EM-5012 Rev.13 P. 1 / 3
INSTRUCTION MANUAL
Mini-M™
THERMOCOUPLE TRANSMITTER MODEL M2TS
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket + CJC sensor)......(1)
Sealing label (option /VN).........................................(1 sheet)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■WARNING
• If equipment is not used in a manner not specified by M-
System, the protection provided by the equipment may
be impaired.
■NONINCENDIVE APPROVAL OPTION
• This equipment is suitable for use in Class I, Div. 2,
Groups A, B, C and D or Non-Hazardous Locations only.
• WARNING! Before You Remove the Unit from Its Base
Socket or Mount It, Turn Off the Power Supply and Input
Signal for Safety.
• WARNING! – Explosion Hazard –
Substitution of Components May Impair Suitability for
Class I, Div. 2.
• WARNING! – Explosion Hazard –
Do Not Disconnect Equipment Unless Power Has Been
Switched Off or The Area is Known To Be Non-Hazardous.
• The equipment was evaluated for use in the ambient tem-
perature and relative humidity as mentioned in ‘ENVI-
RONMENT’ section.
• The input and output wiring must be in accordance with
Class I, Div. 2 wiring methods and in accordance with the
authority having jurisdiction for use in these hazardous
locations.
■CONFORMITY WITH EU DIRECTIVES OR UL
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II (transient voltage 2500V). Rein-
forced insulation (signal input or output to power input:
300V) and basic insulation (signal input to output: 300V)
are maintained. Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.
• The equipment must be mounted inside a suitable fire
enclosure.
• Altitude up to 2000 meters.
• Insert noise filters for the power source, input and output
connected to the unit. COSEL Model NAC-04-472, TDK
Model ZCAT 3035-1330 or equivalent is recommended.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE/UL requirements. Failure to observe these
requirements may invalidate the CE/UL conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V and 85 – 264V AC rating: 85 – 264V
(90 – 264V for UL), 47 – 66 Hz, approx. 3 – 5VA
24V DC rating: 24V ±10%, approx. 3W
11 – 27V DC rating: 11 – 27V, approx. 3W
110V DC rating: 85 – 150V (110V ±10% for UL), approx. 3W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
• With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to
endure it without breakdown, however, it may shorten ap-
propriate life duration.
M2TS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5012 Rev.13 P. 2 / 3
COMPONENT IDENTIFICATION
CJC
Sensor
Model
SPAN
ZERO
Zero Adj.
Span Adj.
Body Base Socket
Connection
Diagram
Specifications
Fixing Screw
INSTALLATION
Loosen the fixing screw at the front of the unit in order to
separate the body from the base socket.
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
■DIN RAIL MOUNTING
Set the base socket so that
its DIN rail adaptor is at
the bottom. Position the
upper hook at the rear side
of base socket on the DIN
rail and push in the lower.
When removing the socket,
push down the DIN rail
adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DIMENSIONS.”
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
Attach the CJC sensor together with input wiring to the input terminals. The CJC sensor is not interchangeable. Check that
its serial number is identical to that of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
5
9
21.5 (.85)
70.5 (2.78)
84 (3.31)10 (.39) 15 (.59)
6 (.23)
59 (2.32)
DIN RAIL
35mm wide
[4 (.16)]
8–M3
SCREW
72 (2.83)
23 (.91)
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
114 (4.49)
• When mounting, no extra space is needed between units.
4
8
12
14 13
1
4 (.16)
■CONNECTION DIAGRAM
1
+
–
T / C
CJC
SENSOR
metal leg
model: CJM
comp. leadwire
5
4
+
–
+
–
OUTPUT
9
12
U(+)
V(–)
POWER
13
14
■TERMINAL ASSIGNMENTS unit: mm (inch)
8
9
12
14 13
CJC SENSOR
(model: CJM)
14 (.55)
1 14
5
M2TS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5012 Rev.13 P. 3 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
13 – 14 with a multimeter.
3) Input: Check that the input voltage is within 0 – 100% of
full-scale.
If the thermocouple or its extension wires are broken, the
output goes over 100% (below 0% with downscale) due to
burnout function. Check leadwires in such a case.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
Note: Remove the sealing label for /VN option.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Transmitter manuals

M-system M6DXU User manual

M-system

M-system M6DXU User manual

M-system M5XV User manual

M-system

M-system M5XV User manual

M-system MXLC User manual

M-system

M-system MXLC User manual

M-system F2VS User manual

M-system

M-system F2VS User manual

M-system 27U User manual

M-system

M-system 27U User manual

M-system MFS2 User manual

M-system

M-system MFS2 User manual

M-system M3SMS User manual

M-system

M-system M3SMS User manual

M-system W2CA User manual

M-system

M-system W2CA User manual

M-system M5CT-5AM User manual

M-system

M-system M5CT-5AM User manual

M-system Mini-M M2REB User manual

M-system

M-system Mini-M M2REB User manual

M-system M3LM User manual

M-system

M-system M3LM User manual

M-system B3FV User manual

M-system

M-system B3FV User manual

M-system KCEC User manual

M-system

M-system KCEC User manual

M-system Mini-M M2XRP2 User manual

M-system

M-system Mini-M M2XRP2 User manual

M-system RB User manual

M-system

M-system RB User manual

M-system 10AC User manual

M-system

M-system 10AC User manual

M-system W2MS User manual

M-system

M-system W2MS User manual

M-system 18KJV User manual

M-system

M-system 18KJV User manual

M-system F2VF User manual

M-system

M-system F2VF User manual

M-system W2RS1 User manual

M-system

M-system W2RS1 User manual

M-system 10VS User manual

M-system

M-system 10VS User manual

M-system Mini-M M2EXT User manual

M-system

M-system Mini-M M2EXT User manual

M-system M5PT User manual

M-system

M-system M5PT User manual

M-system Mini-M M2SP User manual

M-system

M-system Mini-M M2SP User manual

Popular Transmitter manuals by other brands

Status SEM320/55 user guide

Status

Status SEM320/55 user guide

ABB TB82PH operating instructions

ABB

ABB TB82PH operating instructions

Magnetrol Jupiter JM4 operating manual

Magnetrol

Magnetrol Jupiter JM4 operating manual

Elecsky RF-FM-5C manual

Elecsky

Elecsky RF-FM-5C manual

NET-K WT-1550-EM30 operating manual

NET-K

NET-K WT-1550-EM30 operating manual

SICK PBT operating instructions

SICK

SICK PBT operating instructions

Star Meter KPE 9039G installation instructions

Star Meter

Star Meter KPE 9039G installation instructions

Chiayo SM-7100 IrDA Operation manual

Chiayo

Chiayo SM-7100 IrDA Operation manual

Midland F-12 owner's manual

Midland

Midland F-12 owner's manual

GDD Instrumentation TxIII instruction manual

GDD Instrumentation

GDD Instrumentation TxIII instruction manual

Bellman & Symfon Bellman Visit 868 manual

Bellman & Symfon

Bellman & Symfon Bellman Visit 868 manual

Metal Samples MS2700E Operator's manual

Metal Samples

Metal Samples MS2700E Operator's manual

GRAUPNER mz-10c manual

GRAUPNER

GRAUPNER mz-10c manual

ATEN VE2812AUST user manual

ATEN

ATEN VE2812AUST user manual

SGM LEKTRA TC26 quick start guide

SGM LEKTRA

SGM LEKTRA TC26 quick start guide

Meister MONITOR operating instructions

Meister

Meister MONITOR operating instructions

Xylem MJK pHix Compact V3 manual

Xylem

Xylem MJK pHix Compact V3 manual

HYDACELECTRONIC HLT 2100 Series operating instructions

HYDACELECTRONIC

HYDACELECTRONIC HLT 2100 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.