MadgeTech HITEMP140-FR Specification sheet

HITEMP140-FR
High Temperature Data Logger
with 2 inch Fast Response Probe
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Device Operation
3Device Maintenance
4Need Help?
Product User Guide | 2
HiTemp140-FR
PRODUCT USER GUIDE
Product Overview
MadgeTech has designed the HiTemp140-FR, a high
temperature data logger with an ultra-fast response time,
to record temperature during rapidly changing thermal
processes. This high temperature data logger features a
2 in x 0.0625 in diameter probe and is capable of recording
up to 4 Hz, which is 4 times faster than other data loggers
in this class. This allows the temperature sensor to quickly
adapt and accurately record temperature variations
in changing environments. Applications include oven
profiling, steam sterilization, chamber mapping, seafood
processing, flash freezing and more.
MadgeTech’s entire HiTemp140 data logger series is designed
with food grade stainless steel. The device can be placed
in environments up to 140 °C (284 °F) and the probe is
capable of measuring from -200 °C to 260 °C (-328 °F to
500 °F). The HiTemp140-FR is also available with an
optional thermal shield enclosure to extend the operating
range of the data logger to -200 °C to 250 °C (-328 °F to 482 °F).
The Trigger Settings feature of the HiTemp140-FR allows
users to configure high and low temperature thresholds
that when met or exceeded, will automatically start or stop
recording data to memory. This data logger is capable of
storing up to 65,000 date and time stamped readings and
features a nonvolatile solid state memory which retains
data even if the battery becomes discharged.
Water Resistance
The HiTemp140-FR is rated IP68 and is fully submersible. It
can be placed in environments up to 230 ft (70 m) of water.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Connect the device
into a USB port with the interface cable and install the
drivers.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download. You will be prompted to
name your report.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140-FR
PRODUCT USER GUIDE
Device Operation (cont’d)
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected devices panel, select the intended
device to change the settings.
2. On the Device tab, in the Information group, click
Properties. Users can also right-click on the device
and select Properties in the context menu.
3. Click Trigger and configure the Trigger settings.
Trigger formats are available in Window and Two Point
(bi-level) mode. Window mode allows for one range of
temperature monitoring and two point mode allows
for two ranges.
Note: This product is rated for use up to 140 °C (284 ºF). Please heed the
battery warning. The product will explode if exposed to temperatures
above 140 °C (284 ºF).
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor
when properly caring for the
HiTemp140-FR. The O-rings ensure
a tight seal and prevent liquid from
entering the inside of the device.
Please refer to the application note
O-Rings 101: Protecting Your
Data, found at madgetech.com,
for information on how to prevent
O-ring failure.
Battery Replacement
Materials: ER14250MR-145 Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to
high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C
(284 ºF). Please heed the battery warning. The
product will explode if exposed to temperatures
above 140 °C (284 ºF).
HiTemp140-FR
NEED HELP?
DOC-1300036-00 | REV 7 2020.04.21
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting:
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Disclaimer & Terms of Use
Published specifications can be used to determine maximum allowable exposure times for the HiTemp140 with Thermal
Shield at different temperatures beyond the normal operating range of the logger. Both the data logger and Thermal Shield
must be at ambient temperature (approximately 25 °C) before being placed in the extreme temperature environment.
Immediately following exposure to high temperature, the data logger should be removed from the thermal shield
(using appropriate precautions, as it could be VERY hot) OR the data logger and shield should be placed in a water bath
(approximately 25 °C) for at least 15 minutes to allow it to cool. Failing to do this may allow heat trapped in the Thermal
Shield to continue to heat the data logger to potentially unsafe levels.
If your application involves a ramp up to a temperature above 140 °C and/or any complex temperature profile that isn’t simply
a constant temperature, please contact MadgeTech to determine whether the HiTemp140 with Thermal Shield is suitable.
Please provide MadgeTech with a detailed description of your temperature profile, including temperatures, durations,
ramp times, and process media (air, steam, oil, water, etc.) If MadgeTech is unable to definitively calculate the suitability of
our product for your application, we can provide a test unit outfitted with a high temperature indicator sticker. This sticker
has an indicator dot which will turn black if exposed to temperatures above 143 °C. Apply the sticker to the bottom of the
data logger itself (not the thermal shield), remove the battery for safety, place the data logger into the thermal shield and
run the assembly through the proposed temperature program. The first indicator dot on the sticker will turn black at 143 °C. If
that happens, the HiTemp140 with thermal shield is not appropriate for the application and we will work to find a solution
that is.

Other MadgeTech Data Logger manuals

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech RFCurrent2000A Specification sheet

MadgeTech

MadgeTech RFCurrent2000A Specification sheet

MadgeTech EggTemp-RH User manual

MadgeTech

MadgeTech EggTemp-RH User manual

MadgeTech Shock101-EB-5 User manual

MadgeTech

MadgeTech Shock101-EB-5 User manual

MadgeTech Shock101-50 Specification sheet

MadgeTech

MadgeTech Shock101-50 Specification sheet

MadgeTech PR1000 Specification sheet

MadgeTech

MadgeTech PR1000 Specification sheet

MadgeTech QuadVolt User manual

MadgeTech

MadgeTech QuadVolt User manual

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech Pulse101A User manual

MadgeTech

MadgeTech Pulse101A User manual

MadgeTech Rain101A Specification sheet

MadgeTech

MadgeTech Rain101A Specification sheet

MadgeTech Cryo-Temp Specification sheet

MadgeTech

MadgeTech Cryo-Temp Specification sheet

MadgeTech TransiTemp-EC Specification sheet

MadgeTech

MadgeTech TransiTemp-EC Specification sheet

MadgeTech UltraShock-EB Specification sheet

MadgeTech

MadgeTech UltraShock-EB Specification sheet

MadgeTech HiTemp140 Series Specification sheet

MadgeTech

MadgeTech HiTemp140 Series Specification sheet

MadgeTech PRTemp1000IS Specification sheet

MadgeTech

MadgeTech PRTemp1000IS Specification sheet

MadgeTech LynxPro User manual

MadgeTech

MadgeTech LynxPro User manual

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech

MadgeTech Logicbus Temp1000Ex Specification sheet

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech

MadgeTech HiTemp140-5.25 Specification sheet

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech SciTemp140-PT Specification sheet

MadgeTech

MadgeTech SciTemp140-PT Specification sheet

MadgeTech RHTemp101 User manual

MadgeTech

MadgeTech RHTemp101 User manual

MadgeTech PRTC210 User manual

MadgeTech

MadgeTech PRTC210 User manual

MadgeTech AVS140-6 Specification sheet

MadgeTech

MadgeTech AVS140-6 Specification sheet

Popular Data Logger manuals by other brands

Global Sat DG-100 user manual

Global Sat

Global Sat DG-100 user manual

TFA 30.3181.IT instruction manual

TFA

TFA 30.3181.IT instruction manual

Klipspringer LC70000 user manual

Klipspringer

Klipspringer LC70000 user manual

LEGRAND MyHome F524 installation manual

LEGRAND

LEGRAND MyHome F524 installation manual

Hobo MX2501 quick start

Hobo

Hobo MX2501 quick start

Onset InTemp CX402-T205 quick start guide

Onset

Onset InTemp CX402-T205 quick start guide

ThermoWorks thermadata Setup manual

ThermoWorks

ThermoWorks thermadata Setup manual

SATO SK-L751-21 instruction manual

SATO

SATO SK-L751-21 instruction manual

M3 Mobile SL20 Series user manual

M3 Mobile

M3 Mobile SL20 Series user manual

Amprobe TR200-A user manual

Amprobe

Amprobe TR200-A user manual

SEF 570.77A Quick reference guide

SEF

SEF 570.77A Quick reference guide

Huato S220-T8 Series user guide

Huato

Huato S220-T8 Series user guide

YOKOGAWA SMARTDAC+ GX10 user manual

YOKOGAWA

YOKOGAWA SMARTDAC+ GX10 user manual

JRC JCY-1800 - installation guide

JRC

JRC JCY-1800 - installation guide

LogTag Recorders UTRED30-16 Product user guide

LogTag Recorders

LogTag Recorders UTRED30-16 Product user guide

Capetti Elettronica WineCap WSD15IIDIST user manual

Capetti Elettronica

Capetti Elettronica WineCap WSD15IIDIST user manual

Rockwell Automation Allen-Bredley Dynamix 2500 user manual

Rockwell Automation

Rockwell Automation Allen-Bredley Dynamix 2500 user manual

Hioki PW3365 Measurement guide

Hioki

Hioki PW3365 Measurement guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.