Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
DOC-1210035-00 REV 7 2014.11.26
Volt101A &
Volt101A-160
Volt101A-2.5V
2.5VDC Voltage Data Logger
Volt101A-15V
15VDC Voltage Data Logger
Volt101A-30V
30VDC Voltage Data Logger
Volt101A-160mV
+160mVDC Differential Voltage
Data Logger
Description Volt101A Volt101A-160mV
Range
*See Table for Details
±160 mVDC
Resolution 5 μV
Accuracy ±0.01 %FSR
Memory 1,000,000 readings
330,000 in enhanced start/stop mode
Wrap Around Yes
Reading Rate 4 readings every second (4Hz) to 1 every 24 hours
LED Indicator Red & Green
Channels 1
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 10 years at a 15 minute reading rate
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),
0 to 95%RH non–condensing
Material ABS plastic
Dimensions 1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Weight 0.9 oz (24 g)
Approvals CE
Range 2.5 V 15 V 30 V
Measurement Range (VDC) -3 to +3 V -8 to +24 V -8 to +32 V
Accuracy +0.05%FSR
Resolution (mV) 0.1 mV 0.5 mV 1.0 mV
Overload Protection +50 V, indefinitely
*Volt101A Range, Resolution and Calibrated Accuracy
Product User Guide
www. .com information@itm.com1.800.561.8187
Wiring the Data Logger
Volt101A, 2.5V, 15V and 30V models
Single Ended Wiring
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
Product Notes
LEDs
- Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start
mode
- Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to
indicate an alarm condition
Engineering Units
Native measurement units can be scaled to display measurement units of another type.
This is useful when monitoring voltage outputs from different types of sensors such as
temperature, CO2, flow rate and more. Please refer to the application note “Engineering
Units”, found on the MadgeTech website, for information on how to manage Engineering
Units. Also view the Engineering Units Video for step-by-step setup instructions.
Password Protection
An optional password may be programmed into the device to restrict access to
configuration options. Data may be read out without the password.
Multiple Start/Stop Mode Activation
- To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash
during this time. The device has started logging.
- To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash
during this time. The device has stopped logging.
Alarm
User selectable high and low voltage limits.
Installation Guide
Installing the Interface cable
- IFC200: Insert the device into a USB port. The drivers will install automatically.
Product User Guide
Volt101A and Volt101A-160mVDC
Device Operation
Starting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer.
- The device will appear in the Connected Devices list, highlight the desired data logger.
- For most applications, select “Custom Start” from the menu bar and choose the desired
start method, reading rate and other parameters appropriate for the data logging
application and click “Start”. (“Quick Start” applies the most recent custom start options,
“Batch Start” is used for managing multiple loggers at once, “Real Time Start” stores the
dataset as it records while connected to the logger.)
- The status of the device will change to “Running”, “Waiting to Start” or “Waiting to
Manual Start”, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Highlight the data logger in the Connected Devices list. Click “Stop” on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click “Download”. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials: Small Phillips Head Screwdriver & Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The Volt101A and Volt101A-160 standard calibration depends on the range.
Additional Services:
Custom calibration and verification point options available, please call for pricing.
+ Input
- Input
Ground
Connector for interface cable
Two-position removable screw terminal
connections; accepts 2-wire configurations.
Volt101A-160mVDC
Differential Wiring
Three position removable screw terminal
connections, accepts 3 wire configurations.
Voltage 160 mV 2.5 V 15 V 30 V
Range 0 V and 90-160 mV 0 V and 2.25-2.5 V 0 V and 13.5-15 V 0 V and 27-30 V
www. .com information@itm.com1.800.561.8187

This manual suits for next models

5

Other MadgeTech Data Logger manuals

MadgeTech MicroTemp Specification sheet

MadgeTech

MadgeTech MicroTemp Specification sheet

MadgeTech Bridge101A-30 User manual

MadgeTech

MadgeTech Bridge101A-30 User manual

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech Pulse101A Specification sheet

MadgeTech

MadgeTech Pulse101A Specification sheet

MadgeTech HiTemp140-PT Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Specification sheet

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech TSR101-5 User manual

MadgeTech

MadgeTech TSR101-5 User manual

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech PRTC110 User manual

MadgeTech

MadgeTech PRTC110 User manual

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech Cryo-Temp User manual

MadgeTech

MadgeTech Cryo-Temp User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech PRTemp1000 Specification sheet

MadgeTech

MadgeTech PRTemp1000 Specification sheet

MadgeTech TSR101-EB User manual

MadgeTech

MadgeTech TSR101-EB User manual

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

MadgeTech Shock101-50 Specification sheet

MadgeTech

MadgeTech Shock101-50 Specification sheet

MadgeTech UltraShock Specification sheet

MadgeTech

MadgeTech UltraShock Specification sheet

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech CryoTemp Specification sheet

MadgeTech

MadgeTech CryoTemp Specification sheet

Popular Data Logger manuals by other brands

Magnetek DataLogger 4 Series quick start guide

Magnetek

Magnetek DataLogger 4 Series quick start guide

Corintech FilesThruTheAir 21CFR quick start guide

Corintech

Corintech FilesThruTheAir 21CFR quick start guide

APAR AR200 User instruction

APAR

APAR AR200 User instruction

GHM Delta OHM HD50CR-AS operating manual

GHM

GHM Delta OHM HD50CR-AS operating manual

Martin Lishman TuberLog Instruction manual and users guide

Martin Lishman

Martin Lishman TuberLog Instruction manual and users guide

PASCO Pasport SPARKlink Air PS-2011 reference guide

PASCO

PASCO Pasport SPARKlink Air PS-2011 reference guide

Giacomini GE552Y051 quick start guide

Giacomini

Giacomini GE552Y051 quick start guide

Huawei SmartLogger1000 user manual

Huawei

Huawei SmartLogger1000 user manual

AEMC instruments 1246 quick start guide

AEMC instruments

AEMC instruments 1246 quick start guide

Racelogic VBOX Mini user manual

Racelogic

Racelogic VBOX Mini user manual

KYOWA SME Series instruction manual

KYOWA

KYOWA SME Series instruction manual

Cryopak Contactless Temperature Logger Detailed user guide

Cryopak

Cryopak Contactless Temperature Logger Detailed user guide

Skye DATAHOG 2 instructions

Skye

Skye DATAHOG 2 instructions

Omega OMB-DAQ-2408 Series user guide

Omega

Omega OMB-DAQ-2408 Series user guide

CyberPower CPSDL02 user manual

CyberPower

CyberPower CPSDL02 user manual

FLIR EXTECH INSTRUMENTS DL150 user guide

FLIR

FLIR EXTECH INSTRUMENTS DL150 user guide

Chauvin Arnoux PEL 51 manual

Chauvin Arnoux

Chauvin Arnoux PEL 51 manual

Racelogic Performance Box Touch V1 Installing

Racelogic

Racelogic Performance Box Touch V1 Installing

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.