PRTemp140
High Temperature and Pressure Data Logger
Flush Top or NPT Port Top Options
Product User Guide
PRTemp140
Description PRTemp140
Pressure Sensor Strain Gauge
Pressure Range 0 bar to 5 bar
Pressure Resolution 0.0001 bar
Calibrated Accuracy ±0.03 bar (+20 °C to +140 °C)
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -20 °C to +140 °C (-4 °F to +284 °F)
Temperature Resolution 0.01 °C
Calibrated Accuracy ±0.1 °C (+20 °C to +140 °C)
Memory 32,767 readings
Reading Rate 1 reading every second up to 1 reading every 24 hours
Battery Life 2 years typical (1 minute reading rate)
Required Interface Package IFC400 or IFC406 USB docking station required
Operating System
Compatibility XP SP3/Vista/Windows 7/Windows 8
MadgeTech Software
Compatibility
Standard software version 4.2.3.0 or later
Secure software version 4.2.2.0 or later
Operating Environment -20 °C to +140 °C (-4 °F to +284 °F),
0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA
Material 316 Stainless Steel
Dimensions (Body) Flush Top: 1.98 in x 0.97 in x 0.97 in (50.2 mm x 24.6 mm x 24.6 mm)
NPT Top: 2.3 in x 0.97 in x 0.97 in (58.2 mm x 24.6 mm x 24.6 mm)
Weight Flush Top: 90 g (3.2 oz)
NPT Top: 100 g (3.5 oz)
IP Rating IP68
Approvals CE
MadgeTech, Inc.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE
IF HEATED ABOVE 150 °C (302 °F).
DOC-1298035-00 REV 1 2014.11.04
Flush Top
NPT Top
Product Notes
The PRTemp140 is a pressure and high temperature data logger all in one, created specifically
for use in autoclave validation, mapping studies and pressurized processes. Featuring the
familiar body style of the 140 series of data loggers and made of rugged stainless steel, this
dual purpose device is less than 2.5 inches in length, allowing it to fit discretely inside small
spaces. The PRTemp140 is able to measure and record temperatures from -20 °C to 140 °C,
and pressure from 0 bar to 5 bar, accommodating a wide range of applications even in the
harshest conditions.
Submergibility
The PRTemp140 is fully submersible and is rated IP68.
O-Rings
O-ring maintenance is a key factor when properly caring for the PRTemp140. The O-rings
ensure a tight seal and prevent liquid from entering the inside of the device. Please refer to
the application note “O-Rings 101: Protecting Your Data”, found on the MadgeTech website,
for information on how to prevent O-ring failure.
Note: This product is rated for use up to 140 °C. Please heed the battery warning. The product will explode if exposed to
temperatures above 140 °C.
Installation Guide
Installing the Interface cable
- IFC400 or IFC406
Refer to the “Quick Start Guide” included in the package.
Installing the software
The Software can be downloaded from the MadgeTech website at the following link: www.
madgetech.com/software-download. Follow the instructions provided in the Installation
Wizard.
Device Operation
Connecting and Starting the data logger
- Once the software is installed and running, plug the interface cable into the docking station.
- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station.
- The data logger will automatically appear under Connected Devices within the software.
- For most applications, select Custom Start from the menu bar and choose the desired start
method, reading rate and other parameters appropriate for the data logging application
and click Start. (Quick Start applies the most recent custom start options, Batch Start is used
for managing multiple loggers at once, Real Time Start stores the dataset as it records while
connected to the logger.)
- The status of the device will change to Running, Waiting to Start or Waiting to Manual
Start, depending upon your start method.
Product User Guide
PRTemp140
- Disconnect the data logger from the docking station and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable
memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Place the logger into the docking station.
- Highlight the data logger in the Connected Devices list. Click Stop on the menu bar.
- Once the data logger is stopped, with the logger highlighted, click Download. You will
be prompted to name your report.
- Downloading will offload and save all the recorded data to the PC.
Device Maintenance
Battery Replacement
Materials:
ER1425S-HT Battery
- Unscrew the bottom of the logger and remove the battery.
- Place the new battery into the logger. Note the polarity of the battery.
- Screw the cover back onto the logger.
Recalibration
The PRTemp140 standard calibration points are +30 °C and +140 °C for the temperature
channel and 1 bar, 2.5 bar and 5 bar for the pressure channel.

Other MadgeTech Data Logger manuals

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech PRTrans1000 Specification sheet

MadgeTech

MadgeTech PRTrans1000 Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech

MadgeTech HiTemp140-M12 Specification sheet

MadgeTech RHTEMP1000 Specification sheet

MadgeTech

MadgeTech RHTEMP1000 Specification sheet

MadgeTech Level1000 Specification sheet

MadgeTech

MadgeTech Level1000 Specification sheet

MadgeTech LynxPro User manual

MadgeTech

MadgeTech LynxPro User manual

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech Shock101-5-EB Specification sheet

MadgeTech

MadgeTech Shock101-5-EB Specification sheet

MadgeTech Bridge120 Series User manual

MadgeTech

MadgeTech Bridge120 Series User manual

MadgeTech HiTemp150 User manual

MadgeTech

MadgeTech HiTemp150 User manual

MadgeTech HiTemp140 Series User manual

MadgeTech

MadgeTech HiTemp140 Series User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech HITEMP140-1 Specification sheet

MadgeTech

MadgeTech HITEMP140-1 Specification sheet

MadgeTech Temp1000P User manual

MadgeTech

MadgeTech Temp1000P User manual

MadgeTech pHTemp101 User manual

MadgeTech

MadgeTech pHTemp101 User manual

MadgeTech PRHTemp2000 Specification sheet

MadgeTech

MadgeTech PRHTemp2000 Specification sheet

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech HiTemp140 Series Specification sheet

MadgeTech

MadgeTech HiTemp140 Series Specification sheet

MadgeTech PR1000EX-30A Specification sheet

MadgeTech

MadgeTech PR1000EX-30A Specification sheet

MadgeTech VFC2000 User manual

MadgeTech

MadgeTech VFC2000 User manual

MadgeTech octtemp 2000 User manual

MadgeTech

MadgeTech octtemp 2000 User manual

MadgeTech TCTemp2000 User manual

MadgeTech

MadgeTech TCTemp2000 User manual

MadgeTech PR140 User manual

MadgeTech

MadgeTech PR140 User manual

Popular Data Logger manuals by other brands

Besantek BST-DL10 Instructional manual

Besantek

Besantek BST-DL10 Instructional manual

TESTO 0572 2200 Series instruction manual

TESTO

TESTO 0572 2200 Series instruction manual

EasyLog EL-USB-1 Operation guide

EasyLog

EasyLog EL-USB-1 Operation guide

Hobo UA-003-64 manual

Hobo

Hobo UA-003-64 manual

Pego PLUSR 200 EXPERT Use and maintenance manual

Pego

Pego PLUSR 200 EXPERT Use and maintenance manual

MASERMIC LOGS50 installation manual

MASERMIC

MASERMIC LOGS50 installation manual

Lascar EL-PDF-1 Series quick start guide

Lascar

Lascar EL-PDF-1 Series quick start guide

Texas Instruments CBL Guide book

Texas Instruments

Texas Instruments CBL Guide book

Convergence Instruments NSRTW mk3 user manual

Convergence Instruments

Convergence Instruments NSRTW mk3 user manual

YOKOGAWA MW100 user manual

YOKOGAWA

YOKOGAWA MW100 user manual

Geolux SmartObserver user manual

Geolux

Geolux SmartObserver user manual

TESTO 160 TH Short instructions

TESTO

TESTO 160 TH Short instructions

Keydemon USB 2GB user guide

Keydemon

Keydemon USB 2GB user guide

Kvaser Memorator Light user guide

Kvaser

Kvaser Memorator Light user guide

Decagon Devices EM50G manual

Decagon Devices

Decagon Devices EM50G manual

EasyLog EL-SIE quick start guide

EasyLog

EasyLog EL-SIE quick start guide

Fluke 2680A user manual

Fluke

Fluke 2680A user manual

In-situ Rugged TROLL 200 quick start guide

In-situ

In-situ Rugged TROLL 200 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.