.15)
59.5 (2.34)
50 (1.97)38 (1.50) 4
(.16)
4
(.16)
200 (7.87)
l
k
KL
■CLAMP-ON CURRENT SENSOR (screw terminal type CLSB)
Connection: M3 screw terminal (torque 0.5 N·m)
Screw terminal: Nickel-plated steel
Output wiring: Use AWG 22 or thicker wires for the output.
Twist the paired wires, extendable up to 30 meters.
• 0 – 10A through 0 – 50A Use
Sensor model No.: CLSB-05
Applicable cable diameter: Max. 10.0
Weight: 45 g (1.6 oz)
k
k
l
l
28.9 (1.14)
26.3 (1.04)8.6
(.34)
8.6
(.34)
48 (1.89)
10 dia. (.39)
2–M3 SCREW
TERMINAL COVER
(detachable)
KL
• 0 – 60A through 0 – 100A Use
Sensor model No.: CLSB-10
Applicable cable diameter: Max. 16.0
Weight: 80 g (2.8 oz)
37.4 (1.47)
30.5 (1.20)7.5
(.30)
7.5
(.30)
53.7 (2.11)
16 dia. (.63)
2–M3 SCREW
k
k
l
l
TERMINAL COVER
(detachable)
KL
• 0 – 125A through 0 – 200A Use
Sensor model No.: CLSB-20
Applicable cable diameter: Max. 24.0
Weight: 200 g (7.1 oz)
k
k
l
l
2–M3 SCREW
55.9 (2.20)
35.9
(1.41)
8.3
(.33)
8.3
(.33)
75.7 (2.98)
24 dia. (.94)
TERMINAL COVER
(detachable)
KL
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 3 / 4
• 0 – 225A through 0 – 400A Use
Sensor model No.: CLSB-40
Applicable cable diameter: Max. 35.0
Weight: 300 g (10.6 oz)
35 dia. (1.38)
k
k
l
l
2–M3 SCREW
KL
73.5 (2.89)
35.5
(1.40)
8.8
(.35)
8.8
(.35)
93 (3.66)
TERMINAL COVER
(detachable)
• 0 – 500A through 0 – 600A Use
Sensor model No.: CLSB-60
Applicable cable diameter: Max. 35.0
Weight: 360 g (12.7 oz)
73.5 (2.89)
35.5
(1.40)
8.8
(.35)
8.8
(.35)
93 (3.66)
TERMINAL COVER
(detachable)
35 dia. (1.38)
k
k
l
l
2–M3 SCREW
KL
Note 1: The output values may vary depending on the accuracy
of engagement at the clamp connection.
Note 2: The sensor is detachable up to 100 times (approx.).
Note 3: The sensor’s mechanical construction may cause it to
generate resonance sound. However, it does not affect
the performance of the sensor.
KCEC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-3560 Rev.3 P. 4 / 4

Other M-system Transmitter manuals

M-system M5XU User manual

M-system

M-system M5XU User manual

M-system VOS2T User manual

M-system

M-system VOS2T User manual

M-system 6BPA User manual

M-system

M-system 6BPA User manual

M-system M5CT User manual

M-system

M-system M5CT User manual

M-system M3LT User manual

M-system

M-system M3LT User manual

M-system CT TRANSMITTER User manual

M-system

M-system CT TRANSMITTER User manual

M-system Mini-M Series User manual

M-system

M-system Mini-M Series User manual

M-system 10SP User manual

M-system

M-system 10SP User manual

M-system M2ADS User manual

M-system

M-system M2ADS User manual

M-system Mini-M M2XT2 User manual

M-system

M-system Mini-M M2XT2 User manual

M-system Mini-M M2REB User manual

M-system

M-system Mini-M M2REB User manual

M-system M2EXV User manual

M-system

M-system M2EXV User manual

M-system M6SCTC User manual

M-system

M-system M6SCTC User manual

M-system Mini-M M2RS1 User manual

M-system

M-system Mini-M M2RS1 User manual

M-system M6DXU User manual

M-system

M-system M6DXU User manual

M-system Mini-M M2RTS User manual

M-system

M-system Mini-M M2RTS User manual

M-system 10JPA User manual

M-system

M-system 10JPA User manual

M-system VOS2T-R User manual

M-system

M-system VOS2T-R User manual

M-system Mini-M M2YV User manual

M-system

M-system Mini-M M2YV User manual

M-system M5VS Series User manual

M-system

M-system M5VS Series User manual

M-system M1EXV-1 User manual

M-system

M-system M1EXV-1 User manual

M-system M3LU2 User manual

M-system

M-system M3LU2 User manual

M-system 10JV User manual

M-system

M-system 10JV User manual

M-system M3LU User manual

M-system

M-system M3LU User manual

Popular Transmitter manuals by other brands

Sony TMR-RF915R Servise manual

Sony

Sony TMR-RF915R Servise manual

Comtek M-216 Operator's manual

Comtek

Comtek M-216 Operator's manual

Thor Broadcast F-RF-1550-Tx user manual

Thor Broadcast

Thor Broadcast F-RF-1550-Tx user manual

PST MICHELL Instrucments Easidew PRO I.S. for... user manual

PST

PST MICHELL Instrucments Easidew PRO I.S. for... user manual

Honeywell ADEMCO 5817 Installation and setup guide

Honeywell

Honeywell ADEMCO 5817 Installation and setup guide

Technalogix TXF-1000 operating manual

Technalogix

Technalogix TXF-1000 operating manual

Rice Lake SCT-3300 installation manual

Rice Lake

Rice Lake SCT-3300 installation manual

Infineon WLC1150 user guide

Infineon

Infineon WLC1150 user guide

ARG ARG-TX-900V-BP Manual and user guide

ARG

ARG ARG-TX-900V-BP Manual and user guide

Axcera Innovator LX Series instruction manual

Axcera

Axcera Innovator LX Series instruction manual

Omega EWS-BP-A user guide

Omega

Omega EWS-BP-A user guide

Williams Sound Personal PA T46 user manual

Williams Sound

Williams Sound Personal PA T46 user manual

YOKOGAWA Dpharp vigilantplant EJA510A user manual

YOKOGAWA

YOKOGAWA Dpharp vigilantplant EJA510A user manual

ACS Precont S Technical manual

ACS

ACS Precont S Technical manual

evertz 7707MTA-HD manual

evertz

evertz 7707MTA-HD manual

BWI Eagle AIR-EAGLE FM2 43-1100 Product information bulletin

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1100 Product information bulletin

BWI Eagle AIR-EAGLE XLT Product information bulletin

BWI Eagle

BWI Eagle AIR-EAGLE XLT Product information bulletin

Master VECTOR 24 manual

Master

Master VECTOR 24 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.