Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
REV A 2011.01.07
Volt101A &
Volt101A-160
Volt101A-2.5V
2.5VDC Voltage Data Logger
Volt101A-15V
15VDC Voltage Data Logger
Volt101A-30V
30VDC Voltage Data Logger
Volt101A-160mV
+160mVDC Differential Voltage
Data Logger
Part Number Volt101A Volt101A-160mV
Range
*See Table for Details
±160mVDC
Resolution 5μV
Accuracy ±0.01%FSR
Memory 1,000,000 readings
330,000 in enhanced start/stop mode
Wrap Around Yes
Sample Rate 4 readings every second (4Hz) to 1 every 12 hours
LED Indicator Red & Green
Channels 1
Required Interface Package IFC200
Baud Rate 115,200
Typical Battery Life 10 years at a 15 minute reading rate
Operating Environment –40°C to +80°C (-40°F to +176°F),
0 to 95%RH non–condensing
Material ABS plastic
Dimensions 1.4” x 2.5” x 0.6”
(36mm x 64mm x 16mm)
Approvals CE
Range 2.5V 15V 30V
Measurement Range (VDC) -3 to +3V -8 to +24V -8 to +32V
Accuracy +0.05%FSR
Resolution (mV) 0.1mV 0.5mV 1.0mV
Overload Protection +50V, indenitely
*Volt101A Range, Resolution and Calibrated Accuracy
Product Information Card
Wiring the Data Logger
Volt101A, 2.5V, 15V and 30V models
Single Ended Wiring
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
Product Notes
LEDs
Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start mode
Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to indicate
an alarm condition
Engineering Units
Native measurement units can be scaled to display measurement units of another type.
This is useful when monitoring voltage outputs from different types of sensors such as
temperature, CO2, flow rate and more. Please refer to the application note “Engineering
Units”, found on the MadgeTech website, for information on how to manage Engineering
Units. Also view the Engineering Units Video for step-by-step setup instructions.
Password Protection
An optional password may be programmed into the device to restrict access to
configuration options. Data may be read out without the password.
Multiple Start/Stop Mode Activation
To start device: Press and hold the pushbutton and the green LED will flash twice a second.
After three seconds, the green will flash rapidly for two seconds. The device has started logging.
To stop the device: Press and hold the pushbutton and the red LED will flash twice a second.
After three seconds, red will flash rapidly for two seconds. The device has stopped logging.
Alarm
User selectable high and low voltage limits.
Installation Guide
Installing the Interface cable
- IFC200
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Click on Drivers and Third Party
Tools, then Install USB Interface Drivers. Click Install to install the USB drivers. Plug the
IFC200 cable into an available USB port on the computer.
Installing the software
Insert the Software CD in the CD Drive. If the autorun does not appear, locate the drive on
the computer and double click Autorun.exe. Follow the instructions in the Wizard.
Product Quick Reference Card
Volt101A and Volt101A-160mVDC
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place in the measurement environment
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this
point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. Data will download onto the PC.
Device Maintenance
Battery Replacement
Materials: Small Phillips Head Screwdriver & Replacement Battery (LTC-7PN)
- Puncture the center of the back label with the screw driver and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The Volt101A and Volt101A-160 standard calibration depends on the range.
Pricing:
Recalibration traceable to NIST $60.00
Recalibration $40.00
Additional Services:
As Found Data $15.00 per parameter/channel
Verification Point $15.00 per point
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
+ Input
- Input
Ground
Connector for interface cable
Two-position removable screw terminal
connections; accepts 2-wire configurations.
Volt101A-160mVDC
Differential Wiring
Three position removable screw terminal
connections, accepts 3 wire configurations.
Voltage 160mV
2.5V
15V 30V
Range 0V and 90-160mV 0V and 2.25-2.5V 0V and 13.5-15V 0V and 27-30V

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech

MadgeTech HiTemp140X2 Series Specification sheet

MadgeTech PR1000IS Series Specification sheet

MadgeTech

MadgeTech PR1000IS Series Specification sheet

MadgeTech QuadState User manual

MadgeTech

MadgeTech QuadState User manual

MadgeTech HiTemp150 User manual

MadgeTech

MadgeTech HiTemp150 User manual

MadgeTech RFpHTemp101A User manual

MadgeTech

MadgeTech RFpHTemp101A User manual

MadgeTech Temp1000S User manual

MadgeTech

MadgeTech Temp1000S User manual

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech

MadgeTech HiTemp140-FP-TSK Specification sheet

MadgeTech RFC1000 User manual

MadgeTech

MadgeTech RFC1000 User manual

MadgeTech Rain101A Specification sheet

MadgeTech

MadgeTech Rain101A Specification sheet

MadgeTech HITEMP140-PT Specification sheet

MadgeTech

MadgeTech HITEMP140-PT Specification sheet

MadgeTech octtemp 2000 User manual

MadgeTech

MadgeTech octtemp 2000 User manual

MadgeTech HiTemp140-PT User manual

MadgeTech

MadgeTech HiTemp140-PT User manual

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech ThermoVault Max Specification sheet

MadgeTech

MadgeTech ThermoVault Max Specification sheet

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech QuadVolt-100mV User manual

MadgeTech

MadgeTech QuadVolt-100mV User manual

MadgeTech HiTemp140 Series User manual

MadgeTech

MadgeTech HiTemp140 Series User manual

Popular Data Logger manuals by other brands

Thies CLIMA Datalogger DLU First steps

Thies CLIMA

Thies CLIMA Datalogger DLU First steps

NexSens X2 quick start guide

NexSens

NexSens X2 quick start guide

ICP DAS USA I-7067 quick start guide

ICP DAS USA

ICP DAS USA I-7067 quick start guide

hager HTG410H operating manual

hager

hager HTG410H operating manual

Ebro EBI-2-BUS manual

Ebro

Ebro EBI-2-BUS manual

MRC MHT-381SD Operation manual

MRC

MRC MHT-381SD Operation manual

Allen-Bradley 1770-SB user manual

Allen-Bradley

Allen-Bradley 1770-SB user manual

Resol Datalogger DL2 Mounting, connection, operation

Resol

Resol Datalogger DL2 Mounting, connection, operation

Fluke VIBXPERT 3 Getting started

Fluke

Fluke VIBXPERT 3 Getting started

Ohkura VM7000A Operation manual

Ohkura

Ohkura VM7000A Operation manual

Leviton EMB Hub Installation and operation manual

Leviton

Leviton EMB Hub Installation and operation manual

Campbell CR300 series Getting started guide

Campbell

Campbell CR300 series Getting started guide

Ebro EBI Series manual

Ebro

Ebro EBI Series manual

HyQuest Solutions iRIS 350FX user manual

HyQuest Solutions

HyQuest Solutions iRIS 350FX user manual

HBM QuantumX CX22B operating manual

HBM

HBM QuantumX CX22B operating manual

TrueTime VME-SG2 560-5608 manual

TrueTime

TrueTime VME-SG2 560-5608 manual

Keysight AP1200A user guide

Keysight

Keysight AP1200A user guide

PICO PicoLog CM3 user guide

PICO

PICO PicoLog CM3 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.