Product User Guide | 2
PR1000
PRODUCT USER GUIDE
Product Overview
The PR1000 is a pressure and temperature data logger
used to accurately monitor and record pressure and
temperature at user programmable reading intervals.
The rugged stainless steel design allows for the device
to be placed in harsh environments, which makes it well
suited for use with air conditioning systems, chilled water,
hot water, air, gas, oil and steam pressure systems. The
PR1000 also monitors and records transient pressure
through software configuration. Once the user defined
threshold is met, the PR1000 will record at up to 128Hz for
a user defined time period.
Water Resistance
The PR1000 is fully submersible and is rated IP68. It can be
placed in environments with up to 230 ft (70 m) of water.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Connect the device
into a USB port with the interface cable and install the
drivers.
Ordering Information
• 902244-00 — PR1000-1000-PSIA
• 902241-00 — PR1000-100-PSIA
• 902247-00 — PR1000-100-PSIG
• 902242-00 — PR1000-300-PSIA
• 902248-00 — PR1000-300-PSIG
• 902240-00 — PR1000-30-PSIA
• 902246-00 — PR1000-30-PSIG
• 902245-00 — PR1000-5000-PSIA
• 902243-00 — PR1000-500-PSIA
• 902249-00 — PR1000-500-PSIG
• 902274-00 — PR1000-1000-PSIA-KR
• 902271-00 — PR1000-100-PSIA-KR
• 902277-00 — PR1000-100-PSIG-KR
• 902272-00 — PR1000-300-PSIA-KR
• 902278-00 — PR1000-300-PSIG-KR
• 902270-00 — PR1000-30-PSIA-KR
• 902276-00 — PR1000-30-PSIG-KR
• 902275-00 — PR1000-5000-PSIA-KR
• 902273-00 — PR1000-500-PSIA-KR
• 902279-00 — PR1000-500-PSIG-KR
• 900319-00 — IFC400
• 900325-00 — IFC406
• 901745-00 — TL-2150/S Replacement Battery
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.